WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection
A Prospective, Multicenter, Randomized Controlled Study to Evaluate the Safety and Efficacy of the WeFlow-EndoSeal™ Aorta Vascular Plug System Combined With TEVAR for the Treatment of Stanford Type B Aortic Dissection
The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are:
Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks.
Participants will:
Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation
研究概览
地位
条件
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Huang Jin Jing
- 电话号码:13916287877
- 邮箱:jingjing.huang@endonom.com
学习地点
-
-
Beijing Municipality
-
Beijing、Beijing Municipality、中国、100853
- 招聘中
- First Medical Center of The Chinese PLA General Hospital
-
接触:
- Guo Wei
- 电话号码:+86 13910758706
- 邮箱:Pla301dml@vip.sina.com
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Patients aged 18 to 80 years old.
- Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.
- Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..
- Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.
- Patients are able to understand the purpose of the trial, participate in this study voluntarily, has signed the informed consent form personally or via their legal representative, and is willing to complete follow-up in accordance with the protocol requirements.
Exclusion Criteria:
- Presence of persistent malperfusion of visceral arterial branches caused by dissection.
- ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.
- Infectious aortic disease, Takayasu's arteritis, Marfan syndrome (or other connective tissue diseases).
- Acute systemic infection.
- History of myocardial infarction, TIA, or stroke within the past 3 months.
- NYHA Class IV cardiac dysfunction (see Appendix 1 of the protocol) or LVEF < 30%.
- Hematologic abnormalities, defined as: leukopenia (WBC < 3×10⁹/L), anemia (Hb < 90 g/L); coagulopathy, thrombocytopenia (PLT count < 50×10⁹/L).
- Renal insufficiency with serum creatinine > 221 μmol/L (or 2.5 mg/dL) and/or end-stage renal disease requiring renal dialysis, as determined by the investigator after comprehensive assessment.
- Severe hepatic insufficiency: alanine aminotransferase (ALT) or aspartate aminotransferase (AST) > 5× upper limit of normal; serum total bilirubin (STB) > 2× upper limit of normal.
- Hypersensitivity to contrast media, materials of the Aorta Vascular Plug, or the delivery system.
- Female subjects who are pregnant or breastfeeding.
- Concurrent participation in another clinical trial of drugs or devices.
- Patients with a life expectancy of less than 12 months (e.g., advanced malignant tumor).
- Any other medical conditions or abnormalities that, in the investigator's opinion, render the subject ineligible for this study.
Intraoperative Angiography Exclusion Criteria
After completion of the stent-graft procedure (including implantation of stents for the proximal and/or distal tears as necessary), DSA angiography revealed:
- Presence of other vascular lesions (e.g., coronary, renal, mesenteric arteries, etc.) requiring intervention, resulting in an impact on the postoperative medical regimen.
- Proximal Type I endoleak or Type III endoleak.
- Presence of a tear in the descending aorta above the upper margin of the celiac trunk ostium.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:test group
The test group will be treated with the WeFlow-EndoSeal™ Aorta Vascular Plug System developed and produced by Hangzhou Endonom Medtech Co., Ltd.
combined with TEVAR for patients with Stanford Type B aortic dissection
|
WeFlow-EndoSeal™ Aorta Vascular Plug System
Thoracic Endovascular Aortic Repair(TEVAR)
|
|
有源比较器:control group
The control group will receive conventional TEVAR treatment in accordance with guidelines and expert consensus.
|
Thoracic Endovascular Aortic Repair(TEVAR)
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
The 12-month Clinical Success Rate
大体时间:12 months postoperatively
|
12 months postoperatively
|
|
|
Incidence of freedom from major adverse events within 30 days postoperatively.
大体时间:30 days postoperatively
|
Freedom from all-cause death, aortic rupture, myocardial infarction, renal failure, respiratory failure, ischemic stroke, intestinal necrosis, severe lower extremity ischemia or necrosis, and paraplegia within 30 days postoperatively.
|
30 days postoperatively
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Immediate Technical Success Rate in the Test Group
大体时间:Intraoperative
|
Immediate technical success is defined as successful delivery of the Aorta Vascular Plug to the intended position, accurate positioning and successful deployment, with the delivery sheath safely withdrawn outside the body, and no conversion to open surgery.
|
Intraoperative
|
|
Thrombosis Status of the False Lumen in the Descending Thoracic Aorta
大体时间:30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the thrombosis status of the false lumen in the descending thoracic aorta (no thrombosis / partial thrombosis / complete thrombosis).
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Change in the Maximum Diameter of the Descending Thoracic Aorta
大体时间:30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Compare the CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in the maximum diameter of the descending thoracic aorta.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Change in Volume in the Descending Thoracic Aorta
大体时间:30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in true lumen, false lumen and total volume above the celiac trunk in the descending thoracic aorta.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Rate of Secondary Surgical Intervention
大体时间:30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Secondary surgical intervention refers to open or endovascular reinterventions performed on subjects due to procedure-related and device-related complications or adverse events, including but not limited to aortic rupture, migration of the Aorta Vascular Plug, infection, etc. Secondary surgical intervention does not include scheduled elective procedures or non-aortic surgeries.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Migration of the Aorta Vascular Plug
大体时间:6 months, 12 months, and 24-60 months postoperatively
|
Device migration is defined as displacement of the Aorta Vascular Plug by more than 10 mm at 6 months, 12 months, and 24-60 months postoperatively compared with that at 30 days postoperatively.
|
6 months, 12 months, and 24-60 months postoperatively
|
|
All-cause mortality, aortic dissection-related mortality, incidence of serious adverse events, and incidence of device-related adverse events.
大体时间:30 days, 6 months, 12 months, and 24-60 months postoperatively.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively.
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.