Comparison of Contrast Agent Administration Protocols
The will compare two different ways of administering contrast media in CT exams of the chest:
- a fixed dose of contrast medium
- a weight- and body-type-adapted dose of contrast medium
The goal is to see if one protocol is superior to the other in reliably producing diagnostic CT images.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality, clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges deals with intravenous contrast medium (CM) administration. Although multidetector CT allows more efficient and flexible use of contrast medium than single-detector CT, to fully reap the benefits of multidetector CT, certain technical challenges involving maximum contrast enhancement and optimal contrast material delivery must be met (1). While CT technology has evolved, the practice of CT intravenous CM administration has been continually debated and updated. The users of new CT technology, accompanied with its newly added technical complexity, discover they fall short of achieving a desired image quality with the traditional standard administration of CM. This entails a change in practice. In the department of Radiology at St Olav University Hospital (SOH), a new protocol for CM administration is now developed and is ready for implementation. This protocol is based on a body weight adapted CM administration, while the current protocol has a fixed CM injection. In this study, this newly CM administration protocol for thoracic CT will be compared to the fixed CM injection protocol. To our knowledge, very few studies (2) have been published on the use of body weight adapted injection protocols for Thoracic CT. Most of the studies report the impact of body weight adapted CM injection protocols for the coronary arteries of CT angiography (3- 5). Therefore, the aim of this study is to determine whether individually tailored protocol(s) for the injection of CM results in higher and more homogeneous vascular attenuation at thoracic CT compared with conventional injection protocols using fixed injection parameters. We know that to achieve optimal contrast enhancement in thoracic CT involves essential factors such as CT tube voltage and CT attenuation, patient factors, CM factors and CT scanning factors (1) and thus all these factors will be addressed and discussed in this investigation.
Specific aims of the study:
- To assess and compare the CT attenuation achieved with both protocols
- Compare the required amount of CM using weight adapted CM protocol and fixed CM injection protocol
- Compare the quality of the images using weight adapted CM protocol and fixed CM injection protocol
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
All patients referred for a thoracic CT (only) at St. Olavs Hospital will be screened for eligibility Inclusion criteria are
-referral indicates the need for contrast administration (as decided by a radiologist)
Exclusion criteria are:
- impaired renal function (glomerular filtration rate <60 ml/min)
- congenital heart disease (as indicated by referral)
- congestive heart failure (as indicated by referral)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Altro: fixed dose
|
a fixed amount of contrast media is used, independently of weight and body type
|
|
Sperimentale: weight and body type adapted dose
|
contrast media dose is adapted to weight and body type
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
CT density of large vessel, measured in Hounsfield units (HU) in the imaging software (PACS)
Lasso di tempo: immediately after imaging
|
immediately after imaging
|
Collaboratori e investigatori
Sponsor
Collaboratori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- CMProtokoll
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .