Development of Artificial Intelligence System for Detection and Diagnosis of Breast Lesion Using Mammography

24 juillet 2021 mis à jour par: Sun Ying-Shi, Peking University Cancer Hospital & Institute
This project aims to establish a comprehensive artificial intelligence system for detecting and qualitative diagnosing breast lesions. Mammary images will be used to construct a diagnosis method based on deep learning. The system is proposed to automatically analyze the type of mammary glands, automatically identify and mark all breast lesions on the mammography images, provide the malignancy probability judgment of the lesions, the BI-RADS classification and the clinical suggestion, and also automatically generate the structured diagnosis report.

Aperçu de l'étude

Statut

Complété

Intervention / Traitement

Description détaillée

This is a multi-center study.The project contains a retrospective part(3000 samples anticipated) and a prospective part(7000 samples anticipated). In the retrospective part, investigators collected subjects with mammary images to design the deep learning method and construct a detective and diagnostic model for breast lesions. In the prospective part, investigators validate the accuracy of the constructed deep learning method, and established artificial intelligence system focusing on mammary diagnosis. Investigators will also explore the application pattern of the artificial intelligence system in clinical practice.

Type d'étude

Observationnel

Inscription (Réel)

5809

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Beijing
      • Beijing, Beijing, Chine, 100142
        • Beijing Cancer Hospital
      • Beijing, Beijing, Chine
        • Beijing Chao Yang Women and Children's Health Hospital
      • Beijing, Beijing, Chine
        • Beijing Da Xing People's Hospital
      • Beijing, Beijing, Chine
        • Beijing Hang Tian Centre Hospital
      • Beijing, Beijing, Chine
        • Beijing Nan Jiao Cancer Hospital
      • Beijing, Beijing, Chine
        • Beijing Shi Jing Shan Hospital
      • Beijing, Beijing, Chine
        • Beijing Shun Yi Qu Hospital
      • Beijing, Beijing, Chine
        • Beijing Shun Yi Woman and Children Health Hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Femelle

Méthode d'échantillonnage

Échantillon de probabilité

Population étudiée

Women with suspected Breast Lesion

La description

Inclusion Criteria:

  • the X-ray images of the breast were complete
  • the results of pathological diagnosis or more than 2 years of mammography follow-up were available
  • subject signs informed consent(this item was only for prospective study cases)

Exclusion Criteria:

  • there exists pathological diagnosis of breast lesions when receiving mammography
  • there lacks pathological diagnosis or 2 years of mammography follow-up
  • subject withdraws(this item was only for prospective study cases)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
mammography group
women who receives mammography because of suspected breast lesion(s)
When a woman comes to the clinic to receive mammography. Then a radiologist will give a BI-RADS classification after reviewing the images. If a BI-RADS 4/5 is obtained, the woman will receive pathological biopsy to ensure there is a benign or malignant lesion. If a BI-RADS 3 is obtained, the woman will be followed up by a half-year interval until two year after the first mammography. At each follow up, she will receive mammography. If a BI-RADS 4/5 is obtained at follow up, she will receive pathological biopsy; if a BI-RADS 1/2/3 is obtained at follow up, she will be followed up by a half-year interval until two year. If a BI-RADS 1/2 is obtained at the first mammography, the woman will receive a second mammography after two year. During the study period, breast examination and results will be recorded for every subject. Radiologists will give the diagnosis with and without AI support.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
benign-malignant diagnosis accuracy
Délai: from the first mammography to pathological result obtained(an average of 3 weeks if mammography BI-RADS 4 or 5 obtained)
the accuracy of the AI model, radiogist with AI support, radiologist alone for binary diagnosis of a benign or malignant breast lesion according to pathology. If either one mammography of BI-RADS 4/5 in the first examination or during the two year' follow up examination is obtained,a pathological examination is performed, the lesion is judged benign or malignant according to pathological results.
from the first mammography to pathological result obtained(an average of 3 weeks if mammography BI-RADS 4 or 5 obtained)
benign-malignant diagnosis accuracy
Délai: from the first mammography to 2-year-after mammography
the accuracy of the AI model, radiogist with AI support, radiologist alone for binary diagnosis of a benign or malignant breast lesion according to follow up. If a 2-year mammography of BI-RADS 1/2/3 is obtained, the lesion is considered benign. If either one mammography of BI-RADS 4/5 during the two year is obtained,a pathological examination is performed to ensure the benign or malignant lesion
from the first mammography to 2-year-after mammography

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
lesion detection accuracy
Délai: from the first mammography to radiologist diagnosis (within 3 days after the mammography taken)
the detection rate of the constructed deep learning method for detecting benign or malignant breast lesion according to radiologist's subjective diagnosis or follow up as reference. If a radiologist suggests existence of a lesion at the first mammography or at each follow-up mammography during the 2-year period, it is considered that a lesion exists
from the first mammography to radiologist diagnosis (within 3 days after the mammography taken)

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Collaborateurs

Les enquêteurs

  • Chaise d'étude: Ying-Shi Sun, Professor, Peking University Cancer Hospital & Institute

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

5 avril 2018

Achèvement primaire (Réel)

4 mai 2020

Achèvement de l'étude (Réel)

4 mai 2020

Dates d'inscription aux études

Première soumission

17 avril 2018

Première soumission répondant aux critères de contrôle qualité

12 octobre 2018

Première publication (Réel)

17 octobre 2018

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

27 juillet 2021

Dernière mise à jour soumise répondant aux critères de contrôle qualité

24 juillet 2021

Dernière vérification

1 juillet 2021

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • BCA-AI

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner