Changes in Amblyopia Using Optical Coherence Tomography
Macular and Retinal Changes in Unilateral Amblyopia Using Optical Coherence Tomography
Study Overview
Detailed Description
Amblyopia remains an important cause of low visual acuity,affecting 2% to 6% of the general population. Unilateral amblyopia is defined as reduced best-corrected visual acuity secondary to an abnormal visual experience during the critical period of visual development. Classic causes include strabismus, anisometropia, form deprivation or a combination of these factors .
The normal postnatal reduction (apoptosis) of retinal ganglion cells is arrested in amblyopia which would cause increase in retinal nerve fiber layer thickness as hypothesized by Yen et al .This also would affect the normal maturation of the macula, including movement of Henle's fibers away from the foveola. This would result in increased foveal thickness. Furthermore, because of the reduced apoptosis of retinal ganglion cells, the thickness of the ganglion cell layer in the macula would also be increased.
Optical coherence tomography : is a non-contact and non-invasive technique that help in assessment of retina abnormalities. The high resolving power (10um - Time Domain, 5um - Spectral Domain) provides excellent detail for evaluating the vitreo-retinal interface, neurosensory retinal morphology, and the retinal pigmented epithelial-choroid complex. It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues. An infrared scanning beam is split into a sample arm (directed toward the subject) and a reference arm (directed toward a mirror). As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement. The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale. As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject. The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g. retinal thickness/volume) and qualitative morphological information.
Study Type
Enrollment (Anticipated)
Contacts and Locations
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
all cooperative patients that fulfill inclusion criteria
- Age>16 and <40 years
- Patients with unilateral amblyopia ( anisometropic , strabismic and deprivational amblyopia )
Description
Inclusion Criteria:
- Age>16 and <40 years
- Patients with unilateral amblyopia ( anisometropic , strabismic and deprivational amblyopia ) .
Exclusion Criteria:
- Age<16 and >40 years.
- Patients with structural abnormality in their eye , mentally retarded patients .
Study Plan
How is the study designed?
Design Details
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
anisometropic amblyopia
|
It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues.
An infrared scanning beam is split into a sample arm and a reference arm.
As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement.
The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale.
As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject.
The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g.
RNFL or retinal thickness/volume) and qualitative morphological information.
|
|
strabismic amblyopia
|
It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues.
An infrared scanning beam is split into a sample arm and a reference arm.
As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement.
The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale.
As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject.
The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g.
RNFL or retinal thickness/volume) and qualitative morphological information.
|
|
deprivational amblyopia
|
It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues.
An infrared scanning beam is split into a sample arm and a reference arm.
As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement.
The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale.
As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject.
The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g.
RNFL or retinal thickness/volume) and qualitative morphological information.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To measure retinal layers and macular thickness changes in cases of unilateral amblyopia using optical coherence tomography in comparison with the other sound eye.
Time Frame: from october 1st 2019 to october 1st 2020
|
Foveal thickness (mean thickness in the central 1000-μm diameter area) and central foveal thickness (mean thickness at the point of intersection of 6 radial scans) are 212 ± 20 and 182 ± 23 μm, respectively.
Macular thickness measurements were thinnest at the center of the fovea, thickest within 3-mm diameter of the center, and diminished toward the periphery of the macula.
The temporal quadrant was thinner than the nasal quadrant.
|
from october 1st 2019 to october 1st 2020
|
Collaborators and Investigators
Sponsor
Publications and helpful links
General Publications
- McKee SP, Schor CM, Steinman SB, Wilson N, Koch GG, Davis SM, Hsu-Winges C, Day SH, Chan CL, Movshon JA, et al. The classification of amblyopia on the basis of visual and oculomotor performance. Trans Am Ophthalmol Soc. 1992;90:123-44; discussion 145-8. No abstract available.
- Graham PA. Epidemiology of strabismus. Br J Ophthalmol. 1974 Mar;58(3):224-31. doi: 10.1136/bjo.58.3.224. No abstract available.
- Kiorpes L, McKee SP. Neural mechanisms underlying amblyopia. Curr Opin Neurobiol. 1999 Aug;9(4):480-6. doi: 10.1016/s0959-4388(99)80072-5.
- de Zarate BR, Tejedor J. Current concepts in the management of amblyopia. Clin Ophthalmol. 2007 Dec;1(4):403-14.
- Choi MY, Lee KM, Hwang JM, Choi DG, Lee DS, Park KH, Yu YS. Comparison between anisometropic and strabismic amblyopia using functional magnetic resonance imaging. Br J Ophthalmol. 2001 Sep;85(9):1052-6. doi: 10.1136/bjo.85.9.1052.
- Yen MY, Cheng CY, Wang AG. Retinal nerve fiber layer thickness in unilateral amblyopia. Invest Ophthalmol Vis Sci. 2004 Jul;45(7):2224-30. doi: 10.1167/iovs.03-0297.
- Hee MR, Izatt JA, Swanson EA, Huang D, Schuman JS, Lin CP, Puliafito CA, Fujimoto JG. Optical coherence tomography of the human retina. Arch Ophthalmol. 1995 Mar;113(3):325-32. doi: 10.1001/archopht.1995.01100030081025.
- Yoon SW, Park WH, Baek SH, Kong SM. Thicknesses of macular retinal layer and peripapillary retinal nerve fiber layer in patients with hyperopic anisometropic amblyopia. Korean J Ophthalmol. 2005 Mar;19(1):62-7. doi: 10.3341/kjo.2005.19.1.62.
- Yakar K, Kan E, Alan A, Alp MH, Ceylan T. Retinal Nerve Fibre Layer and Macular Thicknesses in Adults with Hyperopic Anisometropic Amblyopia. J Ophthalmol. 2015;2015:946467. doi: 10.1155/2015/946467. Epub 2015 May 7.
Study record dates
Study Major Dates
Study Start (Anticipated)
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- OCT changes in amblyopia
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Amblyopia
-
Universitat Politècnica de CatalunyaParc Sanitari Sant Joan de Déu; Hospital Mutua de TerrassaCompletedAmblyopia | Anisometropic Amblyopia | Strabismic Amblyopia | Amblyopia Occlusion | Unilateral AmblyopiaSpain
-
Boston Children's HospitalNot yet recruitingAmblyopia | Amblyopia, Anisometropic | Amblyopia Strabismic | Amblyopia UnilateralUnited States
-
Eye & ENT Hospital of Fudan UniversityActive, not recruiting
-
Baylor College of MedicineTerminatedHyperopia | High Myopia | Anisometropia | Amblyopia Isometropic | Amblyopia Bilateral | High AstigmatismUnited States
-
Vedea Healthware BVElisabeth-TweeSteden Ziekenhuis; Jeroen Bosch Ziekenhuis; Health Holland; Oogziekenhuis... and other collaboratorsActive, not recruitingAmblyopia | Amblyopia, Anisometropic | Amblyopia StrabismicNetherlands
-
Universitat Politècnica de CatalunyaHospital Mutua de TerrassaCompletedAmblyopia | Anisometropic Amblyopia | Strabismic AmblyopiaSpain
-
Alaska Blind Child DiscoveryCompletedStrabismus | Strabismic Amblyopia | Refractive AmblyopiaUnited States
-
Universitat Politècnica de CatalunyaHospital Mutua de TerrassaNot yet recruitingAnisometropic Amblyopia | Strabismic Amblyopia
-
Medical University of ViennaRecruitingAmblyopia ex Strabismus | Amblyopia ex AnisometropiaAustria
-
University of OklahomaFera Pharmaceuticals, LLCNot yet recruitingRefractory AmblyopiaUnited States
Clinical Trials on optical coherence tomography
-
University of California, IrvineBeckman Laser Institute University of California IrvineCompletedCerebral AneurysmUnited States
-
Samsung Medical CenterCompleted
-
Academisch Medisch Centrum - Universiteit van Amsterdam...CompletedTransitional Cell Carcinoma of Urinary TractNetherlands
-
Khon Kaen UniversityRecruitingRetinal Vascular | Twin Pregnancy, Antepartum Condition or Complication | Choroidal EffusionThailand
-
Kasr El Aini HospitalCompletedTractional Retinal Detachment | Diabetic Vitreous HemorrhageEgypt
-
Khon Kaen UniversityNot yet recruiting
-
The Cleveland ClinicRecruitingRefractive Errors | Keratoconus | Cornea; EctasiaUnited States
-
Centre Hospitalier Universitaire, AmiensCompletedAlzheimer Disease | Lewy Body Disease | Retina | Optical Coherence Tomography | Cortical Atrophy | Optical Coherence Tomography Angiography | Retinal Thickening | Retinal Nerve Fibres LayerFrance
-
University of NebraskaRecruitingRefractive Errors | Myopia | Optical Coherence TomographyUnited States
-
Nitin VaswaniCompletedCorneal Disease | Corneal Transplant Failure | Endothelial Corneal Dystrophy | Corneal Transplant RejectionUnited States