Fast Cardiac Bone SPECT-CZT in Transthyretin Cardiac Amyloidosis (PeakAmyL)
Fast Cardiac Bone 360° SPECT-CZT Accurately Reproduces Planar Perugini ≥ 2 Classification With High Reproducibility in Transthyretin Cardiac Amyloidosis
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
Transthyretin cardiac amyloidosis (ATTR-CA) has emerged as a major cause of infiltrative cardiomyopathy, and early diagnosis is associated with improved prognosis. ATTR is now recognized far more frequently than in the past, owing to increased clinical awareness and advances in non-invasive imaging strategies, including planar bone scintigraphy.
In the absence of monoclonal gammopathy, a Perugini grade ≥ 2 on planar bone scintigraphy constitutes a highly specific diagnostic criterion for ATTR-CA, obviating in most cases the need for endomyocardial biopsy. Consequently, planar bone scintigraphy acquired with conventional Anger cameras has become the reference method in this setting.
In recent years, full-ring cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) whole-body cameras have rapidly emerged. These systems offer enhanced image quality and count sensitivity, mainly due to the high intrinsic detection efficiency of CZT detectors and a dedicated full-ring geometry that optimizes photon collection over the patient's body or specific organs of interest. They have enabled the development of ultrafast three-dimensional acquisitions combined with SUV-based image scaling, thereby improving patient comfort and throughput, while also allowing lesion quantification.
However, the ability of rapid CZT-SPECT/CT acquisitions to accurately replicate the ATTR-CA diagnostic information obtained from standard planar imaging remains insufficiently documented. Furthermore, although CZT-SPECT/CT technology allows for precise quantification, it has not yet been established whether Standard Uptake Value (SUV) based parameters can serve as reliable and reproducible imaging biomarkers for ATTR-CA Therefore, the aim of this retrospective study will be to (i) evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters, and (ii) compare the reproducibility of these approaches.
Tanulmány típusa
Beiratkozás (Becsült)
Kapcsolatok és helyek
Tanulmányi kapcsolat
- Név: VERONIQUE ROCH, MSc
- Telefonszám: +33 0383154276
- E-mail: v.roch@chru-nancy.fr
Tanulmányozza a kapcsolattartók biztonsági mentését
- Név: Pierre-Yves MARIE, MD,PhD
- Telefonszám: +33 0383153909
- E-mail: py.marie@chru-nancy.fr
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
- Felnőtt
- Idősebb felnőtt
Egészséges önkénteseket fogad
Mintavételi módszer
Tanulmányi populáció
Leírás
Inclusion Criteria:
- Patients who were routinely referred for bone scintigraphy for suspected transthyretin cardiac amyloidosis (ATTR-CA) between April 2024 and April 2025.
Exclusion Criteria:
- Patients who object to the use of their data
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
Kohorszok és beavatkozások
Csoport / Kohorsz |
Beavatkozás / kezelés |
|---|---|
|
Patients referred for bone scintigraphy for suspected ATTR-CA
Patients referred for bone scintigraphy for suspected ATTR-CA underwent a fast cardiac CZT-SPECT acquisition followed by standard whole-body planar imaging three or four hours after 99mTc-HMDP injection
|
Fast CZT camera bone scintigraphy and bone scintigraphy with conventional camera (standard care)
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
to evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters
Időkeret: one day
|
Comparison between Perugini score obtained on the bone scan scintigraphy performed with CZT SPECT and performed with conventional camera
|
one day
|
Együttműködők és nyomozók
Szponzor
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Becsült)
Elsődleges befejezés (Becsült)
A tanulmány befejezése (Becsült)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
- Idegrendszeri betegségek
- Neuromuszkuláris betegségek
- Anyagcsere, veleszületett hibák
- Genetikai betegségek, veleszületett
- Anyagcsere-betegségek
- Perifériás idegrendszeri betegségek
- Neurodegeneratív betegségek
- Heredodegeneratív rendellenességek, idegrendszer
- A proteosztázis hiányosságai
- Amiloid neuropátiák
- Amiloidózis, családi
- Amiloidózis
- Veleszületett, örökletes és újszülöttkori betegségek és rendellenességek
- Táplálkozási és anyagcsere-betegségek
- Amiloid neuropátiák, családi
Egyéb vizsgálati azonosító számok
- 2025PI149
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .