Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method

July 10, 2017 updated by: Dr Mohd Shahnaz, MBBS, M Anes, University of Malaya

Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method: A Prospective Randomized Study

Background: Central venous catheter (CVC) insertion is a very common procedure in the intensive care setting. A recent international guidelines advocated the use of ultrasound for routine internal jugular CVC insertion. The needle navigation technology is a new innovation, also known as guided positioning system (GPS) which allows clinician to visualize the needle position and trajectory in real time as it approaches the target. We hypothesised that the use of GPS would increase success rate and decrease performance time in vascular access procedures.

Objectives: To compare the success, efficacy and safety of the procedure using the ultrasound guidance (UG) with conventional versus GPS method.

Methods: This was a prospective randomized controlled study in a single centre - intensive care unit. 100 patients were randomized into two groups (50 each each). Subjects would receive CVC insertion via internal jugular vein using ultrasound guidance out of plane approach by conventional versus GPS method. Outcomes measured were the procedure efficacy, safety, level of operators' experience and their satisfaction.

Study Overview

Status

Completed

Conditions

Detailed Description

Introduction Central venous catheter (CVC) insertion is a very common procedure in the intensive care setting. A recent international guideline advocates the use of ultrasound for routine internal jugular central venous catheter insertion1. The needle navigation technology is a new innovation, also known as guided positioning system (GPS) which allows clinician to visualize the needle position and trajectory in real time as it approaches the target. We hypothesised that the use of GPS would increase success rate and decrease performance time in vascular access procedures. The objectives of this study are to compare the success, efficacy and safety of central venous catheter insertion via internal jugular vein using the ultrasound guidance with conventional method versus needle navigation technology.

Methods:

This was a prospective randomized controlled study. It was conducted in a single centre - intensive care unit (ICU), University of Malaya Medical Centre, Kuala Lumpur, Malaysia from February 2016 to October 2016. The ethic committee approval was obtained from the Malaysian medical research and ethics committee, MREC at the www.nih.gov.my (NMRR-16-334-29476).

The inclusion criterion was patients in the ICU who required central venous vascular access. The exclusion criteria were refusal to participate in this study by patient or their legal representative and patient with known history of difficult central venous access at internal jugular vein (IJV). The procedure operators were doctors in anaesthesia residency program with various level of experiences classified into 3 groups: 1 to < 2 years, 2 to < 3years, 3 years and above. Simply speaking all the operators have had previous training in ultrasound guided vascular access procedure. This would ensure that patient's safety is not compromised.

Study would be proceeded after obtaining consent from patient or the next of kin. The emergency verbal consent would be taken if the next of kin was not immediately available with subsequent written consent to follow. The available operator would perform CVC insertion via IJV using ultrasound guidance out of plane approach either with conventional method or needle guidance technology.

Study Protocol:

After obtaining consent, a computer generated randomisation would be assigned to either using the conventional or GPS method. Identified operators using GPS method would receive a standard 5 minute briefing on the needle guidance technology and got to practice with the new technology using the vascular phantom (Blue Phantom Inc., Bothell, WA, USA). The operators were allowed to practice until they were ready to perform on real patient.

All procedure would be performed using the ultrasound machine, eZono 4000 with eZGuide (eZono, Jena, Germany) and linear array transducer L3-12NGS (3-12 MHz). This ultrasound machine2 has a built-in adaptive needle recognition software called eZGuide. The navigation technology of the ultrasound device is based on an electromagnetic field that communicates with a transducer and an electromagnetic sensor sheathed by a vascular access needle. Needle movements and related magnetic field variation allow navigation system to compute the locations of the transducer and needle in the three dimensional space. The ultrasound screen would display colour coded alignment of the needle and the position of the tip relative to the imaging plane (Figure 1). Superimposed on the image is the real-time electronic needle guidance system. The dashed line represents the predicted needle trajectory. The red box represents the depth that the needle will cross the plane of the ultrasound. The solid lines on either side of the dashed line represent the actual depth of the needle. The top left corner shows a diagram of the transducer-needle relation. This allowed the user to identify the correct needle trajectory, prior to puncturing the patient's skin and maintain the chosen route to the target anatomy. Operators assigned to use GPS method would have activated the eZGuide software while those performing conventionally would have the software technology turned off when using the ultrasound machine.

The procedure time was measured in seconds using a stopwatch. The performance time was defined as time measured from placing the needle on the skin to successful vessel puncture as indicated by blood withdrawn into the syringe.

Study Type

Interventional

Enrollment (Actual)

100

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Patients in the ICU who required central venous vascular access.

Exclusion Criteria:

  • Refusal to participate in this study by patient or their legal representative and patient with known history of difficult central venous access at internal jugular vein (IJV).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Conventional method
For the Conventional method of ultrasound guided central venous catheter insertion,we use the ultrasound machine, eZono 4000 and linear array transducer L3-12NGS (3-12 MHz)
Experimental: GPS method
For the GPS method, we use the ultrasound machine, eZono 4000 with built-in adaptive needle recognition software called eZGuide (eZono, Jena, Germany) and linear array transducer L3-12NGS (3-12 MHz).

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
The procedure efficacy justified by successful cannulation.
Time Frame: 0-120 seconds
The procedure efficacy justified by successful cannulation based on the performance time and number of attempts,
0-120 seconds

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Safety of procedure and complications.
Time Frame: During and within 24 hours after procedure.
The safety of the procedure by identifying any potential complications occur, i.e. secondary tissue injury, hematoma, bleeding, pneumothorax, haemothorax or arterial puncture.
During and within 24 hours after procedure.
Operators' satisfaction.
Time Frame: within 1 week
Level of operators' satisfaction.
within 1 week

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: MOHD SHAHNAZ HASAN, MBBS, University of Malaya

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

February 1, 2016

Primary Completion (Actual)

October 1, 2016

Study Completion (Actual)

October 31, 2016

Study Registration Dates

First Submitted

July 4, 2017

First Submitted That Met QC Criteria

July 10, 2017

First Posted (Actual)

July 11, 2017

Study Record Updates

Last Update Posted (Actual)

July 11, 2017

Last Update Submitted That Met QC Criteria

July 10, 2017

Last Verified

July 1, 2017

More Information

Terms related to this study

Other Study ID Numbers

  • NMRR-16-334-29476

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.