Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Comparison of the Ultra-low-dose Veo Algorithm With the Gold Standard Filtered Back Projection for Detecting Pulmonary Asbestos-related Conditions

5 de agosto de 2026 actualizado por: University Hospital, Clermont-Ferrand

Asbestos fibers were intensively used throughout the 20th century and remain prevalent in developing countries. However, asbestos exposure induces a variety of benign and malignant pleural and lung diseases. The most common asbestos-induced neoplasm is lung cancer. Moreover, thin-section computed tomography (CT) is more sensitive than a chest x-ray for detecting early asbestos-related conditions. Increased exposure to radiation underpins the consequences of cancer induction. However, reducing CT doses increases image noise from the filtered back projection (FBP) reconstruction. Strategies to reduce radiation exposure include the use of iterative reconstruction algorithms. A new algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA) decreases the image noise up to 70% compared with the gold standard FBP model. Moreover, Veo improves spatial resolution with excellent detection of low and high contrast objects from a CT Dose Index (CTDIvol) equal to 0.3 mGy.

The objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality.

Descripción general del estudio

Descripción detallada

Asbestos-exposed workers will be recruited following referral to our radiology department for the evaluation of asbestos-related disease. CT examinations will be performed with a 64-slice CT system (Discovery CT 750HD; GE Healthcare, Milwaukee, WI) and will consist of two successive acquisitions. Each examination, the normal-dose (FBP acquisition) and ultra-low-dose (Veo acquisition) spiral CT, will be performed in supine position, on the entire thorax, at full inspiration and without contrast agent injection.

In order to perform the two acquisitions without increasing radiation, standard acquisition will be performed with the same kV with mA equal to patient's body weight minus 10. To conserve image quality, 60 mA will be the inferior limit. The other CT parameters will be rotation time 0.5 s and pitch 1.375. Image data will be reconstructed with FBP algorithm.

The Veo acquisition will be performed with constant CT parameters including: a tube voltage of 100 kV, a tube current of 20 mA, pitch of 0.984 and rotation time 0.4 s. Image data will be reconstructed with the Veo algorithm.

Each CT acquisition will be viewed independently by two experienced radiologists (2 to 7 years of experience). The low-dose images with Veo reconstruction will be interpreted before the standard CT and on separate weeks to minimize recall bias. Then, the more experienced radiologist will evaluate the detection and characterization of pleuroparenchymal abnormalities by a second and simultaneous reading of the Veo and FBP acquisitions. Because FBP images are benchmark practice, when a lesion will be found only on Veo images, it will be regarded as a false positive.

The following asbestos-related pleural and parenchymal abnormalities will be recorded as present or absent. Pleural abnormalities considered will be: pleural plaques, diffuse pleural thickening and pleural effusion.

CT features of asbestosis will include subpleural dots and branching opacities, curvilinear subpleural lines, areas of ground glass opacities, septal lines, reticulations and honeycombing.

Presence of nodules will also be recorded. We will note for each abnormality: localization (side, table position) and nature (non-solid, part-solid, solid or calcified).

Tipo de estudio

Intervencionista

Inscripción (Actual)

90

Fase

  • Fase 4

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Clermont-Ferrand, Francia, 63003
        • CHU Clermont-Ferrand

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 90 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • asbestos-exposed workers
  • ability to give a written informed consent

Exclusion Criteria:

  • - previous history of cancer
  • previous history of thoracic surgery
  • other interstitial pathology known

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: VeoTM
A new algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA) decreases the image noise up to 70% compared with the gold standard FBP model. Moreover, Veo improves spatial resolution with excellent detection of low and high contrast objects from a CT Dose Index (CTDIvol) equal to 0.3 mGy
The objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality.
Otro: gold standard FBP model
The objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality
The objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Pleural and parenchymal abnormalities
Periodo de tiempo: at day 1
The kappa coefficient will be used to measure agreement for categorical parameters and Pearson's correlation coefficient and Lin concordance correlation coefficient for quantitative data.
at day 1

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Radiation dose
Periodo de tiempo: at day 1
The dose length product (DLP) will be recorded.
at day 1
Quality images assessment
Periodo de tiempo: at day 1

Respiratory artifacts will be graded on a three-point scale (1 = negligible, 2 = moderate, 3 = salient).

Images noise will be studied in the axial and coronal planes. A similar scale will be used for subjective image quality in the mediastinum and parenchyma windows.

Objective image noise (Standard Deviation) and average CT numbers (in Hounsfield's units) will be measured with circular regions of interest (ROI) on different anatomical levels, 10 mm in diameter.

The signal to noise ratio (SNR) will also be calculated using the equation SNR = CT numbers / noise.

at day 1

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Frederic DUTHEIL, University Hospital, Clermont-Ferrand

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de septiembre de 2012

Finalización primaria (Actual)

1 de abril de 2013

Finalización del estudio (Actual)

1 de mayo de 2013

Fechas de registro del estudio

Enviado por primera vez

2 de septiembre de 2013

Primero enviado que cumplió con los criterios de control de calidad

4 de octubre de 2013

Publicado por primera vez (Estimado)

7 de octubre de 2013

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

7 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

5 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Términos MeSH relevantes adicionales

Otros números de identificación del estudio

  • CHU-0166
  • 2012-A00618-35

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir