此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Alexis O-Ring and Charnley Retrievers and Its Effect on Contamination on Total Hip Arthroplasty

2026年5月27日 更新者:Carlos Torrens、Hospital del Mar

Alexis O-Ring and Charnley Retrievers in Total Hip Arthroplasty Surgery. Is There Any Difference in Intraoperative Contamination Rates?

Randomized, prospective, single-blind clinical trial comparing two static wound retractors - the Charnley retractor and the Alexis O-Ring retractor - in primary total hip arthroplasty (THA). The primary objective is to compare surgical site contamination rates between the two devices. Secondary objectives include comparison of incision length, surgical time, intraoperative skin lesions, and postoperative complications including periprosthetic joint infection. Patients will be randomized 1:1 to either retractor group. Surgical site contamination will be assessed through four intraoperative cultures taken at standardized timepoints. Follow-up will be conducted at 1 month postoperatively.

研究概览

研究类型

介入性

注册 (实际的)

144

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Barcelona、西班牙、08024
        • Hospital Del Mar

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Patients diagnosed with symptomatic hip osteoarthritis indicated for primary total hip arthroplasty (THA)

Exclusion Criteria:

  • Previous surgical interventions or scar tissue over the hip to be operated Subcapital femoral fractures requiring THA (non-primary indication) History of infection in any previous joint arthroplasty procedure Immunological disorders increasing the risk of periprosthetic joint infection (diagnosed immunodeficiencies, chemotherapy or immunosuppressive treatment) Advanced dementia or severe cognitive impairment precluding informed consent

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
实验性的:Alexis O-Ring retractor
Circular polyurethane wound retractor (Applied Medical, Rancho Santa Margarita, CA, USA). A rigid deep ring is placed beneath the fascia lata, and the polyurethane cylinder is rolled around the outer ring to retract wound edges and create a physical barrier between the skin and the surgical field.
有源比较器:Charnley retractor
Semi-rigid stainless steel ortostatic retractor consisting of a bow with two blades (one fixed, one adjustable). Placed around the incision at the level of the fascia lata to retract wound edges through elastic tension. Standard retractor currently used in total hip arthroplasty.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Surgical site contamination rate
大体时间:Intraoperative
Intraoperative surgical site contamination assessed through four standardized cultures: (1) subcutaneous tissue immediately after incision, (2) deep tissue (joint capsule) before arthrotomy, (3) deep tissue after placement of definitive prosthetic components, and (4) subcutaneous tissue after retractor removal.
Intraoperative

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2024年4月20日

初级完成 (实际的)

2025年5月24日

研究完成 (实际的)

2026年3月10日

研究注册日期

首次提交

2026年5月27日

首先提交符合 QC 标准的

2026年5月27日

首次发布 (实际的)

2026年6月2日

研究记录更新

最后更新发布 (实际的)

2026年6月2日

上次提交的符合 QC 标准的更新

2026年5月27日

最后验证

2026年5月1日

更多信息

与本研究相关的术语

其他研究编号

  • CHA-ALE_THR

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

No individual participant data sharing plan is foreseen for this study

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅