The Diagnostic Accuracy of the Device Under Development MULTISCOPE (MULTISCOPE)
In Vitro Pilot Study to Assess the Diagnostic Accuracy of the Device Under Development MULTISCOPE
Conventional gastrointestinal endoscopy relies on ex vivo histopathology, a process limited by diagnostic delays and high costs. The MULTISCOPE project introduces a miniaturized (2.2 mm) endoscopic device integrating advanced optical biopsy with Cold Argon Plasma (CAP) therapy. Utilizing multimodal optical fibers, the system performs label-free, high-resolution imaging via two-photon autofluorescence and second-harmonic generation.
Simultaneously, the integrated CAP technology enables targeted oncological treatment by inducing apoptosis and cell-cycle arrest with minimal collateral damage. Given that Endoscopic Submucosal Dissection (ESD) inherently provides samples containing both neoplastic and healthy margins (5-8 mm safety zone), this platform allows for precise, real-time tissue characterization. This in vitro pilot study evaluates the system's diagnostic accuracy in discriminating between healthy and neoplastic colorectal tissues.
Study Overview
Status
Conditions
Intervention / Treatment
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: IVO BOSKOSKI
- Phone Number: +39 06 3015 6580
- Email: ivo.boskoski@policlinicogemelli.it
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Colonic or rectal neoplastic lesions resectable by endoscopic submucosal dissection (ESD)
- Age ≥ 18 years, male and female
- patients with American Society of Anesthesiologists (ASA) grades 1-3
- Signed informed consent
Exclusion Criteria:
- Severe medical comorbidities precluding endoscopy;
- Uncontrolled coagulopathy;
- Pregnancy or planned pregnancy during the period of study participation;
- Life expectancy ≤2 years, as judged by the site investigator;
- Refusal to sign the informed consent.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Patients who require endoscopy with endoscopic submucosal dissection (ESD) of the colon.
Thirty consecutive colorectal specimens resected via endoscopic submucosal dissection (ESD) will be analyzed.
Each specimen serves as an internal control, comprising both central neoplasia and healthy peripheral margins ("fried-egg" morphology).
To ensure maximum accuracy with this novel device, optical biopsies will be performed on both tissue types immediately prior to formal histopathological fixation.
ESD procedures will be conducted at the Agostino Gemelli Foundation, while optical and histopathological analyses will be centralized at the Catholic University of Rome (UCSC).
|
Protocol and Transport Colorectal ESD specimens will be resected at the Fondazione Gemelli IRCCS and immediately transported dry (without formalin) to the UCSC Pathological Anatomy Unit within 15 minutes. To ensure tissue viability, dedicated staff will coordinate the transfer directly from the endoscopy suite. Ex Vivo Analysis The MULTISCOPE device will be stationed at the UCSC facility, adjacent to the pathology lab. Upon arrival, Prof. Vincenzo Arena's team will perform multimodal fiberoptic optical biopsies on both healthy and neoplastic mucosa before proceeding with standard histopathological processing. |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic Accuracy (Area Under the ROC Curve [AUC]) of the MULTISCOPE Device for Differentiating Normal versus Neoplastic Colorectal Tissue
Time Frame: At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
The diagnostic accuracy of optical biopsies performed with the two-photon microendoscope MULTISCOPE prototype will be assessed and compared against standard ex vivo histopathology (gold standard) as the reference diagnosis. Diagnostic performance will be evaluated based on the Area Under the Receiver Operating Characteristic Curve (AUC). Optimal sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals will also be calculated using the Youden Index threshold. AUC values range from 0.5 (no discrimination) to 1.0 (perfect diagnostic accuracy). |
At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Tumor Cell Destruction Rate After Cold Atmospheric Plasma (CAP) Exposure
Time Frame: Up to 12 months (at the end of the study).
|
The therapeutic efficacy of MULTISCOPE expressed as the proportion of treated/affected cells after CAP exposure, quantified in commercial gastrointestinal tumor organoids.
|
Up to 12 months (at the end of the study).
|
Collaborators and Investigators
Investigators
- Principal Investigator: IVO BOSKOSKI, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Neoplasms by Site
- Neoplasms
- Intestinal Diseases
- Gastrointestinal Neoplasms
- Digestive System Neoplasms
- Digestive System Diseases
- Gastrointestinal Diseases
- Intestinal Neoplasms
- Rectal Diseases
- Colonic Diseases
- Colorectal Neoplasms
- Diagnostic Techniques and Procedures
- Diagnosis
- Surgical Procedures, Operative
- Minimally Invasive Surgical Procedures
- Diagnostic Techniques, Surgical
- Endoscopy, Gastrointestinal
- Endoscopy, Digestive System
- Diagnostic Techniques, Digestive System
- Endoscopy
- Digestive System Surgical Procedures
- Endoscopic Mucosal Resection
Other Study ID Numbers
- 8118 (Fred Hutch/University of Washington Cancer Consortium)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.