Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Clinical Evaluation of SHOFU FX-LC RMGI Restoration Versus FUJI II RGMI in Management of Anterior Carious Cervical Lesions

8 de noviembre de 2026 actualizado por: Salma Hany Mohamed Saeed, Cairo University

Clinical Evaluation of Acrylamide Based RMGI Restoration Versus Conventional Resin Modified Glass Ionomer in Management of Patients Having Anterior Carious Cervical Lesions: A Randomized Clinical Trial.

The development of resin-modified glass ionomers (RMGIs) represents a strategic evolution designed to augment the mechanical performance of conventional glass ionomers. By incorporating a resin matrix, these materials achieve notable physical improvements, including superior fracture toughness, increased resistance to occlusal wear, and higher resilience to moisture degradation, alongside the clinical advantage of a prolonged working time. (Hübel 2003)However, an excessive proportion of hydrophobic multifunctional monomers within the RMGI matrix suppresses the essential aqueous acid-base reaction.

To overcome conventional resin modified glass ionomer drawbacks, FX-LC tried to overcome it by incorporating a new multifunctional acrylamide monomer called New Generation Acrylamide monomer (NGA monomer) with which they claim that it exhibits high water solubility due to its four amide bonds (-CO-NH-) and demonstrates high polymerization reactivity, even in the presence of water. It has unique properties that are not found in conventional multifunctional monomers

Descripción general del estudio

Estado

Aún no reclutando

Tipo de estudio

Intervencionista

Inscripción (Estimado)

36

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Patient inclusion:

    1. Adult Patients age >18 years.
    2. Males or Females
    3. Patients with good likelihood of recall availability.

Tooth inclusion:

  1. Permanent anterior teeth with cervical Class V, carious lesions (ICDAS 3-5)
  2. Vital and with positive reaction to cold stimulus.
  3. Well-formed and fully erupted teeth.

Exclusion Criteria:

  • Patient exclusion:

    1. Participants with general/systemic illness.
    2. Pregnant or lactating females.
    3. Concomitant participation in another research study.
    4. Inability to comply with study procedures.
    5. Heavy Bruxism Habits.
    6. Last experience with allergic reactions against any components of the used materials.
    7. Patients receiving orthodontic treatment.

Tooth exclusion:

  1. Teeth with clinical symptoms of pulpitis such as spontaneous pain or sensitivity to pressure.
  2. Non-vital teeth, Fractured or cracked teeth.
  3. Secondary carious lesions.
  4. Hypocalcified or hypoplastic teeth

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: SHOFU FX-LC RMGI

After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds.

The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included.

FX-LC is RMGI which incorporates New Generation Acrylamide monomer, After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds.

The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included.

Light curing unit will be used to cure the material for 10 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction.

Comparador activo: FUJI II RMGI

Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included.

light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction.

FUJI II, Conventional resin modifies glass ionomer will bwe applied. Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included.

light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Periodo de tiempo
Clinical Performance assessing Biological, Mechanical and Esthetic Parameters Using Modified USPHS Criteria
Periodo de tiempo: Time Frame: Baseline, 6 months, 12 months, 18 months.
Time Frame: Baseline, 6 months, 12 months, 18 months.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de noviembre de 2026

Finalización primaria (Estimado)

1 de marzo de 2028

Finalización del estudio (Estimado)

1 de mayo de 2028

Fechas de registro del estudio

Enviado por primera vez

8 de noviembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

8 de noviembre de 2026

Publicado por primera vez (Actual)

13 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

13 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

8 de noviembre de 2026

Última verificación

1 de octubre de 2026

Más información

Términos relacionados con este estudio

Palabras clave

Otros números de identificación del estudio

  • 22051999

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir