Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Effect of Mechanical Power-based Lung-protective Ventilation During One-lung Ventilation

25. August 2026 aktualisiert von: Heejoon Jeong, Samsung Medical Center

Incidence of Postoperative Pulmonary Complications Between Mechanical Power-based Versus Conventional Lung Protective Ventilation During One-lung Ventilation: a Randomized Controlled Trial

The goal of this clinical trial is to determine whether a mechanical power-based lung-protective ventilation strategy during one-lung ventilation reduces the incidence of postoperative pulmonary complications in adult patients undergoing lung resection surgery.

Mechanical power during pressure-regulated volume control mode is calculated using the formula below.

Mechanical power (J/min) = 0.098 x respiratory rate x tidal volume x (inspiratory airway pressure above positive end-expiratory pressure + positive end-expiratory pressure)

The main questions it aims to answer are:

  • Does a mechanical power-based lung-protective ventilation strategy significantly lower the incidence of major postoperative pulmonary complications compared to conventional ventilation?
  • How does this strategy impact intraoperative hemodynamic and vital profiles (e.g., blood pressure, cardiac output, vasopressor requirements, and blood oxygen saturation) during one-lung ventilation?

Participants will:

  • Be randomized to receive either a mechanical power-based lung-protective ventilation strategy or a conventional lung-protective ventilation strategy exclusively during one-lung ventilation.
  • Be closely monitored for the occurrence of major postoperative pulmonary complications (atelectasis, pneumonia, acute respiratory distress syndrome, and pulmonary aspiration) and adverse events for 1 month postoperatively.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Geschätzt)

164

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

  • Name: Heejoon Jeong Anesthesiologist, Professor, MD
  • Telefonnummer: +82-2-3410-0841
  • E-Mail: heejoonjeong@skku.edu

Studienorte

      • Seoul, Südkorea, 06351
        • Samsung Medical Center
        • Hauptermittler:
          • Heejoon Jeong, MD
        • Kontakt:
          • Heejoon Jeong Anesthesiologist, Professor, MD
          • Telefonnummer: +82-2-3410-0841
          • E-Mail: heejoonjeong@skku.edu

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria

  • American Society of Anesthesiologists (ASA) physical status I-III
  • Elective thoracic surgery requiring lung lobectomy under one-lung ventilation
  • Age 18 years or older
  • Written informed consent obtained from the patient

Exclusion Criteria

  • Prior history of thoracic surgery
  • Emergency surgery
  • Pregnancy or lactation
  • Known contraindication to one-lung ventilation
  • Inability to provide informed consent or cooperate with the study protocol

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Mechanical power-based lung protective ventilation group
Patients in this group will receive the mechanical power-based lung-protective ventilation strategy during one-lung ventilation.

Initial Settings

1) Tidal Volume: 4-6 mL/kg of predicted body weight 2) Positive End-Expiratory Pressure: Set to the value that minimizes driving pressure 3) Respiratory Rate: Adjusted to maintain an end-tidal carbon dioxide of 35-45 mmHg Protocol

  1. If mechanical power exceeds 7 J/min, decrease the respiratory rate by 1 and reduce the tidal volume by 5%, then maintain these settings for 1 minute.
  2. If mechanical power remains above 7 J/min after 1 minute, further decrease the respiratory rate by 1 and reduce the tidal volume by an additional 5%, then maintain for 1 minute.
  3. If end-tidal carbon dioxide exceeds 50 mmHg, perform arterial blood gas analysis to check arterial pH.
  4. If arterial pH drops below 7.2, the intervention will be discontinued, and the patient will be withdrawn from the study and treated with conventional treatment.
Aktiver Komparator: Conventional ventilation group
Patients in this group will receive the conventional lung-protective ventilation strategy during one-lung ventilation.

Ventilator Settings

  • Tidal Volume: 4-6 mL/kg of predicted body weight
  • Positive End-Expiratory Pressure: 5 cmH2O
  • Respiratory Rate: Adjusted to maintain an end-tidal carbon dioxide of 35-45 mmHg

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Postoperative pulmonary complication
Zeitfenster: From enrollment to 7 days postoperatively

Composite of respiratory diagnoses that share common pathophysiological mechanisms, including pulmonary collapse and airway contamination:

  1. atelectasis detected on computed tomography or chest radiograph,
  2. pneumonia using United States Centers for Disease Control criteria,
  3. acute respiratory distress syndrome using the Berlin consensus definition, and
  4. pulmonary aspiration (clear clinical history AND radiological evidence).
From enrollment to 7 days postoperatively

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Clavien-Dindo classification
Zeitfenster: From enrollment to 30 days postoperatively

The Clavien-Dindo classification is a standardized grading system for postoperative complications based on the therapeutic treatment required to manage the complication.

The Clavien-Dindo classification grades surgical complications according to the invasiveness and complexity of the therapy needed to treat them, ranging from any deviation from the normal postoperative course to death.

Grading Scale Overview Grade I: Any deviation from the normal postoperative course without the need for pharmacological treatment.

Grade II: Requiring pharmacological treatment with drugs other than those allowed for Grade I complications Grade III: Requiring surgical, endoscopic, or radiological intervention. Grade IV: Life-threatening complication. Grade V: Death of a patient

From enrollment to 30 days postoperatively

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

30. August 2026

Primärer Abschluss (Geschätzt)

30. August 2027

Studienabschluss (Geschätzt)

30. September 2027

Studienanmeldedaten

Zuerst eingereicht

14. August 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

14. August 2026

Zuerst gepostet (Tatsächlich)

19. August 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

27. August 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

25. August 2026

Zuletzt verifiziert

1. August 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren