The Diagnostic Accuracy of the Device Under Development MULTISCOPE (MULTISCOPE)
In Vitro Pilot Study to Assess the Diagnostic Accuracy of the Device Under Development MULTISCOPE
Conventional gastrointestinal endoscopy relies on ex vivo histopathology, a process limited by diagnostic delays and high costs. The MULTISCOPE project introduces a miniaturized (2.2 mm) endoscopic device integrating advanced optical biopsy with Cold Argon Plasma (CAP) therapy. Utilizing multimodal optical fibers, the system performs label-free, high-resolution imaging via two-photon autofluorescence and second-harmonic generation.
Simultaneously, the integrated CAP technology enables targeted oncological treatment by inducing apoptosis and cell-cycle arrest with minimal collateral damage. Given that Endoscopic Submucosal Dissection (ESD) inherently provides samples containing both neoplastic and healthy margins (5-8 mm safety zone), this platform allows for precise, real-time tissue characterization. This in vitro pilot study evaluates the system's diagnostic accuracy in discriminating between healthy and neoplastic colorectal tissues.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: IVO BOSKOSKI
- Numéro de téléphone: +39 06 3015 6580
- E-mail: ivo.boskoski@policlinicogemelli.it
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Colonic or rectal neoplastic lesions resectable by endoscopic submucosal dissection (ESD)
- Age ≥ 18 years, male and female
- patients with American Society of Anesthesiologists (ASA) grades 1-3
- Signed informed consent
Exclusion Criteria:
- Severe medical comorbidities precluding endoscopy;
- Uncontrolled coagulopathy;
- Pregnancy or planned pregnancy during the period of study participation;
- Life expectancy ≤2 years, as judged by the site investigator;
- Refusal to sign the informed consent.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Patients who require endoscopy with endoscopic submucosal dissection (ESD) of the colon.
Thirty consecutive colorectal specimens resected via endoscopic submucosal dissection (ESD) will be analyzed.
Each specimen serves as an internal control, comprising both central neoplasia and healthy peripheral margins ("fried-egg" morphology).
To ensure maximum accuracy with this novel device, optical biopsies will be performed on both tissue types immediately prior to formal histopathological fixation.
ESD procedures will be conducted at the Agostino Gemelli Foundation, while optical and histopathological analyses will be centralized at the Catholic University of Rome (UCSC).
|
Protocol and Transport Colorectal ESD specimens will be resected at the Fondazione Gemelli IRCCS and immediately transported dry (without formalin) to the UCSC Pathological Anatomy Unit within 15 minutes. To ensure tissue viability, dedicated staff will coordinate the transfer directly from the endoscopy suite. Ex Vivo Analysis The MULTISCOPE device will be stationed at the UCSC facility, adjacent to the pathology lab. Upon arrival, Prof. Vincenzo Arena's team will perform multimodal fiberoptic optical biopsies on both healthy and neoplastic mucosa before proceeding with standard histopathological processing. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Diagnostic Accuracy (Area Under the ROC Curve [AUC]) of the MULTISCOPE Device for Differentiating Normal versus Neoplastic Colorectal Tissue
Délai: At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
The diagnostic accuracy of optical biopsies performed with the two-photon microendoscope MULTISCOPE prototype will be assessed and compared against standard ex vivo histopathology (gold standard) as the reference diagnosis. Diagnostic performance will be evaluated based on the Area Under the Receiver Operating Characteristic Curve (AUC). Optimal sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals will also be calculated using the Youden Index threshold. AUC values range from 0.5 (no discrimination) to 1.0 (perfect diagnostic accuracy). |
At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Tumor Cell Destruction Rate After Cold Atmospheric Plasma (CAP) Exposure
Délai: Up to 12 months (at the end of the study).
|
The therapeutic efficacy of MULTISCOPE expressed as the proportion of treated/affected cells after CAP exposure, quantified in commercial gastrointestinal tumor organoids.
|
Up to 12 months (at the end of the study).
|
Collaborateurs et enquêteurs
Les enquêteurs
- Chercheur principal: IVO BOSKOSKI, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Tumeurs par site
- Tumeurs
- Maladies intestinales
- Tumeurs gastro-intestinales
- Tumeurs du système digestif
- Maladies du système digestif
- Maladies gastro-intestinales
- Tumeurs intestinales
- Maladies rectales
- Maladies du côlon
- Tumeurs colorectales
- Techniques et procédures de diagnostic
- Diagnostic
- Procédures chirurgicales, opératoires
- Procédures chirurgicales mini-invasives
- Techniques de diagnostic, chirurgicale
- Endoscopie, gastro-intestinal
- Endoscopie, système digestif
- Techniques de diagnostic, système digestif
- Endoscopie
- Procédures chirurgicales du système digestif
- Résection des muqueuses endoscopiques
Autres numéros d'identification d'étude
- 8118 (Fred Hutch/University of Washington Cancer Consortium)
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .