Changes in Amblyopia Using Optical Coherence Tomography

January 26, 2021 updated by: Alyaa mohamed yousef ahmed elkabsh, Assiut University

Macular and Retinal Changes in Unilateral Amblyopia Using Optical Coherence Tomography

There have been multiple trials to investigate the morphological changes in the macula and retinal nerve fiber layer of amblyopic eyes, due to the different published results and the lack of evident association between these changes and the patients' parameters. So, we perform this study to compare the variations in macular parameters (central thickness, average thickness, macular volume) and peripapillary thickness in different cases of amblyopic eyes versus the normal fellow eyes using spectral-domain optical coherence tomography. In addition, to estimate the relationship of optical coherence tomography variations with different defined patients' parameters (age, sex, best corrected visual acuity, spherical equivalent refractive error, and axial length).

Study Overview

Status

Unknown

Conditions

Detailed Description

Amblyopia remains an important cause of low visual acuity,affecting 2% to 6% of the general population. Unilateral amblyopia is defined as reduced best-corrected visual acuity secondary to an abnormal visual experience during the critical period of visual development. Classic causes include strabismus, anisometropia, form deprivation or a combination of these factors .

The normal postnatal reduction (apoptosis) of retinal ganglion cells is arrested in amblyopia which would cause increase in retinal nerve fiber layer thickness as hypothesized by Yen et al .This also would affect the normal maturation of the macula, including movement of Henle's fibers away from the foveola. This would result in increased foveal thickness. Furthermore, because of the reduced apoptosis of retinal ganglion cells, the thickness of the ganglion cell layer in the macula would also be increased.

Optical coherence tomography : is a non-contact and non-invasive technique that help in assessment of retina abnormalities. The high resolving power (10um - Time Domain, 5um - Spectral Domain) provides excellent detail for evaluating the vitreo-retinal interface, neurosensory retinal morphology, and the retinal pigmented epithelial-choroid complex. It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues. An infrared scanning beam is split into a sample arm (directed toward the subject) and a reference arm (directed toward a mirror). As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement. The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale. As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject. The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g. retinal thickness/volume) and qualitative morphological information.

Study Type

Observational

Enrollment (Anticipated)

28

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

16 years to 40 years (ADULT, CHILD)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

all cooperative patients that fulfill inclusion criteria

  1. Age>16 and <40 years
  2. Patients with unilateral amblyopia ( anisometropic , strabismic and deprivational amblyopia )

Description

Inclusion Criteria:

  1. Age>16 and <40 years
  2. Patients with unilateral amblyopia ( anisometropic , strabismic and deprivational amblyopia ) .

Exclusion Criteria:

  1. Age<16 and >40 years.
  2. Patients with structural abnormality in their eye , mentally retarded patients .

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
anisometropic amblyopia
It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues. An infrared scanning beam is split into a sample arm and a reference arm. As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement. The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale. As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject. The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g. RNFL or retinal thickness/volume) and qualitative morphological information.
strabismic amblyopia
It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues. An infrared scanning beam is split into a sample arm and a reference arm. As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement. The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale. As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject. The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g. RNFL or retinal thickness/volume) and qualitative morphological information.
deprivational amblyopia
It generates cross sectional images by analyzing the time delay and magnitude change of low coherence light as it is backscattered by ocular tissues. An infrared scanning beam is split into a sample arm and a reference arm. As the sample beam returns to the instrument it is correlated with the reference arm in order to determine distance and signal change via photodetector measurement. The resulting change in signal amplitude allows tissue differentiation by analysis of the reflective properties, which are matched to a false color scale. As the scanning beam moves across tissue, the sequential longitudinal signals, or A-scans, can be reassembled into a transverse scan yielding cross-sectional images, or B-scans, of the subject. The scans can then be analyzed in a variety of ways providing both empirical measurements (e.g. RNFL or retinal thickness/volume) and qualitative morphological information.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To measure retinal layers and macular thickness changes in cases of unilateral amblyopia using optical coherence tomography in comparison with the other sound eye.
Time Frame: from october 1st 2019 to october 1st 2020
Foveal thickness (mean thickness in the central 1000-μm diameter area) and central foveal thickness (mean thickness at the point of intersection of 6 radial scans) are 212 ± 20 and 182 ± 23 μm, respectively. Macular thickness measurements were thinnest at the center of the fovea, thickest within 3-mm diameter of the center, and diminished toward the periphery of the macula. The temporal quadrant was thinner than the nasal quadrant.
from october 1st 2019 to october 1st 2020

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Anticipated)

February 1, 2021

Primary Completion (Anticipated)

October 1, 2021

Study Completion (Anticipated)

October 1, 2022

Study Registration Dates

First Submitted

September 7, 2019

First Submitted That Met QC Criteria

September 13, 2019

First Posted (Actual)

September 17, 2019

Study Record Updates

Last Update Posted (Actual)

January 27, 2021

Last Update Submitted That Met QC Criteria

January 26, 2021

Last Verified

January 1, 2021

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Amblyopia

Clinical Trials on optical coherence tomography

Subscribe