Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Clinical Evaluation of SHOFU FX-LC RMGI Restoration Versus FUJI II RGMI in Management of Anterior Carious Cervical Lesions

8 de novembro de 2026 atualizado por: Salma Hany Mohamed Saeed, Cairo University

Clinical Evaluation of Acrylamide Based RMGI Restoration Versus Conventional Resin Modified Glass Ionomer in Management of Patients Having Anterior Carious Cervical Lesions: A Randomized Clinical Trial.

The development of resin-modified glass ionomers (RMGIs) represents a strategic evolution designed to augment the mechanical performance of conventional glass ionomers. By incorporating a resin matrix, these materials achieve notable physical improvements, including superior fracture toughness, increased resistance to occlusal wear, and higher resilience to moisture degradation, alongside the clinical advantage of a prolonged working time. (Hübel 2003)However, an excessive proportion of hydrophobic multifunctional monomers within the RMGI matrix suppresses the essential aqueous acid-base reaction.

To overcome conventional resin modified glass ionomer drawbacks, FX-LC tried to overcome it by incorporating a new multifunctional acrylamide monomer called New Generation Acrylamide monomer (NGA monomer) with which they claim that it exhibits high water solubility due to its four amide bonds (-CO-NH-) and demonstrates high polymerization reactivity, even in the presence of water. It has unique properties that are not found in conventional multifunctional monomers

Visão geral do estudo

Status

Ainda não está recrutando

Tipo de estudo

Intervencional

Inscrição (Estimado)

36

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Patient inclusion:

    1. Adult Patients age >18 years.
    2. Males or Females
    3. Patients with good likelihood of recall availability.

Tooth inclusion:

  1. Permanent anterior teeth with cervical Class V, carious lesions (ICDAS 3-5)
  2. Vital and with positive reaction to cold stimulus.
  3. Well-formed and fully erupted teeth.

Exclusion Criteria:

  • Patient exclusion:

    1. Participants with general/systemic illness.
    2. Pregnant or lactating females.
    3. Concomitant participation in another research study.
    4. Inability to comply with study procedures.
    5. Heavy Bruxism Habits.
    6. Last experience with allergic reactions against any components of the used materials.
    7. Patients receiving orthodontic treatment.

Tooth exclusion:

  1. Teeth with clinical symptoms of pulpitis such as spontaneous pain or sensitivity to pressure.
  2. Non-vital teeth, Fractured or cracked teeth.
  3. Secondary carious lesions.
  4. Hypocalcified or hypoplastic teeth

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: SHOFU FX-LC RMGI

After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds.

The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included.

FX-LC is RMGI which incorporates New Generation Acrylamide monomer, After rubber dam isolation, the prepared cavities will be conditioned using Dentin conditioner (GlasIonomer FX-LC Conditioner, Japan) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (SHOFU FX- LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds.

The mixture then is extruded directly out of capsule into prepared cavities with a capsule gun ensuring that no air bubbles will be included.

Light curing unit will be used to cure the material for 10 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction.

Comparador Ativo: FUJI II RMGI

Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included.

light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction.

FUJI II, Conventional resin modifies glass ionomer will bwe applied. Cavities will be conditioned using using Dentin conditioner (GC Dentine ConditionerS) 10-20% polyacrylic acid for 20 seconds then will be rinsed with copious amount of water for 15 seconds and dried with oil free compressed air for 5 seconds till the surface had a matte shiny appearance.

The (Fuji II LC) capsule will be inserted into a high-speed amalgamator (Mix 2000, Carlo De Giorgi, Milano, Italy) and triturated for 10 seconds. The mixture then is extruded directly out of capsule into prepared cavity with a capsule gun ensuring that no air bubbles will be included.

light curing unit will be used to cure the material for 20 seconds with a visible light unit at 470 nm, holding the light as close to the surface as possible, according to manufacturer instruction.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
Clinical Performance assessing Biological, Mechanical and Esthetic Parameters Using Modified USPHS Criteria
Prazo: Time Frame: Baseline, 6 months, 12 months, 18 months.
Time Frame: Baseline, 6 months, 12 months, 18 months.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de novembro de 2026

Conclusão Primária (Estimado)

1 de março de 2028

Conclusão do estudo (Estimado)

1 de maio de 2028

Datas de inscrição no estudo

Enviado pela primeira vez

8 de novembro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

8 de novembro de 2026

Primeira postagem (Real)

13 de novembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

13 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

8 de novembro de 2026

Última verificação

1 de outubro de 2026

Mais Informações

Termos relacionados a este estudo

Palavras-chave

Outros números de identificação do estudo

  • 22051999

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever