- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07826611
The Diagnostic Accuracy of the Device Under Development MULTISCOPE (MULTISCOPE)
In Vitro Pilot Study to Assess the Diagnostic Accuracy of the Device Under Development MULTISCOPE
Conventional gastrointestinal endoscopy relies on ex vivo histopathology, a process limited by diagnostic delays and high costs. The MULTISCOPE project introduces a miniaturized (2.2 mm) endoscopic device integrating advanced optical biopsy with Cold Argon Plasma (CAP) therapy. Utilizing multimodal optical fibers, the system performs label-free, high-resolution imaging via two-photon autofluorescence and second-harmonic generation.
Simultaneously, the integrated CAP technology enables targeted oncological treatment by inducing apoptosis and cell-cycle arrest with minimal collateral damage. Given that Endoscopic Submucosal Dissection (ESD) inherently provides samples containing both neoplastic and healthy margins (5-8 mm safety zone), this platform allows for precise, real-time tissue characterization. This in vitro pilot study evaluates the system's diagnostic accuracy in discriminating between healthy and neoplastic colorectal tissues.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: IVO BOSKOSKI
- Numer telefonu: +39 06 3015 6580
- E-mail: ivo.boskoski@policlinicogemelli.it
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Colonic or rectal neoplastic lesions resectable by endoscopic submucosal dissection (ESD)
- Age ≥ 18 years, male and female
- patients with American Society of Anesthesiologists (ASA) grades 1-3
- Signed informed consent
Exclusion Criteria:
- Severe medical comorbidities precluding endoscopy;
- Uncontrolled coagulopathy;
- Pregnancy or planned pregnancy during the period of study participation;
- Life expectancy ≤2 years, as judged by the site investigator;
- Refusal to sign the informed consent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Patients who require endoscopy with endoscopic submucosal dissection (ESD) of the colon.
Thirty consecutive colorectal specimens resected via endoscopic submucosal dissection (ESD) will be analyzed.
Each specimen serves as an internal control, comprising both central neoplasia and healthy peripheral margins ("fried-egg" morphology).
To ensure maximum accuracy with this novel device, optical biopsies will be performed on both tissue types immediately prior to formal histopathological fixation.
ESD procedures will be conducted at the Agostino Gemelli Foundation, while optical and histopathological analyses will be centralized at the Catholic University of Rome (UCSC).
|
Protocol and Transport Colorectal ESD specimens will be resected at the Fondazione Gemelli IRCCS and immediately transported dry (without formalin) to the UCSC Pathological Anatomy Unit within 15 minutes. To ensure tissue viability, dedicated staff will coordinate the transfer directly from the endoscopy suite. Ex Vivo Analysis The MULTISCOPE device will be stationed at the UCSC facility, adjacent to the pathology lab. Upon arrival, Prof. Vincenzo Arena's team will perform multimodal fiberoptic optical biopsies on both healthy and neoplastic mucosa before proceeding with standard histopathological processing. |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Diagnostic Accuracy (Area Under the ROC Curve [AUC]) of the MULTISCOPE Device for Differentiating Normal versus Neoplastic Colorectal Tissue
Ramy czasowe: At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
The diagnostic accuracy of optical biopsies performed with the two-photon microendoscope MULTISCOPE prototype will be assessed and compared against standard ex vivo histopathology (gold standard) as the reference diagnosis. Diagnostic performance will be evaluated based on the Area Under the Receiver Operating Characteristic Curve (AUC). Optimal sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals will also be calculated using the Youden Index threshold. AUC values range from 0.5 (no discrimination) to 1.0 (perfect diagnostic accuracy). |
At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Tumor Cell Destruction Rate After Cold Atmospheric Plasma (CAP) Exposure
Ramy czasowe: Up to 12 months (at the end of the study).
|
The therapeutic efficacy of MULTISCOPE expressed as the proportion of treated/affected cells after CAP exposure, quantified in commercial gastrointestinal tumor organoids.
|
Up to 12 months (at the end of the study).
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: IVO BOSKOSKI, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
- Nowotwory według lokalizacji
- Nowotwory
- Choroby jelit
- Nowotwory przewodu pokarmowego
- Nowotwory Układu Pokarmowego
- Choroby Układu Pokarmowego
- Choroby przewodu pokarmowego
- Nowotwory jelit
- Choroby odbytu
- Choroby okrężnicy
- Nowotwory jelita grubego
- Techniki i procedury diagnostyczne
- Diagnoza
- Procedury chirurgiczne, operacyjny
- Minimalnie inwazyjne procedury chirurgiczne
- Techniki diagnostyczne, chirurgiczne
- Endoskopia, przewód pokarmowy
- Endoskopia, układ trawienny
- Techniki diagnostyczne, układ trawienny
- Endoskopia
- Procedury chirurgiczne układu trawiennego
- Endoskopowa resekcja błony śluzowej
Inne numery identyfikacyjne badania
- 8118 (Fred Hutch/University of Washington Cancer Consortium)
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .