Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method

10. juli 2017 opdateret af: Dr Mohd Shahnaz, MBBS, M Anes, University of Malaya

Ultrasound Guided Central Venous Vascular Access - Novel Needle Navigation Technology Compared With Conventional Method: A Prospective Randomized Study

Background: Central venous catheter (CVC) insertion is a very common procedure in the intensive care setting. A recent international guidelines advocated the use of ultrasound for routine internal jugular CVC insertion. The needle navigation technology is a new innovation, also known as guided positioning system (GPS) which allows clinician to visualize the needle position and trajectory in real time as it approaches the target. We hypothesised that the use of GPS would increase success rate and decrease performance time in vascular access procedures.

Objectives: To compare the success, efficacy and safety of the procedure using the ultrasound guidance (UG) with conventional versus GPS method.

Methods: This was a prospective randomized controlled study in a single centre - intensive care unit. 100 patients were randomized into two groups (50 each each). Subjects would receive CVC insertion via internal jugular vein using ultrasound guidance out of plane approach by conventional versus GPS method. Outcomes measured were the procedure efficacy, safety, level of operators' experience and their satisfaction.

Studieoversigt

Status

Afsluttet

Betingelser

Detaljeret beskrivelse

Introduction Central venous catheter (CVC) insertion is a very common procedure in the intensive care setting. A recent international guideline advocates the use of ultrasound for routine internal jugular central venous catheter insertion1. The needle navigation technology is a new innovation, also known as guided positioning system (GPS) which allows clinician to visualize the needle position and trajectory in real time as it approaches the target. We hypothesised that the use of GPS would increase success rate and decrease performance time in vascular access procedures. The objectives of this study are to compare the success, efficacy and safety of central venous catheter insertion via internal jugular vein using the ultrasound guidance with conventional method versus needle navigation technology.

Methods:

This was a prospective randomized controlled study. It was conducted in a single centre - intensive care unit (ICU), University of Malaya Medical Centre, Kuala Lumpur, Malaysia from February 2016 to October 2016. The ethic committee approval was obtained from the Malaysian medical research and ethics committee, MREC at the www.nih.gov.my (NMRR-16-334-29476).

The inclusion criterion was patients in the ICU who required central venous vascular access. The exclusion criteria were refusal to participate in this study by patient or their legal representative and patient with known history of difficult central venous access at internal jugular vein (IJV). The procedure operators were doctors in anaesthesia residency program with various level of experiences classified into 3 groups: 1 to < 2 years, 2 to < 3years, 3 years and above. Simply speaking all the operators have had previous training in ultrasound guided vascular access procedure. This would ensure that patient's safety is not compromised.

Study would be proceeded after obtaining consent from patient or the next of kin. The emergency verbal consent would be taken if the next of kin was not immediately available with subsequent written consent to follow. The available operator would perform CVC insertion via IJV using ultrasound guidance out of plane approach either with conventional method or needle guidance technology.

Study Protocol:

After obtaining consent, a computer generated randomisation would be assigned to either using the conventional or GPS method. Identified operators using GPS method would receive a standard 5 minute briefing on the needle guidance technology and got to practice with the new technology using the vascular phantom (Blue Phantom Inc., Bothell, WA, USA). The operators were allowed to practice until they were ready to perform on real patient.

All procedure would be performed using the ultrasound machine, eZono 4000 with eZGuide (eZono, Jena, Germany) and linear array transducer L3-12NGS (3-12 MHz). This ultrasound machine2 has a built-in adaptive needle recognition software called eZGuide. The navigation technology of the ultrasound device is based on an electromagnetic field that communicates with a transducer and an electromagnetic sensor sheathed by a vascular access needle. Needle movements and related magnetic field variation allow navigation system to compute the locations of the transducer and needle in the three dimensional space. The ultrasound screen would display colour coded alignment of the needle and the position of the tip relative to the imaging plane (Figure 1). Superimposed on the image is the real-time electronic needle guidance system. The dashed line represents the predicted needle trajectory. The red box represents the depth that the needle will cross the plane of the ultrasound. The solid lines on either side of the dashed line represent the actual depth of the needle. The top left corner shows a diagram of the transducer-needle relation. This allowed the user to identify the correct needle trajectory, prior to puncturing the patient's skin and maintain the chosen route to the target anatomy. Operators assigned to use GPS method would have activated the eZGuide software while those performing conventionally would have the software technology turned off when using the ultrasound machine.

The procedure time was measured in seconds using a stopwatch. The performance time was defined as time measured from placing the needle on the skin to successful vessel puncture as indicated by blood withdrawn into the syringe.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

100

Fase

  • Ikke anvendelig

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Patients in the ICU who required central venous vascular access.

Exclusion Criteria:

  • Refusal to participate in this study by patient or their legal representative and patient with known history of difficult central venous access at internal jugular vein (IJV).

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Conventional method
For the Conventional method of ultrasound guided central venous catheter insertion,we use the ultrasound machine, eZono 4000 and linear array transducer L3-12NGS (3-12 MHz)
Eksperimentel: GPS method
For the GPS method, we use the ultrasound machine, eZono 4000 with built-in adaptive needle recognition software called eZGuide (eZono, Jena, Germany) and linear array transducer L3-12NGS (3-12 MHz).

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
The procedure efficacy justified by successful cannulation.
Tidsramme: 0-120 seconds
The procedure efficacy justified by successful cannulation based on the performance time and number of attempts,
0-120 seconds

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Safety of procedure and complications.
Tidsramme: During and within 24 hours after procedure.
The safety of the procedure by identifying any potential complications occur, i.e. secondary tissue injury, hematoma, bleeding, pneumothorax, haemothorax or arterial puncture.
During and within 24 hours after procedure.
Operators' satisfaction.
Tidsramme: within 1 week
Level of operators' satisfaction.
within 1 week

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: MOHD SHAHNAZ HASAN, MBBS, University of Malaya

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. februar 2016

Primær færdiggørelse (Faktiske)

1. oktober 2016

Studieafslutning (Faktiske)

31. oktober 2016

Datoer for studieregistrering

Først indsendt

4. juli 2017

Først indsendt, der opfyldte QC-kriterier

10. juli 2017

Først opslået (Faktiske)

11. juli 2017

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

11. juli 2017

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

10. juli 2017

Sidst verificeret

1. juli 2017

Mere information

Begreber relateret til denne undersøgelse

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • NMRR-16-334-29476

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

UBESLUTET

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Conventional method

3
Abonner