- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07595601
Computer Interpretation of the ECG Raising Awareness CIERA Trial (CIERA)
The Effect of Three Educational Interventions on Emergency and Critical Nurses Proficiency in Computer Interpretation of the ECG: Results of the CIERA Trial
Background: Practice guidelines require emergency and critical care nurses (ECC) to be skillful in ECG and cardiac monitoring. Evidence suggests that nurses' proficiency is still inadequate with this regard. Computer interpretation of the ECG (CIE) is accurate and improves clinicians' accuracy in ECG interpretation. Unfortunately, nurses are not taught or trained to use this technology. Through this study the investigators aim to evaluate the effectiveness of three educational interventions to improve ECC nurses' proficiency in CIE.
Methods. The investigators applied a randomized mixed, crossover and parallel, design. Linear mixed model analysis was used to examine differences in CIE test score among groups and across time. There were three interventional groups (G0, no intervention then flyer; G1, face-to-face then online; and G2, online then face-to-face) with three points of time measurement (T0, baselines; T1, after first intervention, and T2 after second intervention).
Studienübersicht
Status
Intervention / Behandlung
Detaillierte Beschreibung
Nurses working in the emergency department and critical care units spend a great deal of their time reading or recording ECGs. Practice guidelines require nurses working in units where cardiac monitoring is essential to be skillful in electrocardiography and cardiac monitoring. However, evidence suggests that nurses are still far from achieving this goal. In a study conducted in 65 cardiac care units from three different countries, nurses' (n, 3013) mean total score on an online ECG test was below 50%. However, nurses' mean total score significantly improved after receiving an online ECG monitoring education program. In another study published recently, emergency department and critical care nurses' (n, 210) mean total score in an ECG proficiency test was 18.1 out of 34 with only 61.9% of nurses scoring equal to or higher than 50% of the maximum score. Inadequate nurses' performance on ECG interpretation and cardiac monitoring skills can delay or even prevent lifesaving treatment.
One way of improving emergency and critical care nurses' (ECC) ECG interpretation accuracy is through the utilization of the computer interpretation of the ECG (CIE). This tool is incredibly accurate for certain interpretation algorithms to an extent comparable to a cardiologist, which is considered the gold standard for ECG interpretation. The CIE overall accuracy is estimated to be 90 to 93%. CIE combined with an "over-read" by a well-trained interpreter represents the most accurate form currently available for ECG interpretation. Existing evidence supports CIE ability to improve health care professionals' interpretation accuracy. In a recent study, CIE improved nurses' interpretation accuracy by 16.2%, improved cardiology fellows accuracy by 10.9% , resident physicians by 14.4%, and medical students by 19.9%. In the same study, CIE increased interpretation confidence by 0.06 on a scale from 0 to 1 for all study participants.
In addition to accuracy and improving clinicians' interpretation, especially for less experienced readers, CIE has several other advantages. CIE is especially useful when access to an interpretation expert is not possible; it minimizes expenses; does not fatigue; does not become distracted by outside pressure; objective; not affected by intra or inter-observer variability; decreases interpretation time, on average, by 52 seconds and by 24-28% for the experience reader; makes interpretation easier because it requires no deep knowledge; can take into account age, gender, race, and medication therapy; capable of doing automated serial ECG comparisons; capable of applying multiple and complex criteria, for example in diagnosing left ventricular hypertrophy, that would be difficult or impossible to apply otherwise; leads to faster diagnoses and earlier treatment; can unify diagnostic statements terminology through the following of the terminology adopted by practice guidelines. Such unification of terminology in electrocardiography would facilitate better patient care and unify teaching curriculum all over the world. CIE also continues to improve over time especially with AI evolving technology.
CIE has also several limitations. CIE is generally inaccurate in diagnosing arrhythmia, conduction disturbances, and pace maker rhythms. It is also inaccurate in diagnosing ischemia and myocardial infarction. It is inaccurate in measuring the QT interval, diagnosing long QT interval, and measuring QRS duration. It is inaccurate in diagnosing atrial fibrillation. It misdiagnoses atrial fibrillation and atrial flutter. It does not identify left and right arm lead reversal. The wide variability among different interpretation software with regard to accuracy and employed measurement criteria is another major limitation. However, even with these limitations, the CIE is still considered overall to be accurate.
Nevertheless, despite its great usefulness and potential to advance nursing practice and patient's care, unfortunately nurses are not taught or trained to use this technology. Formal undergraduate, graduate, and clinical education and textbooks do not talk about CIE. Even in research studies evaluating nurses' knowledge and proficiency in electrocardiography, researchers do not include testing items concerning CIE. As far as the investigators know, there is no previous study that has ever specifically evaluated nurses' knowledge in CIE.
The investigators aim from this project which we call "Computer Interpretation of the ECG Raising Awareness CIERA" to raise awareness among nurse practitioners, educators, and managers about the utilization of this technology. Specifically, the investigators aim to introduce three educational interventions (face-to-face, online, and flyer) and assess their effectiveness in improving ECC nurses' proficiency in computer interpretation of the ECG.
The investigators followed the "CONSORT 2010 statement: extension to randomized crossover trials" guidelines in reporting the findings of this trial.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Amman, Jordanien, 11942
- The University of Jordan
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Kind
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
- Every nurse working in the emergency department and critical care units of the participating hospitals
Exclusion Criteria:
- None
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Sonstiges
- Zuteilung: Zufällig
- Interventionsmodell: Crossover-Aufgabe
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: no intervention then a flyer
the flyer was a small, palm-sized, crafted from fine-quality material, thoughtfully designed to be colorful, visually inviting, and easy going, featuring carefully selected introductory images, ample whitespace, and minimal text to ensure clarity, quick engagement, and polished first impression.
|
the flyer was a small, palm-sized, crafted from fine-quality material, thoughtfully designed to be colorful, visually inviting, and easy going, featuring carefully selected introductory images, ample whitespace, and minimal text to ensure clarity, quick engagement, and polished first impression.
|
|
Experimental: Face-to-face then online lectures
the face-to-face content included audiovisual aids, case scenarios, and immediate feedback discussions.
The online content included artificial intelligence enhanced audiovisual aids (videos and images), integrated interactive feedback mechanisms (e.g., requiring the participant to scan a QR code and respond to real-time MCQ questions).
The face-to-face lecture time was totally 45 minutes.
The online total lecture time was 25 minutes.
|
the face-to-face content included audiovisual aids, case scenarios, and immediate feedback discussions.
The face-to-face lecture time was totally 45 minutes
The online content included artificial intelligence enhanced audiovisual aids (videos and images), integrated interactive feedback mechanisms (e.g., requiring the participant to scan a QR code and respond to real-time MCQ questions).
The online total lecture time was 25 minutes.
|
|
Experimental: Online then face-to-face lectures
the face-to-face content included audiovisual aids, case scenarios, and immediate feedback discussions.
The online content included artificial intelligence enhanced audiovisual aids (videos and images), integrated interactive feedback mechanisms (e.g., requiring the participant to scan a QR code and respond to real-time MCQ questions).
The face-to-face lecture time was totally 45 minutes.
The online total lecture time was 25 minutes.
|
the face-to-face content included audiovisual aids, case scenarios, and immediate feedback discussions.
The face-to-face lecture time was totally 45 minutes
The online content included artificial intelligence enhanced audiovisual aids (videos and images), integrated interactive feedback mechanisms (e.g., requiring the participant to scan a QR code and respond to real-time MCQ questions).
The online total lecture time was 25 minutes.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Emergency and Critical Care Nurses Proficiency in Computer Interpretation of the ECG
Zeitfenster: From enrollment to the end of treatment at 5 months
|
Emergency and Critical Care Nurses scores on the "Computer Interpretation of the ECG" test score.
The test is scored out of 28 (range 0 to 28), with higher scores indicating greater proficiency.
The test scale name is "Computer Interpretation of the ECG" test scale
|
From enrollment to the end of treatment at 5 months
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: Amer M Hasanien, PhD, The University of Jordan
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 2289\2024\19 (Andere Zuschuss-/Finanzierungsnummer: The University of Jordan, Deanship of Scientific Research)
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
IPD-Sharing-Zeitrahmen
IPD-Sharing-Zugriffskriterien
Art der unterstützenden IPD-Freigabeinformationen
- STUDIENPROTOKOLL
- SAFT
- ICF
- ANALYTIC_CODE
- CSR
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Flyer
-
University of HawaiiPennington Biomedical Research Center; United States Department of Agriculture...RekrutierungDiät, gesundVereinigte Staaten
-
Cornell UniversityPATH; Institut Pasteur de Madagascar; Université d'AntananarivoNoch keine RekrutierungEisenaufnahme | Darmmikroben | EntzündungMadagaskar