Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection

14 de junho de 2026 atualizado por: Hangzhou Endonom Medtech Co., Ltd.

A Prospective, Multicenter, Randomized Controlled Study to Evaluate the Safety and Efficacy of the WeFlow-EndoSeal™ Aorta Vascular Plug System Combined With TEVAR for the Treatment of Stanford Type B Aortic Dissection

The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are:

Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks.

Participants will:

Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Estimado)

256

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

    • Beijing Municipality
      • Beijing, Beijing Municipality, China, 100853
        • Recrutamento
        • First Medical Center of The Chinese PLA General Hospital
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  1. Patients aged 18 to 80 years old.
  2. Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.
  3. Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..
  4. Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.
  5. Patients are able to understand the purpose of the trial, participate in this study voluntarily, has signed the informed consent form personally or via their legal representative, and is willing to complete follow-up in accordance with the protocol requirements.

Exclusion Criteria:

  1. Presence of persistent malperfusion of visceral arterial branches caused by dissection.
  2. ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.
  3. Infectious aortic disease, Takayasu's arteritis, Marfan syndrome (or other connective tissue diseases).
  4. Acute systemic infection.
  5. History of myocardial infarction, TIA, or stroke within the past 3 months.
  6. NYHA Class IV cardiac dysfunction (see Appendix 1 of the protocol) or LVEF < 30%.
  7. Hematologic abnormalities, defined as: leukopenia (WBC < 3×10⁹/L), anemia (Hb < 90 g/L); coagulopathy, thrombocytopenia (PLT count < 50×10⁹/L).
  8. Renal insufficiency with serum creatinine > 221 μmol/L (or 2.5 mg/dL) and/or end-stage renal disease requiring renal dialysis, as determined by the investigator after comprehensive assessment.
  9. Severe hepatic insufficiency: alanine aminotransferase (ALT) or aspartate aminotransferase (AST) > 5× upper limit of normal; serum total bilirubin (STB) > 2× upper limit of normal.
  10. Hypersensitivity to contrast media, materials of the Aorta Vascular Plug, or the delivery system.
  11. Female subjects who are pregnant or breastfeeding.
  12. Concurrent participation in another clinical trial of drugs or devices.
  13. Patients with a life expectancy of less than 12 months (e.g., advanced malignant tumor).
  14. Any other medical conditions or abnormalities that, in the investigator's opinion, render the subject ineligible for this study.

Intraoperative Angiography Exclusion Criteria

After completion of the stent-graft procedure (including implantation of stents for the proximal and/or distal tears as necessary), DSA angiography revealed:

  1. Presence of other vascular lesions (e.g., coronary, renal, mesenteric arteries, etc.) requiring intervention, resulting in an impact on the postoperative medical regimen.
  2. Proximal Type I endoleak or Type III endoleak.
  3. Presence of a tear in the descending aorta above the upper margin of the celiac trunk ostium.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: test group
The test group will be treated with the WeFlow-EndoSeal™ Aorta Vascular Plug System developed and produced by Hangzhou Endonom Medtech Co., Ltd. combined with TEVAR for patients with Stanford Type B aortic dissection
WeFlow-EndoSeal™ Aorta Vascular Plug System
Thoracic Endovascular Aortic Repair(TEVAR)
Comparador Ativo: control group
The control group will receive conventional TEVAR treatment in accordance with guidelines and expert consensus.
Thoracic Endovascular Aortic Repair(TEVAR)

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
The 12-month Clinical Success Rate
Prazo: 12 months postoperatively
12 months postoperatively
Incidence of freedom from major adverse events within 30 days postoperatively.
Prazo: 30 days postoperatively
Freedom from all-cause death, aortic rupture, myocardial infarction, renal failure, respiratory failure, ischemic stroke, intestinal necrosis, severe lower extremity ischemia or necrosis, and paraplegia within 30 days postoperatively.
30 days postoperatively

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Immediate Technical Success Rate in the Test Group
Prazo: Intraoperative
Immediate technical success is defined as successful delivery of the Aorta Vascular Plug to the intended position, accurate positioning and successful deployment, with the delivery sheath safely withdrawn outside the body, and no conversion to open surgery.
Intraoperative
Thrombosis Status of the False Lumen in the Descending Thoracic Aorta
Prazo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the thrombosis status of the false lumen in the descending thoracic aorta (no thrombosis / partial thrombosis / complete thrombosis).
30 days, 6 months, 12 months, and 24-60 months postoperatively
Change in the Maximum Diameter of the Descending Thoracic Aorta
Prazo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare the CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in the maximum diameter of the descending thoracic aorta.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Change in Volume in the Descending Thoracic Aorta
Prazo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in true lumen, false lumen and total volume above the celiac trunk in the descending thoracic aorta.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Rate of Secondary Surgical Intervention
Prazo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Secondary surgical intervention refers to open or endovascular reinterventions performed on subjects due to procedure-related and device-related complications or adverse events, including but not limited to aortic rupture, migration of the Aorta Vascular Plug, infection, etc. Secondary surgical intervention does not include scheduled elective procedures or non-aortic surgeries.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Migration of the Aorta Vascular Plug
Prazo: 6 months, 12 months, and 24-60 months postoperatively
Device migration is defined as displacement of the Aorta Vascular Plug by more than 10 mm at 6 months, 12 months, and 24-60 months postoperatively compared with that at 30 days postoperatively.
6 months, 12 months, and 24-60 months postoperatively
All-cause mortality, aortic dissection-related mortality, incidence of serious adverse events, and incidence of device-related adverse events.
Prazo: 30 days, 6 months, 12 months, and 24-60 months postoperatively.
30 days, 6 months, 12 months, and 24-60 months postoperatively.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de junho de 2026

Conclusão Primária (Estimado)

1 de março de 2032

Conclusão do estudo (Estimado)

1 de março de 2032

Datas de inscrição no estudo

Enviado pela primeira vez

14 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

14 de junho de 2026

Primeira postagem (Real)

22 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

22 de junho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

14 de junho de 2026

Última verificação

1 de junho de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

SIM

Tipo de informação de suporte de compartilhamento de IPD

  • PROTOCOLO DE ESTUDO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever