Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection

14 juin 2026 mis à jour par: Hangzhou Endonom Medtech Co., Ltd.

A Prospective, Multicenter, Randomized Controlled Study to Evaluate the Safety and Efficacy of the WeFlow-EndoSeal™ Aorta Vascular Plug System Combined With TEVAR for the Treatment of Stanford Type B Aortic Dissection

The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are:

Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks.

Participants will:

Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Estimé)

256

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

    • Beijing Municipality
      • Beijing, Beijing Municipality, Chine, 100853
        • Recrutement
        • First Medical Center of The Chinese PLA General Hospital
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  1. Patients aged 18 to 80 years old.
  2. Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.
  3. Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..
  4. Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.
  5. Patients are able to understand the purpose of the trial, participate in this study voluntarily, has signed the informed consent form personally or via their legal representative, and is willing to complete follow-up in accordance with the protocol requirements.

Exclusion Criteria:

  1. Presence of persistent malperfusion of visceral arterial branches caused by dissection.
  2. ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.
  3. Infectious aortic disease, Takayasu's arteritis, Marfan syndrome (or other connective tissue diseases).
  4. Acute systemic infection.
  5. History of myocardial infarction, TIA, or stroke within the past 3 months.
  6. NYHA Class IV cardiac dysfunction (see Appendix 1 of the protocol) or LVEF < 30%.
  7. Hematologic abnormalities, defined as: leukopenia (WBC < 3×10⁹/L), anemia (Hb < 90 g/L); coagulopathy, thrombocytopenia (PLT count < 50×10⁹/L).
  8. Renal insufficiency with serum creatinine > 221 μmol/L (or 2.5 mg/dL) and/or end-stage renal disease requiring renal dialysis, as determined by the investigator after comprehensive assessment.
  9. Severe hepatic insufficiency: alanine aminotransferase (ALT) or aspartate aminotransferase (AST) > 5× upper limit of normal; serum total bilirubin (STB) > 2× upper limit of normal.
  10. Hypersensitivity to contrast media, materials of the Aorta Vascular Plug, or the delivery system.
  11. Female subjects who are pregnant or breastfeeding.
  12. Concurrent participation in another clinical trial of drugs or devices.
  13. Patients with a life expectancy of less than 12 months (e.g., advanced malignant tumor).
  14. Any other medical conditions or abnormalities that, in the investigator's opinion, render the subject ineligible for this study.

Intraoperative Angiography Exclusion Criteria

After completion of the stent-graft procedure (including implantation of stents for the proximal and/or distal tears as necessary), DSA angiography revealed:

  1. Presence of other vascular lesions (e.g., coronary, renal, mesenteric arteries, etc.) requiring intervention, resulting in an impact on the postoperative medical regimen.
  2. Proximal Type I endoleak or Type III endoleak.
  3. Presence of a tear in the descending aorta above the upper margin of the celiac trunk ostium.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: test group
The test group will be treated with the WeFlow-EndoSeal™ Aorta Vascular Plug System developed and produced by Hangzhou Endonom Medtech Co., Ltd. combined with TEVAR for patients with Stanford Type B aortic dissection
WeFlow-EndoSeal™ Aorta Vascular Plug System
Thoracic Endovascular Aortic Repair(TEVAR)
Comparateur actif: control group
The control group will receive conventional TEVAR treatment in accordance with guidelines and expert consensus.
Thoracic Endovascular Aortic Repair(TEVAR)

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
The 12-month Clinical Success Rate
Délai: 12 months postoperatively
12 months postoperatively
Incidence of freedom from major adverse events within 30 days postoperatively.
Délai: 30 days postoperatively
Freedom from all-cause death, aortic rupture, myocardial infarction, renal failure, respiratory failure, ischemic stroke, intestinal necrosis, severe lower extremity ischemia or necrosis, and paraplegia within 30 days postoperatively.
30 days postoperatively

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Immediate Technical Success Rate in the Test Group
Délai: Intraoperative
Immediate technical success is defined as successful delivery of the Aorta Vascular Plug to the intended position, accurate positioning and successful deployment, with the delivery sheath safely withdrawn outside the body, and no conversion to open surgery.
Intraoperative
Thrombosis Status of the False Lumen in the Descending Thoracic Aorta
Délai: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the thrombosis status of the false lumen in the descending thoracic aorta (no thrombosis / partial thrombosis / complete thrombosis).
30 days, 6 months, 12 months, and 24-60 months postoperatively
Change in the Maximum Diameter of the Descending Thoracic Aorta
Délai: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare the CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in the maximum diameter of the descending thoracic aorta.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Change in Volume in the Descending Thoracic Aorta
Délai: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in true lumen, false lumen and total volume above the celiac trunk in the descending thoracic aorta.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Rate of Secondary Surgical Intervention
Délai: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Secondary surgical intervention refers to open or endovascular reinterventions performed on subjects due to procedure-related and device-related complications or adverse events, including but not limited to aortic rupture, migration of the Aorta Vascular Plug, infection, etc. Secondary surgical intervention does not include scheduled elective procedures or non-aortic surgeries.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Migration of the Aorta Vascular Plug
Délai: 6 months, 12 months, and 24-60 months postoperatively
Device migration is defined as displacement of the Aorta Vascular Plug by more than 10 mm at 6 months, 12 months, and 24-60 months postoperatively compared with that at 30 days postoperatively.
6 months, 12 months, and 24-60 months postoperatively
All-cause mortality, aortic dissection-related mortality, incidence of serious adverse events, and incidence of device-related adverse events.
Délai: 30 days, 6 months, 12 months, and 24-60 months postoperatively.
30 days, 6 months, 12 months, and 24-60 months postoperatively.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 juin 2026

Achèvement primaire (Estimé)

1 mars 2032

Achèvement de l'étude (Estimé)

1 mars 2032

Dates d'inscription aux études

Première soumission

14 juin 2026

Première soumission répondant aux critères de contrôle qualité

14 juin 2026

Première publication (Réel)

22 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

22 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

14 juin 2026

Dernière vérification

1 juin 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

OUI

Type d'informations de prise en charge du partage d'IPD

  • PROTOCOLE D'ÉTUDE

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner