WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection
A Prospective, Multicenter, Randomized Controlled Study to Evaluate the Safety and Efficacy of the WeFlow-EndoSeal™ Aorta Vascular Plug System Combined With TEVAR for the Treatment of Stanford Type B Aortic Dissection
The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are:
Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks.
Participants will:
Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation
Panoramica dello studio
Stato
Condizioni
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Huang Jin Jing
- Numero di telefono: 13916287877
- Email: jingjing.huang@endonom.com
Luoghi di studio
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Cina, 100853
- Reclutamento
- First Medical Center of The Chinese PLA General Hospital
-
Contatto:
- Guo Wei
- Numero di telefono: +86 13910758706
- Email: Pla301dml@vip.sina.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Patients aged 18 to 80 years old.
- Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.
- Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..
- Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.
- Patients are able to understand the purpose of the trial, participate in this study voluntarily, has signed the informed consent form personally or via their legal representative, and is willing to complete follow-up in accordance with the protocol requirements.
Exclusion Criteria:
- Presence of persistent malperfusion of visceral arterial branches caused by dissection.
- ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.
- Infectious aortic disease, Takayasu's arteritis, Marfan syndrome (or other connective tissue diseases).
- Acute systemic infection.
- History of myocardial infarction, TIA, or stroke within the past 3 months.
- NYHA Class IV cardiac dysfunction (see Appendix 1 of the protocol) or LVEF < 30%.
- Hematologic abnormalities, defined as: leukopenia (WBC < 3×10⁹/L), anemia (Hb < 90 g/L); coagulopathy, thrombocytopenia (PLT count < 50×10⁹/L).
- Renal insufficiency with serum creatinine > 221 μmol/L (or 2.5 mg/dL) and/or end-stage renal disease requiring renal dialysis, as determined by the investigator after comprehensive assessment.
- Severe hepatic insufficiency: alanine aminotransferase (ALT) or aspartate aminotransferase (AST) > 5× upper limit of normal; serum total bilirubin (STB) > 2× upper limit of normal.
- Hypersensitivity to contrast media, materials of the Aorta Vascular Plug, or the delivery system.
- Female subjects who are pregnant or breastfeeding.
- Concurrent participation in another clinical trial of drugs or devices.
- Patients with a life expectancy of less than 12 months (e.g., advanced malignant tumor).
- Any other medical conditions or abnormalities that, in the investigator's opinion, render the subject ineligible for this study.
Intraoperative Angiography Exclusion Criteria
After completion of the stent-graft procedure (including implantation of stents for the proximal and/or distal tears as necessary), DSA angiography revealed:
- Presence of other vascular lesions (e.g., coronary, renal, mesenteric arteries, etc.) requiring intervention, resulting in an impact on the postoperative medical regimen.
- Proximal Type I endoleak or Type III endoleak.
- Presence of a tear in the descending aorta above the upper margin of the celiac trunk ostium.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: test group
The test group will be treated with the WeFlow-EndoSeal™ Aorta Vascular Plug System developed and produced by Hangzhou Endonom Medtech Co., Ltd.
combined with TEVAR for patients with Stanford Type B aortic dissection
|
WeFlow-EndoSeal™ Aorta Vascular Plug System
Thoracic Endovascular Aortic Repair(TEVAR)
|
|
Comparatore attivo: control group
The control group will receive conventional TEVAR treatment in accordance with guidelines and expert consensus.
|
Thoracic Endovascular Aortic Repair(TEVAR)
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
The 12-month Clinical Success Rate
Lasso di tempo: 12 months postoperatively
|
12 months postoperatively
|
|
|
Incidence of freedom from major adverse events within 30 days postoperatively.
Lasso di tempo: 30 days postoperatively
|
Freedom from all-cause death, aortic rupture, myocardial infarction, renal failure, respiratory failure, ischemic stroke, intestinal necrosis, severe lower extremity ischemia or necrosis, and paraplegia within 30 days postoperatively.
|
30 days postoperatively
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Immediate Technical Success Rate in the Test Group
Lasso di tempo: Intraoperative
|
Immediate technical success is defined as successful delivery of the Aorta Vascular Plug to the intended position, accurate positioning and successful deployment, with the delivery sheath safely withdrawn outside the body, and no conversion to open surgery.
|
Intraoperative
|
|
Thrombosis Status of the False Lumen in the Descending Thoracic Aorta
Lasso di tempo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the thrombosis status of the false lumen in the descending thoracic aorta (no thrombosis / partial thrombosis / complete thrombosis).
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Change in the Maximum Diameter of the Descending Thoracic Aorta
Lasso di tempo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Compare the CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in the maximum diameter of the descending thoracic aorta.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Change in Volume in the Descending Thoracic Aorta
Lasso di tempo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in true lumen, false lumen and total volume above the celiac trunk in the descending thoracic aorta.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Rate of Secondary Surgical Intervention
Lasso di tempo: 30 days, 6 months, 12 months, and 24-60 months postoperatively
|
Secondary surgical intervention refers to open or endovascular reinterventions performed on subjects due to procedure-related and device-related complications or adverse events, including but not limited to aortic rupture, migration of the Aorta Vascular Plug, infection, etc. Secondary surgical intervention does not include scheduled elective procedures or non-aortic surgeries.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively
|
|
Migration of the Aorta Vascular Plug
Lasso di tempo: 6 months, 12 months, and 24-60 months postoperatively
|
Device migration is defined as displacement of the Aorta Vascular Plug by more than 10 mm at 6 months, 12 months, and 24-60 months postoperatively compared with that at 30 days postoperatively.
|
6 months, 12 months, and 24-60 months postoperatively
|
|
All-cause mortality, aortic dissection-related mortality, incidence of serious adverse events, and incidence of device-related adverse events.
Lasso di tempo: 30 days, 6 months, 12 months, and 24-60 months postoperatively.
|
30 days, 6 months, 12 months, and 24-60 months postoperatively.
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- WQ202502
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Tipo di informazioni di supporto alla condivisione IPD
- STUDIO_PROTOCOLLO
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .