Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Artificial Intelligence Versus Anesthesiologist Visual Assessment of Ejection Fraction by Transesophageal Echocardiography During Cardiac Surgery

20 de septiembre de 2026 actualizado por: Ain Shams University

Reliability of Artificial Intelligent General Application in Assessing Ejection Fraction in Comparison to Anesthesiologist Eye Ball by Trans Oesophageal Echo During Cardiac Surgery

This prospective observational study evaluated the reliability of a general-purpose artificial intelligence application in estimating left ventricular ejection fraction from intraoperative transesophageal echocardiography images during cardiac surgery. The artificial intelligence estimates were compared with visual assessment by two independent blinded professor anesthesiologists and with preoperative transthoracic echocardiography findings. Ejection fraction measured using M-mode and the time required for each assessment were also evaluated. The study included 93 adults undergoing elective coronary artery bypass grafting or valve surgery. The artificial intelligence assessments were performed using pseudonymized images and were not used to guide clinical decisions or patient management.

Descripción general del estudio

Descripción detallada

This was a prospective, single-cohort observational study conducted at the Cardiothoracic Surgery Academy, Ain Shams University. Adults aged 21 years or older undergoing elective coronary artery bypass grafting or valve repair or replacement surgery were enrolled consecutively after providing written informed consent.

After induction of anesthesia and hemodynamic stabilization, transesophageal echocardiography images were obtained using a transgastric short-axis view at the mid-papillary level and an angle of 0 degrees. End-diastolic and end-systolic frames and an M-mode recording were collected for assessment of left ventricular ejection fraction.

Pseudonymized echocardiographic images were assessed using a general-purpose artificial intelligence application. The same images were independently assessed by two blinded professor anesthesiologists who had no access to the artificial intelligence output or the other assessments. Visual estimation of ejection fraction, M-mode-derived ejection fraction, and interpretation time were recorded. These findings were also compared with the preoperative transthoracic echocardiography assessment.

The artificial intelligence output was used exclusively for research and was not used to make or modify any clinical decision. A total of 93 eligible participants were included in the final analysis.

Tipo de estudio

De observación

Inscripción (Actual)

93

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Cairo Governorate
      • Cairo, Cairo Governorate, Egipto
        • Cardiothoracic Surgery Academy, Ain Shams University Hospitals

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

21 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

Adult patients aged 21 years or older who were scheduled for elective coronary artery bypass grafting, valve repair, or valve replacement surgery at the Cardiothoracic Surgery Academy, Ain Shams University and had an available preoperative transthoracic echocardiographic assessment.

Descripción

Inclusion Criteria:

  • Age 21 years or older.
  • Scheduled for elective cardiac surgery involving coronary artery bypass grafting, valve repair, or valve replacement.
  • Availability of a preoperative transthoracic echocardiographic assessment.
  • Either sex.
  • American Society of Anesthesiologists physical status III or IV.

Exclusion Criteria:

  • Coagulopathy, defined as an international normalized ratio greater than 2 or a platelet count below 50,000/mm3.
  • Previous cardiac surgery (redo procedure).
  • Esophageal or upper gastrointestinal pathology preventing safe transesophageal echocardiography probe placement, including esophageal stricture, tumor, or large varices.
  • Poor-quality transesophageal echocardiography images despite standard optimization, preventing reliable interpretation.
  • Severe arrhythmia or hemodynamic instability before surgery, during induction, or during surgery that could compromise the accuracy of the transesophageal echocardiography assessment.
  • Refusal to participate or a condition limiting valid consent or participation, including cognitive impairment or a language barrier.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: COHORT
  • Perspectivas temporales: PROSPECTIVE

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Elective Cardiac Surgery Patients

A single cohort of 93 adult patients undergoing elective coronary artery bypass grafting or valve repair or replacement surgery. Intraoperative transesophageal echocardiography images were evaluated for left ventricular ejection fraction using artificial intelligence, anesthesiologist visual assessment, and M-mode echocardiography.

Pseudonymized end-diastolic and end-systolic frames and an M-mode recording obtained from the transgastric short-axis mid-papillary view at 0 degrees were analyzed by a general-purpose artificial intelligence application to estimate left ventricular ejection fraction. The artificial intelligence results were compared with assessments by two independent blinded professor anesthesiologists and with preoperative transthoracic echocardiography. The artificial intelligence output was used only for research and did not guide clinical management.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Difference Between AI and Anesthesiologist Visual Assessment of LVEF
Periodo de tiempo: During cardiac surgery, at the time of the intraoperative TEE assessment

Left ventricular ejection fraction was assessed from the same intraoperative transesophageal echocardiography transgastric short-axis mid-papillary view at 0 degrees by a general-purpose artificial intelligence application and by two independent blinded professor anesthesiologists using visual (eyeball) assessment. The paired assessments were compared to evaluate the difference and agreement between the artificial intelligence and anesthesiologist assessments.

During cardiac surgery, at the time of the intraoperative TEE assessment

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Difference Between AI and Anesthesiologist M-Mode Assessment of LVEF
Periodo de tiempo: During cardiac surgery, at the time of the intraoperative TEE assessment

Left ventricular ejection fraction was assessed using M-mode in the intraoperative transesophageal echocardiography transgastric short-axis mid-papillary view at 0 degrees by a general-purpose artificial intelligence application and by two independent blinded professor anesthesiologists. The paired M-mode ejection fraction assessments were compared to evaluate the difference and agreement between methods.

During cardiac surgery, at the time of the intraoperative TEE assessment
Time Required for AI and Anesthesiologist LVEF Assessment
Periodo de tiempo: During intraoperative TEE image review, from the start of each visual (eyeball) or M-mode LVEF assessment until the corresponding estimate is completed, assessed up to 3 minutes per assessment per participant.

The time required for the general-purpose artificial intelligence application and the anesthesiologist assessors to complete the visual (eyeball) and M-mode left ventricular ejection fraction assessments was recorded separately using a timer and reported in seconds. Assessment times were compared between the artificial intelligence and anesthesiologist methods.

During intraoperative TEE image review, from the start of each visual (eyeball) or M-mode LVEF assessment until the corresponding estimate is completed, assessed up to 3 minutes per assessment per participant.
Difference Between Intraoperative TEE and Preoperative TTE LVEF Assessments
Periodo de tiempo: From the available preoperative TTE assessment to the intraoperative TEE assessment during cardiac surgery

Left ventricular ejection fraction estimates obtained from intraoperative transesophageal echocardiography by the general-purpose artificial intelligence application and the blinded anesthesiologist assessors were compared with the available preoperative transthoracic echocardiography ejection fraction for the same participant. The difference between each intraoperative assessment and the preoperative transthoracic echocardiography value was evaluated.

From the available preoperative TTE assessment to the intraoperative TEE assessment during cardiac surgery

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

28 de marzo de 2026

Finalización primaria (Actual)

22 de agosto de 2026

Finalización del estudio (Actual)

22 de agosto de 2026

Fechas de registro del estudio

Enviado por primera vez

14 de septiembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

20 de septiembre de 2026

Publicado por primera vez (Actual)

25 de septiembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

25 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

20 de septiembre de 2026

Última verificación

1 de septiembre de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

Individual participant data will not be shared because external sharing of participant-level data was not included in the approved study protocol, ethics approval, or informed consent. Only aggregate study results will be reported.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir