- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT04300972
Comparison of Contrast Agent Administration Protocols
The will compare two different ways of administering contrast media in CT exams of the chest:
- a fixed dose of contrast medium
- a weight- and body-type-adapted dose of contrast medium
The goal is to see if one protocol is superior to the other in reliably producing diagnostic CT images.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality, clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges deals with intravenous contrast medium (CM) administration. Although multidetector CT allows more efficient and flexible use of contrast medium than single-detector CT, to fully reap the benefits of multidetector CT, certain technical challenges involving maximum contrast enhancement and optimal contrast material delivery must be met (1). While CT technology has evolved, the practice of CT intravenous CM administration has been continually debated and updated. The users of new CT technology, accompanied with its newly added technical complexity, discover they fall short of achieving a desired image quality with the traditional standard administration of CM. This entails a change in practice. In the department of Radiology at St Olav University Hospital (SOH), a new protocol for CM administration is now developed and is ready for implementation. This protocol is based on a body weight adapted CM administration, while the current protocol has a fixed CM injection. In this study, this newly CM administration protocol for thoracic CT will be compared to the fixed CM injection protocol. To our knowledge, very few studies (2) have been published on the use of body weight adapted injection protocols for Thoracic CT. Most of the studies report the impact of body weight adapted CM injection protocols for the coronary arteries of CT angiography (3- 5). Therefore, the aim of this study is to determine whether individually tailored protocol(s) for the injection of CM results in higher and more homogeneous vascular attenuation at thoracic CT compared with conventional injection protocols using fixed injection parameters. We know that to achieve optimal contrast enhancement in thoracic CT involves essential factors such as CT tube voltage and CT attenuation, patient factors, CM factors and CT scanning factors (1) and thus all these factors will be addressed and discussed in this investigation.
Specific aims of the study:
- To assess and compare the CT attenuation achieved with both protocols
- Compare the required amount of CM using weight adapted CM protocol and fixed CM injection protocol
- Compare the quality of the images using weight adapted CM protocol and fixed CM injection protocol
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
All patients referred for a thoracic CT (only) at St. Olavs Hospital will be screened for eligibility Inclusion criteria are
-referral indicates the need for contrast administration (as decided by a radiologist)
Exclusion criteria are:
- impaired renal function (glomerular filtration rate <60 ml/min)
- congenital heart disease (as indicated by referral)
- congestive heart failure (as indicated by referral)
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Otro: fixed dose
|
a fixed amount of contrast media is used, independently of weight and body type
|
|
Experimental: weight and body type adapted dose
|
contrast media dose is adapted to weight and body type
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
CT density of large vessel, measured in Hounsfield units (HU) in the imaging software (PACS)
Periodo de tiempo: immediately after imaging
|
immediately after imaging
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- CMProtokoll
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .