KONECT RESILIA Aortic Valved Conduit (AVC) Real-world Study Assessing Safety and Performance (KONECTION)

16. Juli 2026 aktualisiert von: Edwards Lifesciences
KONECTION is a prospective, observational, single-arm, multicenter study designed to collect real-world clinical outcomes in up to 250 participants who will receive the KONECT RESILIA aortic valved conduit, Model 11060A.

Studienübersicht

Status

Rekrutierung

Intervention / Behandlung

Detaillierte Beschreibung

Subjects in the KONECTION study will be enrolled at up to 20 sites in Europe and Canada. The population will be participants requiring replacement of their diseased native or prosthetic aortic valve, and the associated repair or replacement of a damaged or diseased ascending aorta.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

250

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

    • Bavaria
      • München, Bavaria, Deutschland, 80636
        • Rekrutierung
        • TUM Klinikum Deutsches Herzzentrum
        • Hauptermittler:
          • Markus Krane, Prof. Dr. med.

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Probenahmeverfahren

Wahrscheinlichkeitsstichprobe

Studienpopulation

The target population includes adult candidates who require replacement of their native or prosthetic aortic valve, and the associated repair or replacement of a damaged or diseased ascending aorta.

Beschreibung

Inclusion Criteria:

  1. 18 years or older at the time of informed consent
  2. Have a diseased native or prosthetic aortic valve and a damaged or diseased ascending aorta that requires aortic valved conduit replacement surgery with the KONECT RESILIA AVC
  3. Provide written informed consent
  4. Willing to follow protocol requirements

Exclusion Criteria:

  1. Active endocarditis or endocarditis within 3 months prior to the study index procedure
  2. Emergency procedure
  3. Stage 4 renal disease (estimated glomerular filtration rate [eGFR] <30 excluded) or requiring dialysis
  4. Less than 2-year life expectancy due to non-cardiovascular life-threatening disease in the opinion of the study investigator
  5. High predicted risk of mortality prior to the procedure: Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) ≥8%

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Intervention / Behandlung
Edwards KONECT RESILIA AVC
Subjects who were treated with the Edwards KONECT RESILIA AVC
Surgical replacement of the aortic valve and ascending aorta with the Edwards KONECT RESILIA AVC

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Percentage of participant's freedom from death and/or device related reintervention
Zeitfenster: ≤ 30 days
Participants' freedom from valve-related death or valve- and/or graft-related reintervention. Time to events were estimated by Kaplan-Meier method.
≤ 30 days

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Participant's linearized rate of thromboembolism
Zeitfenster: Events occurring ≥ 31 days and up through 5 years post-implant
A linearized rate percentage is calculated by the following equation: [(Total number of late adverse events in each category/total number of late patient years) x 100]. Late adverse events are events that occur ≥ 31 days post-implant through each subject's last follow-up visit or contact. Late patient years are calculated by totaling the amount of time the valve is implanted in the patient while participating in the trial and the count begins at ≥ 31 days post-implant through all subject's last follow-up visit or contact.
Events occurring ≥ 31 days and up through 5 years post-implant
Participant's linearized rate of valve thrombosis
Zeitfenster: Events occurring ≥ 31 days and up through 5 years post-implant
A linearized rate percentage is calculated by the following equation: [(Total number of late adverse events in each category/total number of late patient years) x 100]. Late adverse events are events that occur ≥ 31 days post-implant through each subject's last follow-up visit or contact. Late patient years are calculated by totaling the amount of time the valve is implanted in the patient while participating in the trial and the count begins at ≥ 31 days post-implant through all subject's last follow-up visit or contact.
Events occurring ≥ 31 days and up through 5 years post-implant
Participant's linearized rate of major paravalvular leak
Zeitfenster: Events occurring ≥ 31 days and up through 5 years post-implant
A linearized rate percentage is calculated by the following equation: [(Total number of late adverse events in each category/total number of late patient years) x 100]. Late adverse events are events that occur ≥ 31 days post-implant through each subject's last follow-up visit or contact. Late patient years are calculated by totaling the amount of time the valve is implanted in the patient while participating in the trial and the count begins at ≥ 31 days post-implant through all subject's last follow-up visit or contact.
Events occurring ≥ 31 days and up through 5 years post-implant
Participant's linearized rate of endocarditis
Zeitfenster: Events occurring ≥ 31 days and up through 5 years post-implant
A linearized rate percentage is calculated by the following equation: [(Total number of late adverse events in each category/total number of late patient years) x 100]. Late adverse events are events that occur ≥ 31 days post-implant through each subject's last follow-up visit or contact. Late patient years are calculated by totaling the amount of time the valve is implanted in the patient while participating in the trial and the count begins at ≥ 31 days post-implant through all subject's last follow-up visit or contact.
Events occurring ≥ 31 days and up through 5 years post-implant
Participant's linearized rate of major hemorrhage
Zeitfenster: Events occurring ≥ 31 days and up through 5 years post-implant
A linearized rate percentage is calculated by the following equation: [(Total number of late adverse events in each category/total number of late patient years) x 100]. Late adverse events are events that occur ≥ 31 days post-implant through each subject's last follow-up visit or contact. Late patient years are calculated by totaling the amount of time the valve is implanted in the patient while participating in the trial and the count begins at ≥ 31 days post-implant through all subject's last follow-up visit or contact.
Events occurring ≥ 31 days and up through 5 years post-implant
Percentage of participant's with freedom from death and/or device related reintervention
Zeitfenster: 1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-, 9-, and 10- Years follow-up
Participants' freedom from valve-related death or valve- and/or graft-related reintervention. Time to events were estimated by Kaplan-Meier method.
1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-, 9-, and 10- Years follow-up
Participant's functional improvement over time from baseline for New York Heart Association (NYHA) Class
Zeitfenster: Baseline, 1 month, 1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-, 9-, and 10- Years follow-up

The New York Heart Association functional classification system relates symptoms to everyday activities and the patient's quality of life.

Class I. Patients with cardiac disease but without resulting limitation of physical activity.

Class II. Patients with cardiac disease resulting in slight limitation of physical activity. They are comfortable at rest.

Class III. Patients with cardiac disease resulting in marked limitation of physical activity. They are comfortable at rest.

Class IV. Patients with cardiac disease resulting in inability to carry on any physical activity without discomfort.

Symptoms of heart failure or anginal syndrome may be present even at rest.

Baseline, 1 month, 1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-, 9-, and 10- Years follow-up
Participant's average mean gradient measurement over time
Zeitfenster: 1 month, 1-, 3-, and 5- Years follow-up
Mean gradient is the average flow of blood through the aortic valve measured in millimeters of mercury. Gradients are evaluated by echocardiography over time. In general, a higher value is considered worse, and a lower value is considered better but the value is dependent on the size and type of valve.
1 month, 1-, 3-, and 5- Years follow-up
Participant's average peak gradient measurement over time
Zeitfenster: 1 month, 1-, 3-, and 5- Years follow-up
Peak gradient is the maximum value measured of flow of blood through the aortic valve as measured in millimeters of mercury. Gradients are evaluated by echocardiography over time. In general, a higher valve is considered worse, and a lower value is considered better, but the value is dependent on the size and type of valve.
1 month, 1-, 3-, and 5- Years follow-up
Participant's average Effective Orifice Area (EOA) measurement over time
Zeitfenster: 1 month, 1-, 3-, and 5- Years follow-up
Effective orifice area represents the cross-sectional area of the blood flow downstream of the aortic valve. Effective orifice area is evaluated by echocardiography over time. In general, a higher value is considered better, and a lower value is considered worse, but the value is dependent on the size and type of valve.
1 month, 1-, 3-, and 5- Years follow-up
Participant's average Effective Orifice Area Index (EOAI) measurement over time
Zeitfenster: 1 month, 1-, 3-, and 5- Years follow-up
Effective orifice area index represents the minimal cross-sectional area of the blood flow downstream of the aortic valve divided by the person's body surface area. Effective orifice area index is evaluated by echocardiography over time. In general, a higher value is considered better, and a lower value is considered worse, but the value is dependent on the size of the patient and the size and type of valve.
1 month, 1-, 3-, and 5- Years follow-up

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Markus Krane, Prof. Dr. med., TUM Universitätsklinikum Deutsches Herzzentrum

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

25. Juni 2026

Primärer Abschluss (Geschätzt)

31. Dezember 2028

Studienabschluss (Geschätzt)

30. Juni 2039

Studienanmeldedaten

Zuerst eingereicht

26. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

26. Mai 2026

Zuerst gepostet (Tatsächlich)

2. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

17. Juli 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

16. Juli 2026

Zuletzt verifiziert

1. Juli 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Schlüsselwörter

Andere Studien-ID-Nummern

  • 2025-02

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Beschreibung des IPD-Plans

Individual participant data will not be available to other researchers.

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Ja

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren