此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

3D Mapping Versus Conventional Ablation in AVNRT (MAP-AVNRT)

2026年6月1日 更新者:Soha Mahmoud Ali Elshibly、Kafrelsheikh University

Three-Dimensional Electroanatomical Mapping Versus Conventional Fluoroscopy-Guided Slow Pathway Ablation for Typical Atrioventricular Nodal Re-Entrant Tachycardia: A Prospective Randomized Study

This prospective randomized interventional study compared conventional fluoroscopy-guided slow pathway ablation versus three-dimensional electroanatomical mapping-guided ablation in patients with electrophysiologically confirmed typical atrioventricular nodal re-entrant tachycardia (AVNRT). A total of 108 patients were screened for eligibility, of whom 80 eligible patients were randomized in a 1:1 ratio to either conventional fluoroscopic ablation or 3D mapping-guided ablation. Following post-randomization dropouts, the final analysis included 38 patients in the conventional group and 36 patients in the 3D mapping group. The study evaluated fluoroscopy exposure, procedural efficacy, complete slow pathway elimination, procedural success, complications, and arrhythmia recurrence during follow-up.

研究概览

详细说明

Atrioventricular nodal re-entrant tachycardia (AVNRT) is one of the most common forms of paroxysmal supraventricular tachycardia. Catheter ablation targeting the slow AV nodal pathway is considered definitive therapy with high procedural success rates.

Conventional fluoroscopy-guided ablation mainly relies on anatomical landmarks and intracardiac electrogram interpretation. However, fluoroscopy exposure remains an important concern for both patients and operators. Three-dimensional electroanatomical mapping systems allow detailed reconstruction of the triangle of Koch and facilitate substrate-guided ablation using voltage, activation, and fractionated electrogram mapping techniques. These systems may reduce fluoroscopy exposure and improve procedural precision and efficacy.

This prospective randomized two-arm interventional study was conducted at the Cardiology Department, Kafr El-Sheikh University Hospital, between December 2023 and November 2025. A total of 108 consecutive patients with symptomatic supraventricular tachycardia suggestive of AVNRT were screened for eligibility. Following assessment according to predefined inclusion and exclusion criteria, 80 eligible patients with electrophysiologically confirmed typical AVNRT were enrolled and randomized in a 1:1 ratio to either conventional fluoroscopy-guided slow pathway ablation (Conventional group, n = 40) or three-dimensional electroanatomical mapping-guided slow pathway ablation (3D group, n = 40).

During the study period, post-randomization dropouts and exclusions occurred in both groups. Consequently, the final analysis included 38 patients in the conventional ablation group and 36 patients in the 3D mapping-guided ablation group.

In the conventional arm, ablation was performed using standard fluoroscopic anatomical landmarks and intracardiac electrogram criteria within the triangle of Koch. In the 3D mapping arm, high-density electroanatomical mapping using CARTO or EnSite X systems was performed with integrated voltage, activation, and fractionated electrogram mapping to identify optimal ablation targets.

Primary outcomes included fluoroscopy time, fluoroscopy dose, complete slow pathway elimination, and procedural success defined as non-inducibility of sustained AVNRT after ablation. Secondary outcomes included total procedure duration, number and duration of radiofrequency applications, complications, recurrence during follow-up, hospital stay duration, need for redo ablation, and predictors of complete slow pathway elimination.

研究类型

介入性

注册 (实际的)

80

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Kafr el-Sheikh Governorate
      • Kafr ash Shaykh、Kafr el-Sheikh Governorate、埃及、11355
        • Kafr Elsheikh Univfersity Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Sustained symptomatic supraventricular tachycardia with surface ECG features highly suggestive of atrioventricular nodal re-entrant tachycardia (AVNRT).
  • Electrophysiologically confirmed typical (slow-fast) AVNRT during the index electrophysiology study.
  • Ability to provide written informed consent.

Exclusion Criteria:

  • Coexisting arrhythmia requiring concurrent catheter ablation during the same procedure.
  • Non-inducible AVNRT at the time of electrophysiological study.
  • Antiarrhythmic drug use within 48 hours before the procedure or ongoing amiodarone therapy.
  • Hemodynamic instability precluding safe catheter manipulation.
  • Pregnancy.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
有源比较器:Conventional Fluoroscopy-Guided Ablation
Patients underwent conventional fluoroscopy-guided slow pathway ablation using standard anatomical landmarks and intracardiac electrogram criteria within the triangle of Koch.
Conventional fluoroscopy-guided catheter ablation of the slow AV nodal pathway using anatomical landmarks and intracardiac electrogram criteria within the triangle of Koch.
其他名称:
  • Conventional Fluoroscopy-Guided Ablation
实验性的:3D Electroanatomical Mapping-Guided Ablation
Patients underwent three-dimensional electroanatomical mapping-guided slow pathway ablation using CARTO or EnSite X systems with integrated voltage, activation, and fractionated electrogram mapping.
Three-dimensional electroanatomical mapping-guided catheter ablation of the slow AV nodal pathway using CARTO or EnSite X systems with voltage and activation mapping guidance.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Total Fluoroscopy Radiation Dose During Catheter Ablation
大体时间:At completion of the index ablation procedure
Total fluoroscopy radiation dose measured during the catheter ablation procedure, reported in mGy.
At completion of the index ablation procedure
Total Fluoroscopy Exposure Time During Catheter Ablation
大体时间:At completion of the index ablation procedure
Total duration of fluoroscopy exposure during the catheter ablation procedure, reported in minutes.
At completion of the index ablation procedure

次要结果测量

结果测量
措施说明
大体时间
Number of Participants With Complete Slow Pathway Elimination
大体时间:At completion of the index ablation procedure
Complete abolition of slow pathway conduction and disappearance of the anterograde AH jump following catheter ablation.
At completion of the index ablation procedure
Number of Participants with Acute Procedural Success
大体时间:At completion of the index ablation procedure
Acute procedural success defined as non-inducibility of sustained AVNRT after catheter ablation under baseline conditions and following isoproterenol infusion.
At completion of the index ablation procedure

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2023年12月30日

初级完成 (实际的)

2025年11月23日

研究完成 (实际的)

2025年11月23日

研究注册日期

首次提交

2026年5月23日

首先提交符合 QC 标准的

2026年6月1日

首次发布 (实际的)

2026年6月5日

研究记录更新

最后更新发布 (实际的)

2026年6月5日

上次提交的符合 QC 标准的更新

2026年6月1日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

IPD 计划说明

Individual participant data (IPD) sharing plans have not yet been finalized at the time of study registration.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅