此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Fast Cardiac Bone SPECT-CZT in Transthyretin Cardiac Amyloidosis (PeakAmyL)

2026年5月18日 更新者:Pierre Yves MARIE、Central Hospital, Nancy, France

Fast Cardiac Bone 360° SPECT-CZT Accurately Reproduces Planar Perugini ≥ 2 Classification With High Reproducibility in Transthyretin Cardiac Amyloidosis

Transthyretin cardiac amyloidosis (ATTR-CA) is traditionally diagnosed using planar bone scintigraphy with a Perugini visual score ≥ 2. Fast cardiac CZT-SPECT will be evaluated for its ability to reproduce this classification and provide reproducible quantitative myocardial uptake metrics.

研究概览

地位

尚未招聘

详细说明

Transthyretin cardiac amyloidosis (ATTR-CA) has emerged as a major cause of infiltrative cardiomyopathy, and early diagnosis is associated with improved prognosis. ATTR is now recognized far more frequently than in the past, owing to increased clinical awareness and advances in non-invasive imaging strategies, including planar bone scintigraphy.

In the absence of monoclonal gammopathy, a Perugini grade ≥ 2 on planar bone scintigraphy constitutes a highly specific diagnostic criterion for ATTR-CA, obviating in most cases the need for endomyocardial biopsy. Consequently, planar bone scintigraphy acquired with conventional Anger cameras has become the reference method in this setting.

In recent years, full-ring cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) whole-body cameras have rapidly emerged. These systems offer enhanced image quality and count sensitivity, mainly due to the high intrinsic detection efficiency of CZT detectors and a dedicated full-ring geometry that optimizes photon collection over the patient's body or specific organs of interest. They have enabled the development of ultrafast three-dimensional acquisitions combined with SUV-based image scaling, thereby improving patient comfort and throughput, while also allowing lesion quantification.

However, the ability of rapid CZT-SPECT/CT acquisitions to accurately replicate the ATTR-CA diagnostic information obtained from standard planar imaging remains insufficiently documented. Furthermore, although CZT-SPECT/CT technology allows for precise quantification, it has not yet been established whether Standard Uptake Value (SUV) based parameters can serve as reliable and reproducible imaging biomarkers for ATTR-CA Therefore, the aim of this retrospective study will be to (i) evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters, and (ii) compare the reproducibility of these approaches.

研究类型

观察性的

注册 (估计的)

200

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不适用

取样方法

概率样本

研究人群

Retrospectively enrolled patients routinely referred for bone scintigraphy for suspected transthyretin cardiac amyloidosis (ATTR-CA) . During this period, a rapid three-dimensional CZT-SPECT cardiac acquisition was systematically attempted in addition to conventional planar imaging, depending on camera availability, for diagnostic purposes, particularly for identifying blood-pool activity and other extracardiac confounding uptake areas

描述

Inclusion Criteria:

  • Patients who were routinely referred for bone scintigraphy for suspected transthyretin cardiac amyloidosis (ATTR-CA) between April 2024 and April 2025.

Exclusion Criteria:

  • Patients who object to the use of their data

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Patients referred for bone scintigraphy for suspected ATTR-CA
Patients referred for bone scintigraphy for suspected ATTR-CA underwent a fast cardiac CZT-SPECT acquisition followed by standard whole-body planar imaging three or four hours after 99mTc-HMDP injection
Fast CZT camera bone scintigraphy and bone scintigraphy with conventional camera (standard care)

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
to evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters
大体时间:one day
Comparison between Perugini score obtained on the bone scan scintigraphy performed with CZT SPECT and performed with conventional camera
one day

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年5月30日

初级完成 (估计的)

2026年6月30日

研究完成 (估计的)

2026年7月30日

研究注册日期

首次提交

2026年5月6日

首先提交符合 QC 标准的

2026年5月18日

首次发布 (实际的)

2026年5月26日

研究记录更新

最后更新发布 (实际的)

2026年5月26日

上次提交的符合 QC 标准的更新

2026年5月18日

最后验证

2026年5月1日

更多信息

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅