- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07605741
Fast Cardiac Bone SPECT-CZT in Transthyretin Cardiac Amyloidosis (PeakAmyL)
Fast Cardiac Bone 360° SPECT-CZT Accurately Reproduces Planar Perugini ≥ 2 Classification With High Reproducibility in Transthyretin Cardiac Amyloidosis
Přehled studie
Detailní popis
Transthyretin cardiac amyloidosis (ATTR-CA) has emerged as a major cause of infiltrative cardiomyopathy, and early diagnosis is associated with improved prognosis. ATTR is now recognized far more frequently than in the past, owing to increased clinical awareness and advances in non-invasive imaging strategies, including planar bone scintigraphy.
In the absence of monoclonal gammopathy, a Perugini grade ≥ 2 on planar bone scintigraphy constitutes a highly specific diagnostic criterion for ATTR-CA, obviating in most cases the need for endomyocardial biopsy. Consequently, planar bone scintigraphy acquired with conventional Anger cameras has become the reference method in this setting.
In recent years, full-ring cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) whole-body cameras have rapidly emerged. These systems offer enhanced image quality and count sensitivity, mainly due to the high intrinsic detection efficiency of CZT detectors and a dedicated full-ring geometry that optimizes photon collection over the patient's body or specific organs of interest. They have enabled the development of ultrafast three-dimensional acquisitions combined with SUV-based image scaling, thereby improving patient comfort and throughput, while also allowing lesion quantification.
However, the ability of rapid CZT-SPECT/CT acquisitions to accurately replicate the ATTR-CA diagnostic information obtained from standard planar imaging remains insufficiently documented. Furthermore, although CZT-SPECT/CT technology allows for precise quantification, it has not yet been established whether Standard Uptake Value (SUV) based parameters can serve as reliable and reproducible imaging biomarkers for ATTR-CA Therefore, the aim of this retrospective study will be to (i) evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters, and (ii) compare the reproducibility of these approaches.
Typ studie
Zápis (Odhadovaný)
Kontakty a umístění
Studijní kontakt
- Jméno: Véronique ROCH, MSc
- Telefonní číslo: +33 0383154276
- E-mail: v.roch@chru-nancy.fr
Studijní záloha kontaktů
- Jméno: Pierre-Yves MARIE, MD,PhD
- Telefonní číslo: +33 0383153909
- E-mail: py.marie@chru-nancy.fr
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Patients who were routinely referred for bone scintigraphy for suspected transthyretin cardiac amyloidosis (ATTR-CA) between April 2024 and April 2025.
Exclusion Criteria:
- Patients who object to the use of their data
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
Patients referred for bone scintigraphy for suspected ATTR-CA
Patients referred for bone scintigraphy for suspected ATTR-CA underwent a fast cardiac CZT-SPECT acquisition followed by standard whole-body planar imaging three or four hours after 99mTc-HMDP injection
|
Fast CZT camera bone scintigraphy and bone scintigraphy with conventional camera (standard care)
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
to evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters
Časové okno: one day
|
Comparison between Perugini score obtained on the bone scan scintigraphy performed with CZT SPECT and performed with conventional camera
|
one day
|
Spolupracovníci a vyšetřovatelé
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
- Nemoci nervového systému
- Neuromuskulární onemocnění
- Metabolismus, vrozené chyby
- Genetické choroby, vrozené
- Metabolické choroby
- Onemocnění periferního nervového systému
- Neurodegenerativní onemocnění
- Heredodegenerativní poruchy, nervový systém
- Nedostatky proteostázy
- Amyloidní neuropatie
- Amyloidóza, familiární
- Amyloidóza
- Vrozené, dědičné a neonatální nemoci a abnormality
- Nutriční a metabolické nemoci
- Amyloidní neuropatie, familiární
Další identifikační čísla studie
- 2025PI149
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na bone scintigraphy
-
Syarif Hidayatullah State Islamic University JakartaDokončenoRole doplňku alfakalcidolu ke snížení bolesti a COMP u pacientů s geriatrickou kolenní osteoartrózouOsteoartróza, koleno | LetitýIndonésie
-
Nesma MattarCairo UniversityZatím nenabíráme
-
Carl Zeiss Meditec AGZatím nenabírámeŠedý zákal | Rohovkový astigmatismus | Defekt rohovky | Deformace rohovky | Opacity objektivu | Implantát umělé čočky
-
MinaPharm PharmaceuticalsNeznámý