Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection

14. Juni 2026 aktualisiert von: Hangzhou Endonom Medtech Co., Ltd.

A Prospective, Multicenter, Randomized Controlled Study to Evaluate the Safety and Efficacy of the WeFlow-EndoSeal™ Aorta Vascular Plug System Combined With TEVAR for the Treatment of Stanford Type B Aortic Dissection

The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are:

Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks.

Participants will:

Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation

Studienübersicht

Studientyp

Interventionell

Einschreibung (Geschätzt)

256

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

    • Beijing Municipality
      • Beijing, Beijing Municipality, China, 100853
        • Rekrutierung
        • First Medical Center of The Chinese PLA General Hospital
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  1. Patients aged 18 to 80 years old.
  2. Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.
  3. Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..
  4. Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.
  5. Patients are able to understand the purpose of the trial, participate in this study voluntarily, has signed the informed consent form personally or via their legal representative, and is willing to complete follow-up in accordance with the protocol requirements.

Exclusion Criteria:

  1. Presence of persistent malperfusion of visceral arterial branches caused by dissection.
  2. ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.
  3. Infectious aortic disease, Takayasu's arteritis, Marfan syndrome (or other connective tissue diseases).
  4. Acute systemic infection.
  5. History of myocardial infarction, TIA, or stroke within the past 3 months.
  6. NYHA Class IV cardiac dysfunction (see Appendix 1 of the protocol) or LVEF < 30%.
  7. Hematologic abnormalities, defined as: leukopenia (WBC < 3×10⁹/L), anemia (Hb < 90 g/L); coagulopathy, thrombocytopenia (PLT count < 50×10⁹/L).
  8. Renal insufficiency with serum creatinine > 221 μmol/L (or 2.5 mg/dL) and/or end-stage renal disease requiring renal dialysis, as determined by the investigator after comprehensive assessment.
  9. Severe hepatic insufficiency: alanine aminotransferase (ALT) or aspartate aminotransferase (AST) > 5× upper limit of normal; serum total bilirubin (STB) > 2× upper limit of normal.
  10. Hypersensitivity to contrast media, materials of the Aorta Vascular Plug, or the delivery system.
  11. Female subjects who are pregnant or breastfeeding.
  12. Concurrent participation in another clinical trial of drugs or devices.
  13. Patients with a life expectancy of less than 12 months (e.g., advanced malignant tumor).
  14. Any other medical conditions or abnormalities that, in the investigator's opinion, render the subject ineligible for this study.

Intraoperative Angiography Exclusion Criteria

After completion of the stent-graft procedure (including implantation of stents for the proximal and/or distal tears as necessary), DSA angiography revealed:

  1. Presence of other vascular lesions (e.g., coronary, renal, mesenteric arteries, etc.) requiring intervention, resulting in an impact on the postoperative medical regimen.
  2. Proximal Type I endoleak or Type III endoleak.
  3. Presence of a tear in the descending aorta above the upper margin of the celiac trunk ostium.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: test group
The test group will be treated with the WeFlow-EndoSeal™ Aorta Vascular Plug System developed and produced by Hangzhou Endonom Medtech Co., Ltd. combined with TEVAR for patients with Stanford Type B aortic dissection
WeFlow-EndoSeal™ Aorta Vascular Plug System
Thoracic Endovascular Aortic Repair(TEVAR)
Aktiver Komparator: control group
The control group will receive conventional TEVAR treatment in accordance with guidelines and expert consensus.
Thoracic Endovascular Aortic Repair(TEVAR)

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
The 12-month Clinical Success Rate
Zeitfenster: 12 months postoperatively
12 months postoperatively
Incidence of freedom from major adverse events within 30 days postoperatively.
Zeitfenster: 30 days postoperatively
Freedom from all-cause death, aortic rupture, myocardial infarction, renal failure, respiratory failure, ischemic stroke, intestinal necrosis, severe lower extremity ischemia or necrosis, and paraplegia within 30 days postoperatively.
30 days postoperatively

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Immediate Technical Success Rate in the Test Group
Zeitfenster: Intraoperative
Immediate technical success is defined as successful delivery of the Aorta Vascular Plug to the intended position, accurate positioning and successful deployment, with the delivery sheath safely withdrawn outside the body, and no conversion to open surgery.
Intraoperative
Thrombosis Status of the False Lumen in the Descending Thoracic Aorta
Zeitfenster: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the thrombosis status of the false lumen in the descending thoracic aorta (no thrombosis / partial thrombosis / complete thrombosis).
30 days, 6 months, 12 months, and 24-60 months postoperatively
Change in the Maximum Diameter of the Descending Thoracic Aorta
Zeitfenster: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare the CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in the maximum diameter of the descending thoracic aorta.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Change in Volume in the Descending Thoracic Aorta
Zeitfenster: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in true lumen, false lumen and total volume above the celiac trunk in the descending thoracic aorta.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Rate of Secondary Surgical Intervention
Zeitfenster: 30 days, 6 months, 12 months, and 24-60 months postoperatively
Secondary surgical intervention refers to open or endovascular reinterventions performed on subjects due to procedure-related and device-related complications or adverse events, including but not limited to aortic rupture, migration of the Aorta Vascular Plug, infection, etc. Secondary surgical intervention does not include scheduled elective procedures or non-aortic surgeries.
30 days, 6 months, 12 months, and 24-60 months postoperatively
Migration of the Aorta Vascular Plug
Zeitfenster: 6 months, 12 months, and 24-60 months postoperatively
Device migration is defined as displacement of the Aorta Vascular Plug by more than 10 mm at 6 months, 12 months, and 24-60 months postoperatively compared with that at 30 days postoperatively.
6 months, 12 months, and 24-60 months postoperatively
All-cause mortality, aortic dissection-related mortality, incidence of serious adverse events, and incidence of device-related adverse events.
Zeitfenster: 30 days, 6 months, 12 months, and 24-60 months postoperatively.
30 days, 6 months, 12 months, and 24-60 months postoperatively.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. Juni 2026

Primärer Abschluss (Geschätzt)

1. März 2032

Studienabschluss (Geschätzt)

1. März 2032

Studienanmeldedaten

Zuerst eingereicht

14. Juni 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

14. Juni 2026

Zuerst gepostet (Tatsächlich)

22. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

22. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

14. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

JA

Art der unterstützenden IPD-Freigabeinformationen

  • STUDIENPROTOKOLL

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Aortendissektion Typ B

Abonnieren