Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Artificial Intelligence Versus Anesthesiologist Visual Assessment of Ejection Fraction by Transesophageal Echocardiography During Cardiac Surgery

20 сентября 2026 г. обновлено: Ain Shams University

Reliability of Artificial Intelligent General Application in Assessing Ejection Fraction in Comparison to Anesthesiologist Eye Ball by Trans Oesophageal Echo During Cardiac Surgery

This prospective observational study evaluated the reliability of a general-purpose artificial intelligence application in estimating left ventricular ejection fraction from intraoperative transesophageal echocardiography images during cardiac surgery. The artificial intelligence estimates were compared with visual assessment by two independent blinded professor anesthesiologists and with preoperative transthoracic echocardiography findings. Ejection fraction measured using M-mode and the time required for each assessment were also evaluated. The study included 93 adults undergoing elective coronary artery bypass grafting or valve surgery. The artificial intelligence assessments were performed using pseudonymized images and were not used to guide clinical decisions or patient management.

Обзор исследования

Подробное описание

This was a prospective, single-cohort observational study conducted at the Cardiothoracic Surgery Academy, Ain Shams University. Adults aged 21 years or older undergoing elective coronary artery bypass grafting or valve repair or replacement surgery were enrolled consecutively after providing written informed consent.

After induction of anesthesia and hemodynamic stabilization, transesophageal echocardiography images were obtained using a transgastric short-axis view at the mid-papillary level and an angle of 0 degrees. End-diastolic and end-systolic frames and an M-mode recording were collected for assessment of left ventricular ejection fraction.

Pseudonymized echocardiographic images were assessed using a general-purpose artificial intelligence application. The same images were independently assessed by two blinded professor anesthesiologists who had no access to the artificial intelligence output or the other assessments. Visual estimation of ejection fraction, M-mode-derived ejection fraction, and interpretation time were recorded. These findings were also compared with the preoperative transthoracic echocardiography assessment.

The artificial intelligence output was used exclusively for research and was not used to make or modify any clinical decision. A total of 93 eligible participants were included in the final analysis.

Тип исследования

Наблюдательный

Регистрация (Действительный)

93

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Cairo Governorate
      • Cairo, Cairo Governorate, Египет
        • Cardiothoracic Surgery Academy, Ain Shams University Hospitals

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

21 год и старше (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Метод выборки

Невероятностная выборка

Исследуемая популяция

Adult patients aged 21 years or older who were scheduled for elective coronary artery bypass grafting, valve repair, or valve replacement surgery at the Cardiothoracic Surgery Academy, Ain Shams University and had an available preoperative transthoracic echocardiographic assessment.

Описание

Inclusion Criteria:

  • Age 21 years or older.
  • Scheduled for elective cardiac surgery involving coronary artery bypass grafting, valve repair, or valve replacement.
  • Availability of a preoperative transthoracic echocardiographic assessment.
  • Either sex.
  • American Society of Anesthesiologists physical status III or IV.

Exclusion Criteria:

  • Coagulopathy, defined as an international normalized ratio greater than 2 or a platelet count below 50,000/mm3.
  • Previous cardiac surgery (redo procedure).
  • Esophageal or upper gastrointestinal pathology preventing safe transesophageal echocardiography probe placement, including esophageal stricture, tumor, or large varices.
  • Poor-quality transesophageal echocardiography images despite standard optimization, preventing reliable interpretation.
  • Severe arrhythmia or hemodynamic instability before surgery, during induction, or during surgery that could compromise the accuracy of the transesophageal echocardiography assessment.
  • Refusal to participate or a condition limiting valid consent or participation, including cognitive impairment or a language barrier.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Наблюдательные модели: COHORT
  • Временные перспективы: PROSPECTIVE

Когорты и вмешательства

Группа / когорта
Вмешательство/лечение
Elective Cardiac Surgery Patients

A single cohort of 93 adult patients undergoing elective coronary artery bypass grafting or valve repair or replacement surgery. Intraoperative transesophageal echocardiography images were evaluated for left ventricular ejection fraction using artificial intelligence, anesthesiologist visual assessment, and M-mode echocardiography.

Pseudonymized end-diastolic and end-systolic frames and an M-mode recording obtained from the transgastric short-axis mid-papillary view at 0 degrees were analyzed by a general-purpose artificial intelligence application to estimate left ventricular ejection fraction. The artificial intelligence results were compared with assessments by two independent blinded professor anesthesiologists and with preoperative transthoracic echocardiography. The artificial intelligence output was used only for research and did not guide clinical management.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Difference Between AI and Anesthesiologist Visual Assessment of LVEF
Временное ограничение: During cardiac surgery, at the time of the intraoperative TEE assessment

Left ventricular ejection fraction was assessed from the same intraoperative transesophageal echocardiography transgastric short-axis mid-papillary view at 0 degrees by a general-purpose artificial intelligence application and by two independent blinded professor anesthesiologists using visual (eyeball) assessment. The paired assessments were compared to evaluate the difference and agreement between the artificial intelligence and anesthesiologist assessments.

During cardiac surgery, at the time of the intraoperative TEE assessment

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Difference Between AI and Anesthesiologist M-Mode Assessment of LVEF
Временное ограничение: During cardiac surgery, at the time of the intraoperative TEE assessment

Left ventricular ejection fraction was assessed using M-mode in the intraoperative transesophageal echocardiography transgastric short-axis mid-papillary view at 0 degrees by a general-purpose artificial intelligence application and by two independent blinded professor anesthesiologists. The paired M-mode ejection fraction assessments were compared to evaluate the difference and agreement between methods.

During cardiac surgery, at the time of the intraoperative TEE assessment
Time Required for AI and Anesthesiologist LVEF Assessment
Временное ограничение: During intraoperative TEE image review, from the start of each visual (eyeball) or M-mode LVEF assessment until the corresponding estimate is completed, assessed up to 3 minutes per assessment per participant.

The time required for the general-purpose artificial intelligence application and the anesthesiologist assessors to complete the visual (eyeball) and M-mode left ventricular ejection fraction assessments was recorded separately using a timer and reported in seconds. Assessment times were compared between the artificial intelligence and anesthesiologist methods.

During intraoperative TEE image review, from the start of each visual (eyeball) or M-mode LVEF assessment until the corresponding estimate is completed, assessed up to 3 minutes per assessment per participant.
Difference Between Intraoperative TEE and Preoperative TTE LVEF Assessments
Временное ограничение: From the available preoperative TTE assessment to the intraoperative TEE assessment during cardiac surgery

Left ventricular ejection fraction estimates obtained from intraoperative transesophageal echocardiography by the general-purpose artificial intelligence application and the blinded anesthesiologist assessors were compared with the available preoperative transthoracic echocardiography ejection fraction for the same participant. The difference between each intraoperative assessment and the preoperative transthoracic echocardiography value was evaluated.

From the available preoperative TTE assessment to the intraoperative TEE assessment during cardiac surgery

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

28 марта 2026 г.

Первичное завершение (Действительный)

22 августа 2026 г.

Завершение исследования (Действительный)

22 августа 2026 г.

Даты регистрации исследования

Первый отправленный

14 сентября 2026 г.

Впервые представлено, что соответствует критериям контроля качества

20 сентября 2026 г.

Первый опубликованный (Действительный)

25 сентября 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

25 сентября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

20 сентября 2026 г.

Последняя проверка

1 сентября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Описание плана IPD

Individual participant data will not be shared because external sharing of participant-level data was not included in the approved study protocol, ethics approval, or informed consent. Only aggregate study results will be reported.

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться