Patients and methods: It is a prospective double blind study done on total 300 patients. Admitted with respiratory failure ARDS due to severe lung contusion. All of them selected to be ventilated for one week or more. Patients were randomly allocated in one of three groups each group contain 100 patients. Group A considered control extubated and follow our routine protocol, patients of group B reconnected to mechanical ventilation before extubation for one hour. patients of Group C extubated and immediately connected to NIV with BIPAP mode for 1 hour every 12 hours for 24 hours. Results: There was significant reduction in the number of patients had deterioration in conscious level in all the duration of the study in patients of both groups B and C compared to group A. Also significant reduction in the number of patients had deterioration in clinical parameters of respiration in all the duration of the study in patients of both groups B and C compared to group A as regards high respiratory rate, desaturation and development of hyperdynamic circulation (tachycardia and hypertension). significant reduction in the number of patients had multiple quadrant parenchymatous infiltration in all the duration of the study in patients of both groups B and C compared to group A. significant reduction in the number of patients had marked limitation to FEV1, FVC and MVV in all the duration of the study in patients of both groups B and C compared to group A. Conclusion: Use of either NIV every 12 hours for 24 hours or MV for one hour after fulfillment of weaning criteria reduces reintubation and post-extubation respiratory failure and decrease the ICU stay in critically ill patients with resolving ARDS due to severe lung trauma.

Aperçu de l'étude

Statut

Complété

Description détaillée

It is a prospective double-blind study done on total 300 patients. Admitted to King Abdulaziz specialist hospital in Taif, KSA. Between April 2019 and April 2020 with respiratory failure ARDS due to severe lung contusion with these criteria: hypoxic index less than 200, bilateral parenchymatous lung infiltrate, no any acute cardiac insult, failed to maintain SPO2 more than 90% with Non-Invasive Ventilation (NIV) or need of continuous NIV to maintain the previous saturation. This selected ARDS was due to lung contusion which diagnosed by Computerized tomography of the chest following chest trauma. All of them selected to be ventilated for one week or more and only those who showed full criteria of weaning from the ventilator enrolled in our study. Our criteria of weaning include fully conscious patients, hemodynamically stable without any inotropic support, hypoxic index(PAO2/FIO2) more than 200 calculated from the arterial blood gases (ABG), bicarbonate level in arterial blood more than 20 mmol/l, hemoglobin level more than 10 gm%, chest X ray less than one quadrant parenchymatous infiltration in each lung on Murray score of chest Xray, rapid shallow breathing index <105. Patients were randomly allocated in one of three groups each group contain 100 patients. Randomization sequence was created using Excel 2007 (Microsoft, Redmond, WA, USA) with a 1:1 allocation using random block sizes of 2 and 4 by an independent doctor. In this way, sequence generation and type of randomization can be expressed at the same time. Patients of group A extubated and followed our routine protocol of management post extubation which include Nebulization with Ventolin and epinephrine racemic every 8 hours for 48 hours, chest physical therapy (CPT) every 6 hours for 48 hours include clapping percussion with mechanical vibration and suction plus huffing or coughing and postural drainage if there was atelectasis seen by our routine chest X ray. Patients of group B reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS). 20 minutes before the end of this hour midazolam infusion discontinued and patients awaked. Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O. Then patients extubated and followed our previous protocol without the use of NIV.

Type d'étude

Observationnel

Inscription (Réel)

300

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Ta'if, Arabie Saoudite, 21944
        • King abd el Aziz specialist hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 65 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon de probabilité

Population étudiée

on total 300 patients. Admitted to King Abdulaziz specialist hospital in Taif, KSA. Between April 2019 and April 2020 with respiratory failure ARDS due to severe lung contusion with these criteria: hypoxic index less than 200, bilateral parenchymatous lung infiltrate, no any acute cardiac insult, failed to maintain SPO2 more than 90% with Non-Invasive Ventilation (NIV) or need of continuous NIV to maintain the previous saturation. This selected ARDS was due to lung contusion which diagnosed by Computerized tomography of the chest following chest trauma. All of them selected to be ventilated for one week or more and only those who showed full criteria of weaning from the ventilator enrolled in our study

La description

Inclusion Criteria:

  • respiratory failure ARDS due to severe lung contusion

Exclusion Criteria:

  • post arrest, deeply comatosed patients and children below 18 years

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: Cohorte
  • Perspectives temporelles: Éventuel

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Control group
extubated and weaning from the ventilator and followed our routine protocol of management post extubation without mechanical ventilation or BIPAP machine
reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS). 20 minutes before the end of this hour midazolam infusion discontinued and patients awaked. Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O. Then patients extubated and followed our previous protocol without the use
Autres noms:
  • dortoir
reconnected to mechanical ventilation before extubation for one hour with sedation
Invasive ventilation group
reconnected to mechanical ventilator before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS). 20 minutes before the end of this hour midazolam infusion discontinued and patients awaked. Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O. Then patients extubated and followed our previous protocol without the use of NIV.
reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS). 20 minutes before the end of this hour midazolam infusion discontinued and patients awaked. Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O. Then patients extubated and followed our previous protocol without the use
Autres noms:
  • dortoir
reconnected to mechanical ventilation before extubation for one hour with sedation
non invasive ventilation group
following the same previous protocol done after extubation with immediate connection to NIV with BIPAP mode for 1 hour and repeated every 12hours for 48 hours, BIPAP adjusted in our study by FIO2 40%, PEEP 8 cmH2O, Pressure support of 15 cmH2O.
reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS). 20 minutes before the end of this hour midazolam infusion discontinued and patients awaked. Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O. Then patients extubated and followed our previous protocol without the use
Autres noms:
  • dortoir
reconnected to mechanical ventilation before extubation for one hour with sedation

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
number of patients re-intubated within 48 hours and shorten the duration of ICU stay
Délai: 48 hours
monitoring hemodynamics, oxygenation, and conscious level in the studied duration
48 hours

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

10 avril 2019

Achèvement primaire (Réel)

2 avril 2020

Achèvement de l'étude (Réel)

20 avril 2020

Dates d'inscription aux études

Première soumission

20 mai 2020

Première soumission répondant aux critères de contrôle qualité

20 mai 2020

Première publication (Réel)

26 mai 2020

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

27 mai 2020

Dernière mise à jour soumise répondant aux critères de contrôle qualité

25 mai 2020

Dernière vérification

1 mai 2020

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

Non

Description du régime IPD

see if both iv or niv after fullfilling the criteria of extubation in ARDS patients can prevent reintubation

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Oui

Étudie un produit d'appareil réglementé par la FDA américaine

Oui

produit fabriqué et exporté des États-Unis.

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner