Assessment of Endoscopic Tip Control Using a Novel Score Based on Snare Tip Soft Coagulation of ex Vivo Model (HAM STUDY)
Introduction: Colorectal cancer (CRC) is a significant global health concern, with colonoscopy being the primary screening tool for its detection and treatment. Endoscopic techniques such as snare tip soft coagulation (STSC) play a crucial role in reducing adenoma recurrence post-resection. However, assessing endoscopists' proficiency in tip control during these procedures remains challenging. This study aims to develop and validate a web-based scoring system to objectively evaluate endoscopist tip control during STSC application.
Research Questions:
- Can STSC application on an ex vivo model effectively measure endoscopic tip control across different levels of endoscopists' experience?
- Is there a correlation between tip control and endoscopists' polypectomy experience?
- Does tip control vary based on endoscopists' specialization?
- Can training on the STSC model improve endoscopists' tip control?
- Is it feasible to train an AI model using videos scored by expert raters to assess tip control?
- Can tip control be used as an objective measure to predict endoscopists' future performance?
Research Hypothesis: The investigators hypothesize that developing a model for easy tip control assessment will enable endoscopists to evaluate their proficiency and track progress. Training on the STSC model will enhance tip control, and cut-offs for tip control derived from preliminary data will be refined through this study.
研究概览
地位
详细说明
Study Endpoints: Primary endpoints include correlating STSC accuracy and speed with endoscopist expertise profiles, defining expected tip control ranges, and assessing agreement between raters. Secondary endpoints focus on evaluating improvement in tip control following training.
Methods: A prospective trial will be conducted, involving endoscopists of varying experience levels.
Participants will undergo assessments while performing STSC on the margin of a line within an ex vivo model to simulate a polypectomy defect. The assessments will be video-recorded and anonymized. After the first assessment, the participants will perform a tip control training session on the model before each subsequent assessment. A total of four assessments and three training sessions will be performed. An online application will be used by a pool of 6 expert raters to anonymously rate the videos of the STSC application and calculate the accuracy (number of correct hits over number of wrong hits) and the speed (hits/second) of tip control. No questionaries will be administered to the participants.
Statistical Methods: Statistical analysis will be performed using R software, with data collected and managed in Excel. Pseudonymized data will be stored securely on the hospital server.
Conclusion: This study outlines a comprehensive approach to evaluating endoscopist tip control during STSC application. By developing a standardized assessment tool and conducting a prospective trial, the investigators aim to improve our understanding of tip control proficiency and its implications for endoscopic practice.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Lynn Deleu
- 电话号码:+32 93321063
- 邮箱:lynn.deleu@uzgent.be
学习地点
-
-
East-Flanders
-
Ghent、East-Flanders、比利时、9000
- 招聘中
- UZ Ghent
-
接触:
- Lynn Deleu
- 电话号码:+32 93321063
- 邮箱:lynn.deleu@uzgent.be
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Digestive endoscopists at any level of training (trainee, consultant endoscopist, or advanced/interventional endoscopist)
- Signed informed consent for study participation
Exclusion Criteria:
- No signed informed consent for study participation
学习计划
研究是如何设计的?
设计细节
- 主要用途:卫生服务研究
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:STSC training
A free 3D-printed template with dye shapes is used to mark shapes on ham.
Endoscopists will then use a snare through the endoscope channel to trace blue-dyed lines with electrosurgical precision.
|
Exposure to the HAM model during self-directed learning.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Speed and accuracy of STSC
大体时间:From baseline STSC assessment (T1) through the final post-training STSC assessment (T4), assessed up to 4 weeks per participant.
|
To check the correlation of the accuracy and speed of STSC with the endoscopist's experience profile, the shape of the figure to which STSC is applied and the endoscopist's specialization. The definition of the expected range of tip control speed and accuracy for the different types of endoscopists. The definition for the cut-offs for extraordinary and poor tip control. An agreement in the STSC score between different reviewers. |
From baseline STSC assessment (T1) through the final post-training STSC assessment (T4), assessed up to 4 weeks per participant.
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- ONZ-2024-0214
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.