Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Alexis O-Ring and Charnley Retrievers and Its Effect on Contamination on Total Hip Arthroplasty

27 maggio 2026 aggiornato da: Carlos Torrens, Hospital del Mar

Alexis O-Ring and Charnley Retrievers in Total Hip Arthroplasty Surgery. Is There Any Difference in Intraoperative Contamination Rates?

Randomized, prospective, single-blind clinical trial comparing two static wound retractors - the Charnley retractor and the Alexis O-Ring retractor - in primary total hip arthroplasty (THA). The primary objective is to compare surgical site contamination rates between the two devices. Secondary objectives include comparison of incision length, surgical time, intraoperative skin lesions, and postoperative complications including periprosthetic joint infection. Patients will be randomized 1:1 to either retractor group. Surgical site contamination will be assessed through four intraoperative cultures taken at standardized timepoints. Follow-up will be conducted at 1 month postoperatively.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Effettivo)

144

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Barcelona, Spagna, 08024
        • Hospital del Mar

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Bambino
  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Descrizione

Inclusion Criteria:

  • Patients diagnosed with symptomatic hip osteoarthritis indicated for primary total hip arthroplasty (THA)

Exclusion Criteria:

  • Previous surgical interventions or scar tissue over the hip to be operated Subcapital femoral fractures requiring THA (non-primary indication) History of infection in any previous joint arthroplasty procedure Immunological disorders increasing the risk of periprosthetic joint infection (diagnosed immunodeficiencies, chemotherapy or immunosuppressive treatment) Advanced dementia or severe cognitive impairment precluding informed consent

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Alexis O-Ring retractor
Circular polyurethane wound retractor (Applied Medical, Rancho Santa Margarita, CA, USA). A rigid deep ring is placed beneath the fascia lata, and the polyurethane cylinder is rolled around the outer ring to retract wound edges and create a physical barrier between the skin and the surgical field.
Comparatore attivo: Charnley retractor
Semi-rigid stainless steel ortostatic retractor consisting of a bow with two blades (one fixed, one adjustable). Placed around the incision at the level of the fascia lata to retract wound edges through elastic tension. Standard retractor currently used in total hip arthroplasty.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Surgical site contamination rate
Lasso di tempo: Intraoperative
Intraoperative surgical site contamination assessed through four standardized cultures: (1) subcutaneous tissue immediately after incision, (2) deep tissue (joint capsule) before arthrotomy, (3) deep tissue after placement of definitive prosthetic components, and (4) subcutaneous tissue after retractor removal.
Intraoperative

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

20 aprile 2024

Completamento primario (Effettivo)

24 maggio 2025

Completamento dello studio (Effettivo)

10 marzo 2026

Date di iscrizione allo studio

Primo inviato

27 maggio 2026

Primo inviato che soddisfa i criteri di controllo qualità

27 maggio 2026

Primo Inserito (Effettivo)

2 giugno 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

2 giugno 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

27 maggio 2026

Ultimo verificato

1 maggio 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • CHA-ALE_THR

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Descrizione del piano IPD

No individual participant data sharing plan is foreseen for this study

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Alexis O-Ring Wound Retractor

Sottoscrivi