Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method

2017年7月10日 更新者:Dr Mohd Shahnaz, MBBS, M Anes、University of Malaya

Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method: A Prospective Randomized Study

Background: Central venous catheter (CVC) insertion is a very common procedure in the intensive care setting. A recent international guidelines advocated the use of ultrasound for routine internal jugular CVC insertion. The needle navigation technology is a new innovation, also known as guided positioning system (GPS) which allows clinician to visualize the needle position and trajectory in real time as it approaches the target. We hypothesised that the use of GPS would increase success rate and decrease performance time in vascular access procedures.

Objectives: To compare the success, efficacy and safety of the procedure using the ultrasound guidance (UG) with conventional versus GPS method.

Methods: This was a prospective randomized controlled study in a single centre - intensive care unit. 100 patients were randomized into two groups (50 each each). Subjects would receive CVC insertion via internal jugular vein using ultrasound guidance out of plane approach by conventional versus GPS method. Outcomes measured were the procedure efficacy, safety, level of operators' experience and their satisfaction.

調査の概要

詳細な説明

Introduction Central venous catheter (CVC) insertion is a very common procedure in the intensive care setting. A recent international guideline advocates the use of ultrasound for routine internal jugular central venous catheter insertion1. The needle navigation technology is a new innovation, also known as guided positioning system (GPS) which allows clinician to visualize the needle position and trajectory in real time as it approaches the target. We hypothesised that the use of GPS would increase success rate and decrease performance time in vascular access procedures. The objectives of this study are to compare the success, efficacy and safety of central venous catheter insertion via internal jugular vein using the ultrasound guidance with conventional method versus needle navigation technology.

Methods:

This was a prospective randomized controlled study. It was conducted in a single centre - intensive care unit (ICU), University of Malaya Medical Centre, Kuala Lumpur, Malaysia from February 2016 to October 2016. The ethic committee approval was obtained from the Malaysian medical research and ethics committee, MREC at the www.nih.gov.my (NMRR-16-334-29476).

The inclusion criterion was patients in the ICU who required central venous vascular access. The exclusion criteria were refusal to participate in this study by patient or their legal representative and patient with known history of difficult central venous access at internal jugular vein (IJV). The procedure operators were doctors in anaesthesia residency program with various level of experiences classified into 3 groups: 1 to < 2 years, 2 to < 3years, 3 years and above. Simply speaking all the operators have had previous training in ultrasound guided vascular access procedure. This would ensure that patient's safety is not compromised.

Study would be proceeded after obtaining consent from patient or the next of kin. The emergency verbal consent would be taken if the next of kin was not immediately available with subsequent written consent to follow. The available operator would perform CVC insertion via IJV using ultrasound guidance out of plane approach either with conventional method or needle guidance technology.

Study Protocol:

After obtaining consent, a computer generated randomisation would be assigned to either using the conventional or GPS method. Identified operators using GPS method would receive a standard 5 minute briefing on the needle guidance technology and got to practice with the new technology using the vascular phantom (Blue Phantom Inc., Bothell, WA, USA). The operators were allowed to practice until they were ready to perform on real patient.

All procedure would be performed using the ultrasound machine, eZono 4000 with eZGuide (eZono, Jena, Germany) and linear array transducer L3-12NGS (3-12 MHz). This ultrasound machine2 has a built-in adaptive needle recognition software called eZGuide. The navigation technology of the ultrasound device is based on an electromagnetic field that communicates with a transducer and an electromagnetic sensor sheathed by a vascular access needle. Needle movements and related magnetic field variation allow navigation system to compute the locations of the transducer and needle in the three dimensional space. The ultrasound screen would display colour coded alignment of the needle and the position of the tip relative to the imaging plane (Figure 1). Superimposed on the image is the real-time electronic needle guidance system. The dashed line represents the predicted needle trajectory. The red box represents the depth that the needle will cross the plane of the ultrasound. The solid lines on either side of the dashed line represent the actual depth of the needle. The top left corner shows a diagram of the transducer-needle relation. This allowed the user to identify the correct needle trajectory, prior to puncturing the patient's skin and maintain the chosen route to the target anatomy. Operators assigned to use GPS method would have activated the eZGuide software while those performing conventionally would have the software technology turned off when using the ultrasound machine.

The procedure time was measured in seconds using a stopwatch. The performance time was defined as time measured from placing the needle on the skin to successful vessel puncture as indicated by blood withdrawn into the syringe.

研究の種類

介入

入学 (実際)

100

段階

  • 適用できない

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Patients in the ICU who required central venous vascular access.

Exclusion Criteria:

  • Refusal to participate in this study by patient or their legal representative and patient with known history of difficult central venous access at internal jugular vein (IJV).

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
アクティブコンパレータ:Conventional method
For the Conventional method of ultrasound guided central venous catheter insertion,we use the ultrasound machine, eZono 4000 and linear array transducer L3-12NGS (3-12 MHz)
実験的:GPS method
For the GPS method, we use the ultrasound machine, eZono 4000 with built-in adaptive needle recognition software called eZGuide (eZono, Jena, Germany) and linear array transducer L3-12NGS (3-12 MHz).

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
The procedure efficacy justified by successful cannulation.
時間枠:0-120 seconds
The procedure efficacy justified by successful cannulation based on the performance time and number of attempts,
0-120 seconds

二次結果の測定

結果測定
メジャーの説明
時間枠
Safety of procedure and complications.
時間枠:During and within 24 hours after procedure.
The safety of the procedure by identifying any potential complications occur, i.e. secondary tissue injury, hematoma, bleeding, pneumothorax, haemothorax or arterial puncture.
During and within 24 hours after procedure.
Operators' satisfaction.
時間枠:within 1 week
Level of operators' satisfaction.
within 1 week

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:MOHD SHAHNAZ HASAN, MBBS、University of Malaya

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2016年2月1日

一次修了 (実際)

2016年10月1日

研究の完了 (実際)

2016年10月31日

試験登録日

最初に提出

2017年7月4日

QC基準を満たした最初の提出物

2017年7月10日

最初の投稿 (実際)

2017年7月11日

学習記録の更新

投稿された最後の更新 (実際)

2017年7月11日

QC基準を満たした最後の更新が送信されました

2017年7月10日

最終確認日

2017年7月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • NMRR-16-334-29476

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

未定

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

Conventional methodの臨床試験

購読する