Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Guangke Lenses in Congenital Cataract

18. August 2026 aktualisiert von: Jin Yang, Eye & ENT Hospital of Fudan University

Investigation of Guangke Lenses' Efficacy in Delaying Myopia Onset/Progression in Postoperative Congenital Cataract Children

This study aims to investigate whether individually customized bifocal + defocus spectacles can slow myopic shift in children after congenital cataract surgery.

Studienübersicht

Detaillierte Beschreibung

Children with congenital cataract who have undergone surgery will be fitted with individually customized bifocal + defocus spectacles. Refraction and axial length will be monitored at regular intervals to assess the effect of the intervention on myopic progression.

Studientyp

Interventionell

Einschreibung (Geschätzt)

50

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

    • Shanghai Municipality
      • Shanghai, Shanghai Municipality, China, 200031
        • Rekrutierung
        • Eye & ENT Hospital of Fudan University
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Kind

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

Aged 4 to 12 years (inclusive) at the time of enrollment. Diagnosed with bilateral congenital cataracts. Has undergone bilateral cataract extraction with intraocular lens (IOL) implantation.

Time since cataract surgery is between 1 to 6 months (inclusive) at the time of enrollment.

Able to undergo regular ophthalmic examinations (including refraction, axial length measurement, and intraocular pressure assessment).

Parent(s) or legal guardian(s) are willing and able to provide written informed consent.

Exclusion Criteria:

Presence of any systemic disease (e.g., metabolic disorders, autoimmune diseases, genetic syndromes, etc.).

Presence of any ocular disease other than congenital cataracts (e.g., glaucoma, uveitis, retinal disorders, corneal diseases, strabismus, amblyopia, etc.).

Previous or current use of myopia control treatments, including but not limited to atropine eye drops, orthokeratology (Ortho-K) lenses, or other myopia control spectacle lenses.

History of ocular trauma or intraocular surgery other than cataract extraction and IOL implantation.

Known allergy or hypersensitivity to any materials or components used in the study lenses.

Inability to comply with the study protocol or complete scheduled follow-up visits.

Participation in another interventional clinical trial within the past 30 days.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Nicht randomisiert
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: Active Comparator: Conventional Bifocal Lenses
Participants in this arm will wear conventional bifocal spectacles (without defocus design).
Standard conventional bifocal spectacles without peripheral defocus design.
Experimental: Experimental: Individually Customized Bifocal + Defocus Lenses
Participants in this arm will wear individually customized bifocal spectacles with peripheral defocus design.
Individually customized bifocal spectacles with peripheral defocus design for myopia control.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Change in Axial Length (AL)
Zeitfenster: Baseline to 12 months
Change in axial length (in millimeters) from baseline measured by optical biometry.
Baseline to 12 months
Change in Spherical Equivalent Refraction (SER)
Zeitfenster: Baseline to 12 months
Change in spherical equivalent refraction (in diopters) measured by cycloplegic autorefraction from baseline.
Baseline to 12 months

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Change in Corneal Curvature
Zeitfenster: Baseline to 12 months
Change in corneal curvature (in millimeters) measured by corneal topography.
Baseline to 12 months
Change in Intraocular Pressure (IOP)
Zeitfenster: Baseline to 12 months
Change in IOP (in mmHg) measured by non-contact tonometry.
Baseline to 12 months
Incidence of Adverse Events
Zeitfenster: Baseline to 12 months
Number of participants with ocular or systemic adverse events related to the study lenses.
Baseline to 12 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

6. August 2025

Primärer Abschluss (Geschätzt)

6. August 2028

Studienabschluss (Geschätzt)

6. August 2030

Studienanmeldedaten

Zuerst eingereicht

18. August 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

18. August 2026

Zuerst gepostet (Tatsächlich)

21. August 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

21. August 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

18. August 2026

Zuletzt verifiziert

1. August 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • Guangke lenses_2025

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren