Fast Cardiac Bone SPECT-CZT in Transthyretin Cardiac Amyloidosis (PeakAmyL)
Fast Cardiac Bone 360° SPECT-CZT Accurately Reproduces Planar Perugini ≥ 2 Classification With High Reproducibility in Transthyretin Cardiac Amyloidosis
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Transthyretin cardiac amyloidosis (ATTR-CA) has emerged as a major cause of infiltrative cardiomyopathy, and early diagnosis is associated with improved prognosis. ATTR is now recognized far more frequently than in the past, owing to increased clinical awareness and advances in non-invasive imaging strategies, including planar bone scintigraphy.
In the absence of monoclonal gammopathy, a Perugini grade ≥ 2 on planar bone scintigraphy constitutes a highly specific diagnostic criterion for ATTR-CA, obviating in most cases the need for endomyocardial biopsy. Consequently, planar bone scintigraphy acquired with conventional Anger cameras has become the reference method in this setting.
In recent years, full-ring cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) whole-body cameras have rapidly emerged. These systems offer enhanced image quality and count sensitivity, mainly due to the high intrinsic detection efficiency of CZT detectors and a dedicated full-ring geometry that optimizes photon collection over the patient's body or specific organs of interest. They have enabled the development of ultrafast three-dimensional acquisitions combined with SUV-based image scaling, thereby improving patient comfort and throughput, while also allowing lesion quantification.
However, the ability of rapid CZT-SPECT/CT acquisitions to accurately replicate the ATTR-CA diagnostic information obtained from standard planar imaging remains insufficiently documented. Furthermore, although CZT-SPECT/CT technology allows for precise quantification, it has not yet been established whether Standard Uptake Value (SUV) based parameters can serve as reliable and reproducible imaging biomarkers for ATTR-CA Therefore, the aim of this retrospective study will be to (i) evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters, and (ii) compare the reproducibility of these approaches.
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: VERONIQUE ROCH, MSc
- Numéro de téléphone: +33 0383154276
- E-mail: v.roch@chru-nancy.fr
Sauvegarde des contacts de l'étude
- Nom: Pierre-Yves MARIE, MD,PhD
- Numéro de téléphone: +33 0383153909
- E-mail: py.marie@chru-nancy.fr
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Patients who were routinely referred for bone scintigraphy for suspected transthyretin cardiac amyloidosis (ATTR-CA) between April 2024 and April 2025.
Exclusion Criteria:
- Patients who object to the use of their data
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Patients referred for bone scintigraphy for suspected ATTR-CA
Patients referred for bone scintigraphy for suspected ATTR-CA underwent a fast cardiac CZT-SPECT acquisition followed by standard whole-body planar imaging three or four hours after 99mTc-HMDP injection
|
Fast CZT camera bone scintigraphy and bone scintigraphy with conventional camera (standard care)
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
to evaluate whether fast CZT-SPECT recordings can reproduce the diagnosis of ATTR-CA obtained using Perugini scoring on standard planar images, either by applying Perugini scoring to planar projections or by using quantitative parameters
Délai: one day
|
Comparison between Perugini score obtained on the bone scan scintigraphy performed with CZT SPECT and performed with conventional camera
|
one day
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Maladies du système nerveux
- Maladies neuromusculaires
- Métabolisme, erreurs innées
- Maladies génétiques, innées
- Maladies métaboliques
- Maladies du système nerveux périphérique
- Maladies neurodégénératives
- Troubles hérédodégénératifs, système nerveux
- Déficits de protéostase
- Neuropathies amyloïdes
- Amylose familiale
- Amylose
- Maladies et anomalies congénitales, héréditaires et néonatales
- Maladies nutritionnelles et métaboliques
- Neuropathies amyloïdes, familiales
Autres numéros d'identification d'étude
- 2025PI149
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .