- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT00535899
Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) (SPArKLE-AS)
Studieoversigt
Status
Betingelser
Detaljeret beskrivelse
In patients with severe aortic stenosis and LV dysfunction, 76% of patients have an improvement of ventricular function and NYHA class, after aortic valve replacement. The prognostic indicators of which patients will recover EF post-operatively, has not been fully established, but has been linked to a history of prior MI and pre-operative aortic valve area. Furthermore it is hypothesized that those ventricles that do not recover are fibrosed, either from prior MI or long standing LVH (hypertrophy).
Currently systolic and diastolic function will be measured pre-operatively with standard 2D echo and Doppler. 2D Strain and Strain rate imaging with speckle tracking is a novel method of assessing regional as well as global "contractility". This method overcomes many limitations inherent in assessing myocardial functioning with current methodology, mainly it is reproducible, objective, and is independent of myocardial translation, tethering and furthermore as speckle tracking is derived from B mode images is independent of Doppler angle.The applicability of this technology to patients with aortic valve stenosis and systolic dysfunction and its clinical significance has not been evaluated. We hypothesize that patients with reduced peak systolic strain rate and diastolic strain rates at baseline adjusted for LVEF will have poorer recovery of LVEF than those with relatively preserved strain or strain rate. As this is a pilot study, we plan to prospectively analyze 50 consecutive patients who have severe aortic stenosis and left ventricular systolic dysfunction, EF under 40% with Speckle imaging derived strain rate imaging pre and post-operatively for aortic valve replacement. This would be done as part of routine pre-operative and post-operative transthoracic echocardiography using standard views, with the exception that all studies would need to be done on the GE Vivid 7 digital ultrasound system. Speckle derived imaging data is derived from standard B mode (Grey scale images), with a frame rate of 50 f/s. 3 D images will also be obtained. Post-operative TTE's will be performed before discharge and 4-12 months+/- 30 days after discharge. Baseline characteristics will be taken from the standard pre-operative baseline study including basic 2 D valve area, EF, wall thickness and geometry, and Doppler flow data. Exclusion criteria: Patients with prior cardiac surgery including CABG or other valve replacement, more than mild mitral valve or aortic regurgitation and chronic kidney disease (Cr 1.5), emergent aortic valve replacement, or endocarditis, or CAD on LHC > 50%. Informed consent will be obtain on all patients, and they will only be included if they consent. No surgery will be delayed for purpose of the study if the proper hardware/GE VIVID system is not available.
Undersøgelsestype
Tilmelding (Forventet)
Kontakter og lokationer
Studiesteder
-
-
Ohio
-
Cleveland, Ohio, Forenede Stater, 44195
- Cleveland Clinic
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Severe aortic stenosis with ejection fraction less than 40% that is schedule to undergo aortic valve replacement
Exclusion Criteria:
- Creatinine > 2
- More than moderate mitral, tricuspid, or aortic regurgitation.
- Endocarditis
- Emergent surgery
- Prior sternotimy
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Samarbejdspartnere og efterforskere
Sponsor
Efterforskere
- Ledende efterforsker: Ryan P Daly, MD, CCF
Datoer for undersøgelser
Studer store datoer
Studiestart
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 07-578
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Aortastenose
-
Federal University of São PauloAfsluttet
-
China National Center for Cardiovascular DiseasesRekrutteringDe Novo Stenosis | Medikamentbelagt ballon | Stent til eluering af lægemidlerKina
-
IRCCS Azienda Ospedaliero-Universitaria di BolognaRekrutteringPCI | De Novo Stenosis | DCBItalien
-
Napa Pain InstituteVertos Medical, Inc.AfsluttetLumbal Spine Stenosis Central CanalForenede Stater
-
Zunyi Medical CollegeRekrutteringAkut koronarsyndrom | De Novo StenosisKina
-
Xijing HospitalAktiv, ikke rekrutterendeKoronararteriesygdom | De Novo StenosisKina
-
Genoss Co., Ltd.AfsluttetPerifer arteriesygdom | De Novo StenosisKorea, Republikken
-
Xijing HospitalAktiv, ikke rekrutterendeKoronararteriesygdom | Perkutan koronar intervention | De Novo StenosisKina
-
General Administration of Military Health, TunisiaB. Braun Medical International Trading Company Ltd.RekrutteringKoronararteriesygdom (CAD) | De Novo Stenosis | Perkutan koronar intervention (PCI)Tunesien
-
Xijing HospitalRekrutteringDe Novo Stenosis | Svært forkalkede koronare stenoserKina