- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07935902
Effect of Different Adhesive Removal Techniques After Orthodontic Bracket Debonding on Postoperative Hypersensitivity: A Randomized Clinical Trial
The objective of this randomized clinical trial is to evaluate and compare the effect of four different residual adhesive removal techniques following orthodontic bracket debonding on postoperative tooth hypersensitivity. The study compares low-speed tungsten carbide burs against fiberglass burs, white stone burs, and rubber-impregnated polishing points. Postoperative hypersensitivity will be evaluated using a Visual Analogue Scale (VAS) with an air-blast stimulus test immediately after debonding, at 24 hours, and at 7 days follow-up.
Descripción general del estudio
Estado
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Asmaa Badr Abdelfatah, BDS
- Número de teléfono: +20 1148106593
- Correo electrónico: asmaa.abdelfatah@dentistry.cu.edu.eg
Copia de seguridad de contactos de estudio
- Nombre: Heba El-Deeb, PhD
- Número de teléfono: +20 106 610 9461
- Correo electrónico: heba.eldeeb@dentistry.cu.edu.eg
Ubicaciones de estudio
-
-
-
Cairo, Egipto
- Faculty of Dentistry, Cairo University
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Patients of any gender aged 15 to 45 years undergoing routine fixed labial orthodontic bracket removal across anterior and premolar teeth in both jaws.
- Systemically healthy patients.
- Good oral hygiene with a healthy, intact periodontium without clinical attachment loss or gingival recession.
- Patients capable of reliably recording subjective discomfort on a Visual Analogue Scale (VAS) and willing to attend follow-up visits.
- Sound fully erupted permanent incisors, canines, and premolars bonded with conventional stainless steel labial brackets.
- Labial enamel surfaces free of visible pre-existing enamel defects, structural hypoplasia, severe fluorosis, or restorations.
Exclusion Criteria:
- Active use of systemic analgesics, NSAIDs, corticosteroids, or centrally acting pain medications within 14 days prior to debonding.
- Use of desensitizing toothpastes, mouthwashes, or topical fluoride varnishes within 30 days prior to the trial.
- Heavy bruxism, clenching habits, or pathological wear/erosion extending into dentin.
- Pregnant or lactating female patients.
- Teeth with irreversible pulpitis, pulpal necrosis, history of endodontic treatment, or periapical pathology.
- Teeth with active carious lesions or exposed cervical dentin/cementum.
- Teeth with severe, deep enamel microcracks identified at baseline examination.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: Active Comparator: Low-Speed Tungsten Carbide Bur
Residual composite adhesive remnants on eligible teeth are cleaned using a 12-fluted low-speed tungsten carbide bur operated at 15,000-20,000 rpm under continuous water cooling. |
Composite resin is removed using a 12-fluted tapered low-speed tungsten carbide bur operated at 15,000-20,000 rpm under continuous air-water spray irrigation until all visible adhesive remnant is completely eliminated. |
|
Experimental: Fiberglass Bur
Residual composite adhesive remnants on eligible teeth are cleaned using a fiberglass bur operated at 15,000-20,000 rpm under continuous water cooling |
Composite resin remnants are eliminated using a fiberglass resin-removal bur operated at 15,000-20,000 rpm under continuous air-water spray irrigation until all visible material is completely removed. |
|
Experimental: White Stone Bur
Residual composite adhesive remnants on eligible teeth are cleaned using a fine-grit white stone bur (aluminum oxide) operated at 10,000-15,000 rpm under continuous water cooling. |
Composite resin remnants are removed using a fine-grit Arkansas white stone bur (aluminum oxide) operated at 10,000-15,000 rpm under continuous air-water spray irrigation until the enamel surface is clear. |
|
Experimental: Rubber-Impregnated Polishing Point
Residual composite adhesive remnants on eligible teeth are cleaned using a rubber-impregnated polishing point operated at 10,000-15,000 rpm under continuous water cooling |
Residual adhesive tags are removed and polished using a rubber-impregnated composite polishing point operated at 10,000-15,000 rpm under continuous air-water spray irrigation |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Postoperative Hypersensitivity
Periodo de tiempo: Baseline (immediately post-debonding, before clean-up), 24 hours, and 7 days post-adhesive removal.
|
Patient-reported pain and hypersensitivity evaluated using a Visual Analogue Scale (VAS) score ranging from 0 (No pain) to 10 (Unbearable severe pain) in response to a 2-second dental syringe air-blast stimulus test. |
Baseline (immediately post-debonding, before clean-up), 24 hours, and 7 days post-adhesive removal.
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Procedure Time
Periodo de tiempo: Immediately during the clean-up procedure.
|
Time taken to perform complete residual adhesive removal per tooth, measured using a stopwatch |
Immediately during the clean-up procedure.
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Director de estudio: Heba El-Deeb, PhD, Cairo to Department of Conservative Dentistry, Faculty of Dentistry, Cairo University .
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- CONS 3-4-1
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .