Non Invasive and Invasive Ventilation Post Extubation
25 mei 2020 bijgewerkt door: King Abdul Aziz Specialist Hospital
Comparative Study Between Usage of NIV Versus MV for One Hour After Fulfillment of Weaning Criteria From Ventilation on Re-intubation in Post-traumatic ARDS
Patients and methods: It is a prospective double blind study done on total 300 patients.
Admitted with respiratory failure ARDS due to severe lung contusion.
All of them selected to be ventilated for one week or more.
Patients were randomly allocated in one of three groups each group contain 100 patients.
Group A considered control extubated and follow our routine protocol, patients of group B reconnected to mechanical ventilation before extubation for one hour.
patients of Group C extubated and immediately connected to NIV with BIPAP mode for 1 hour every 12 hours for 24 hours.
Results: There was significant reduction in the number of patients had deterioration in conscious level in all the duration of the study in patients of both groups B and C compared to group A. Also significant reduction in the number of patients had deterioration in clinical parameters of respiration in all the duration of the study in patients of both groups B and C compared to group A as regards high respiratory rate, desaturation and development of hyperdynamic circulation (tachycardia and hypertension).
significant reduction in the number of patients had multiple quadrant parenchymatous infiltration in all the duration of the study in patients of both groups B and C compared to group A. significant reduction in the number of patients had marked limitation to FEV1, FVC and MVV in all the duration of the study in patients of both groups B and C compared to group A. Conclusion: Use of either NIV every 12 hours for 24 hours or MV for one hour after fulfillment of weaning criteria reduces reintubation and post-extubation respiratory failure and decrease the ICU stay in critically ill patients with resolving ARDS due to severe lung trauma.
Studie Overzicht
Toestand
Voltooid
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
It is a prospective double-blind study done on total 300 patients.
Admitted to King Abdulaziz specialist hospital in Taif, KSA.
Between April 2019 and April 2020 with respiratory failure ARDS due to severe lung contusion with these criteria: hypoxic index less than 200, bilateral parenchymatous lung infiltrate, no any acute cardiac insult, failed to maintain SPO2 more than 90% with Non-Invasive Ventilation (NIV) or need of continuous NIV to maintain the previous saturation.
This selected ARDS was due to lung contusion which diagnosed by Computerized tomography of the chest following chest trauma.
All of them selected to be ventilated for one week or more and only those who showed full criteria of weaning from the ventilator enrolled in our study.
Our criteria of weaning include fully conscious patients, hemodynamically stable without any inotropic support, hypoxic index(PAO2/FIO2) more than 200 calculated from the arterial blood gases (ABG), bicarbonate level in arterial blood more than 20 mmol/l, hemoglobin level more than 10 gm%, chest X ray less than one quadrant parenchymatous infiltration in each lung on Murray score of chest Xray, rapid shallow breathing index <105.
Patients were randomly allocated in one of three groups each group contain 100 patients.
Randomization sequence was created using Excel 2007 (Microsoft, Redmond, WA, USA) with a 1:1 allocation using random block sizes of 2 and 4 by an independent doctor.
In this way, sequence generation and type of randomization can be expressed at the same time.
Patients of group A extubated and followed our routine protocol of management post extubation which include Nebulization with Ventolin and epinephrine racemic every 8 hours for 48 hours, chest physical therapy (CPT) every 6 hours for 48 hours include clapping percussion with mechanical vibration and suction plus huffing or coughing and postural drainage if there was atelectasis seen by our routine chest X ray.
Patients of group B reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS).
20 minutes before the end of this hour midazolam infusion discontinued and patients awaked.
Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O.
Then patients extubated and followed our previous protocol without the use of NIV.
Studietype
Observationeel
Inschrijving (Werkelijk)
300
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
-
Ta'if, Saoedi-Arabië, 21944
- King abd el Aziz specialist hospital
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
18 jaar tot 65 jaar (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Nee
Geslachten die in aanmerking komen voor studie
Allemaal
Bemonsteringsmethode
Kanssteekproef
Studie Bevolking
on total 300 patients.
Admitted to King Abdulaziz specialist hospital in Taif, KSA.
Between April 2019 and April 2020 with respiratory failure ARDS due to severe lung contusion with these criteria: hypoxic index less than 200, bilateral parenchymatous lung infiltrate, no any acute cardiac insult, failed to maintain SPO2 more than 90% with Non-Invasive Ventilation (NIV) or need of continuous NIV to maintain the previous saturation.
This selected ARDS was due to lung contusion which diagnosed by Computerized tomography of the chest following chest trauma.
All of them selected to be ventilated for one week or more and only those who showed full criteria of weaning from the ventilator enrolled in our study
Beschrijving
Inclusion Criteria:
- respiratory failure ARDS due to severe lung contusion
Exclusion Criteria:
- post arrest, deeply comatosed patients and children below 18 years
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: Cohort
- Tijdsperspectieven: Prospectief
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Control group
extubated and weaning from the ventilator and followed our routine protocol of management post extubation without mechanical ventilation or BIPAP machine
|
reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS).
20 minutes before the end of this hour midazolam infusion discontinued and patients awaked.
Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O.
Then patients extubated and followed our previous protocol without the use
Andere namen:
reconnected to mechanical ventilation before extubation for one hour with sedation
|
|
Invasive ventilation group
reconnected to mechanical ventilator before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS).
20 minutes before the end of this hour midazolam infusion discontinued and patients awaked.
Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O.
Then patients extubated and followed our previous protocol without the use of NIV.
|
reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS).
20 minutes before the end of this hour midazolam infusion discontinued and patients awaked.
Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O.
Then patients extubated and followed our previous protocol without the use
Andere namen:
reconnected to mechanical ventilation before extubation for one hour with sedation
|
|
non invasive ventilation group
following the same previous protocol done after extubation with immediate connection to NIV with BIPAP mode for 1 hour and repeated every 12hours for 48 hours, BIPAP adjusted in our study by FIO2 40%, PEEP 8 cmH2O, Pressure support of 15 cmH2O.
|
reconnected to mechanical ventilation before extubation for one hour with sedation with midazolam 3-5 milligram/hour intravenous infusion to achieve score 0 or -1on Richmond Agitation - Sedation Scale (RASS).
20 minutes before the end of this hour midazolam infusion discontinued and patients awaked.
Patient put on mechanical ventilation (MV) with the following parameters, FIO2 40%, pressure SIMV mode, PEEP 8 cmH2O, Pressure support 15 cmH2O, Respiratory rate 14/min, Peak inspiratory pressure (PIP) of 35 cmH2O.
Then patients extubated and followed our previous protocol without the use
Andere namen:
reconnected to mechanical ventilation before extubation for one hour with sedation
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
number of patients re-intubated within 48 hours and shorten the duration of ICU stay
Tijdsspanne: 48 hours
|
monitoring hemodynamics, oxygenation, and conscious level in the studied duration
|
48 hours
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start (Werkelijk)
10 april 2019
Primaire voltooiing (Werkelijk)
2 april 2020
Studie voltooiing (Werkelijk)
20 april 2020
Studieregistratiedata
Eerst ingediend
20 mei 2020
Eerst ingediend dat voldeed aan de QC-criteria
20 mei 2020
Eerst geplaatst (Werkelijk)
26 mei 2020
Updates van studierecords
Laatste update geplaatst (Werkelijk)
27 mei 2020
Laatste update ingediend die voldeed aan QC-criteria
25 mei 2020
Laatst geverifieerd
1 mei 2020
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
- Ziekten van de luchtwegen
- Ademhalingsstoornissen
- Tekenen en symptomen, ademhaling
- Ademhalingsinsufficiëntie
- Hypoxie
- Fysiologische effecten van medicijnen
- Neurotransmitter agenten
- Moleculaire mechanismen van farmacologische werking
- Depressiva van het centrale zenuwstelsel
- Anesthesie, intraveneus
- Anesthesie, generaal
- Anesthesie
- Rustgevende agenten
- Psychotrope medicijnen
- Hypnotica en sedativa
- Adjuvantia, anesthesie
- Middelen tegen angst
- GABA-modulatoren
- GABA-agenten
- Midazolam
Andere studie-ID-nummers
- ICU-19-20
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Nee
Beschrijving IPD-plan
see if both iv or niv after fullfilling the criteria of extubation in ARDS patients can prevent reintubation
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Ja
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Ja
product vervaardigd in en geëxporteerd uit de V.S.
Nee
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .