- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT04572633
Le système HistoSonics pour le traitement des tumeurs hépatiques primaires et métastatiques par histotripsie (#HOPE4LIVER US)
Le système HistoSonics pour le traitement des tumeurs hépatiques primaires et métastatiques par histotripsie (#HOPE4LIVER US)
This trial is a single arm, non-randomized prospective trial. The objective of this trial is to evaluate the efficacy and safety of the HistoSonics System for the treatment of primary or metastatic tumors located in the liver. The co-primary safety and efficacy endpoints must be met for the trial to be successful.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
This trial is a single arm, non-randomized, multicenter, prospective trial. Following histotripsy treatment of liver tumor(s), subjects will undergo imaging ≤36 hours post-index procedure to determine technical success. Subjects will then be followed for 30 days. Additionally, subjects will be evaluated at 6 months and followed annually for up to five (5) years post-index procedure.
The #HOPE4LIVER US trial required pooling data from #HOPE4LIVER US and #HOPE4LIVER EU/UK (NCT04573881). Subjects were treated with the same intervention (HistoSonics System) using identical protocols tailored to the regulatory requirements for each geography.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Florida
-
Miami, Florida, États-Unis, 33176
- Miami Cancer Institute
-
Tampa, Florida, États-Unis, 33606
- Tampa General Hospital
-
-
Illinois
-
Chicago, Illinois, États-Unis, 60637
- University of Chicago
-
-
Kansas
-
Kansas City, Kansas, États-Unis, 66160
- University of Kansas Medical Center
-
-
Michigan
-
Ann Arbor, Michigan, États-Unis, 48109-5030
- University of Michigan Hospital
-
-
Wisconsin
-
Madison, Wisconsin, États-Unis, 53792-3252
- University Hospital - UW Health
-
Milwaukee, Wisconsin, États-Unis, 53226
- Medical College of Wisconsin/Froedtert Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
-
Subject is ≥18 years of age
-
Subject has signed the Ethics Committee (EC) or Institutional Review Board (IRB) approved trial Informed Consent Form (ICF) prior to any trial related tests/procedures and is willing to comply with trial procedures and required follow-up assessments
-
Subject is diagnosed with hepatocellular carcinoma (HCC) or liver metastases (mets) from other primary cancers
-
Subject is able to undergo general anesthesia
-
Subject has a Child-Pugh Score of A or B
-
Subject has an Eastern Cooperative Oncology Group Performance Status (ECOG PS) grade 0-2 at baseline screening
-
Subject meets the following functional criteria, ≤7 days prior to the index-procedure:
- Liver function: Alanine transaminase (ALT) and Aspartate transaminase (AST) <2.5x upper limit of normal (ULN) and/or bilirubin <2.5 ULN, and
- Renal function: serum creatinine <2x ULN, and
- Hematologic function: neutrophil count >1.0 x 10^9/L and platelet >50 x 10^9/L
-
Subject has an International Normalized Ratio (INR) score of <2.0 , ≤7 days prior to the index procedure
-
Subject has not responded to and/or has relapsed and/or is intolerant of other available therapies including locoregional therapies, chemotherapy, immunotherapy and targeted therapies
-
The tumor(s) selected for histotripsy treatment must be ≤3 cm in longest diameter
-
Subject has an adequate acoustic window to visualize targeted tumor(s) using ultrasound imaging
-
Subject has a maximum of three (3) tumors to be treated with histotripsy during the index procedure, regardless of how many tumors the subject has.
Exclusion Criteria:
- Subject is pregnant or planning to become pregnant or nursing (lactating) during the trial period
- Subject is enrolled in another investigational trial and/or is taking investigational medication and/or has been treated with an investigational device ≤30-days prior to planned index procedure date
- In the Investigator's opinion, the subject has co-morbid disease(s) or condition(s) that would cause undue risk and preclude safe use of the HistoSonics System
- Subject has a serum creatinine >2.0 mg/dL or estimated glomerular filtration rate (EGFR) <30, unless on dialysis
- Subject has major surgical procedure or significant traumatic injury ≤2 weeks prior to the planned index procedure or not fully recovered (CTCAE grade 1 or better) from side effects/complications of such procedure or trauma
- Subject has not recovered to common terminology criteria for adverse events (CTCAE) grade 1 or better from any adverse effects (except alopecia, fatigue, nausea, vomiting and peripheral neuropathy) related to previous anti-cancer therapy
- Subject has a history of, or suspected to have, bleeding disorders that are uncorrectable
- Subject has coagulopathy that is uncorrectable
- Subject has a planned cancer treatment (e.g. resection, chemotherapy, etc.) after the planned index-procedure date and prior to completion of the 30-day follow-up visit
- Subject has previous treatment with bevacizumab that has not been discontinued >40 days prior to the planned index-procedure date
- Subject has planned bevacizumab treatment prior to completion of the 30-day follow-up visit
- Subject has previous treatments with chemotherapy and/or radiotherapy that has not been discontinued ≥2 weeks prior to the planned index-procedure date and has not recovered (CTCAE grade 1 or better) from related toxicity (except alopecia and peripheral neuropathy)
- Subject has previous treatment with immunotherapies that has not been discontinued ≥4 weeks prior to the index-procedure and has not recovered from related toxicity (CTCAE grade 1 or better)
- Subject has a life expectancy less than six (<6) months
- In the opinion of the Investigator, histotripsy is not a treatment option for the subject
- Subject has a concurrent condition that, in the investigator's opinion, could jeopardize the safety of the subject or compliance with the protocol
- Subjects' tumor(s) is not treatable by the System's working ranges (refer to User Manual)
- Subject has a known sensitivity to contrast media and cannot be adequately pre-medicated
- Subjects' target tumor(s) has/have had prior locoregional therapy (e.g. ablation, embolization, radiation)
- Subject is eligible for surgical resection
- Targeted tumor(s) treatment volume overlaps a non-targeted tumor visible via imaging
- The targeted tumor(s) is not clearly visible with diagnostic ultrasound and computed tomography (CT) or magnetic resonance (MR) imaging
- The targeted tumor(s) is located in liver segment 1
- The Planned Treatment Volume intended to cover the targeted tumor includes or encompasses any portion of the main portal vein, common hepatic duct, common bile duct, gallbladder or stomach/bowel.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Système HistoSonics
|
The HistoSonics System (System) is intended for the destruction of liver tissue using histotripsy, a non-thermal, mechanical process using focused ultrasound.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Primary Efficacy: Technical Success
Délai: ≤36 hours post-index procedure
|
Technical success, defined as the treatment volume/treatment dimensions being greater than or equal to the targeted tumor, and with complete tumor coverage, via computed tomography (CT) or magnetic resonance (MR) imaging. [Core Laboratory Adjudicated] Primary efficacy was assessed per tumor with a performance goal of greater than 70%. Primary efficacy was assessed after the first forty (40) consecutive evaluable subjects were enrolled. Evaluable subjects had sufficient CT or MR imaging data to allow the independent core laboratory to evaluate technical success. |
≤36 hours post-index procedure
|
|
Primary Safety: Procedure-Related Major Complications
Délai: 30 days post-index procedure
|
Number of index procedure related major complications, including device-related events defined as Common Terminology Criteria for Adverse Events (CTCAE) grade 3 or higher toxicities observed up to 30-days post index-procedure. [Clinical Events Committee Adjudicated] Primary safety was assessed per participant with a performance goal of less than 25%. Primary safety was assessed on all subjects enrolled, after the first forty (40) consecutive subjects evaluable for technical success were enrolled. Evaluable subjects had sufficient CT or MR imaging data to allow the independent core laboratory to evaluate technical success. Enrollment of 44 total subjects was required to assess forty (40) subjects evaluable for technical success. |
30 days post-index procedure
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Secondary Efficacy: Technique Efficacy
Délai: 30 days post-index procedure
|
Technique efficacy, defined as the lack of a nodular or mass-like area of enhancement within or along the edge of the treatment volume assessed via CT or MR imaging at 30-days post-procedure. [Core Laboratory Adjudicated] |
30 days post-index procedure
|
|
Secondary Safety: All Adverse Events
Délai: 30 days post-index procedure
|
Number of adverse events (serious and non-serious) reported within 30 days post-index procedure. [Clinical Events Committee Adjudicated] |
30 days post-index procedure
|
|
Technical Success
Délai: ≤36 hours post-index procedure
|
Technical success, defined as the treatment volume/treatment dimensions being greater than or equal to the targeted tumor, and with complete tumor coverage, via computed tomography (CT) or magnetic resonance (MR) imaging. [Core Laboratory Adjudicated] |
≤36 hours post-index procedure
|
|
Procedure-Related Major Complications
Délai: 30 days post-index procedure
|
Number of index procedure related major complications, including device-related events defined as Common Terminology Criteria for Adverse Events (CTCAE) grade 3 or higher toxicities observed up to 30-days post index-procedure. [Clinical Events Committee Adjudicated] |
30 days post-index procedure
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Timothy J Ziemlewicz, MD, University of Wisconsin, Madison
- Chercheur principal: Clifford S Cho, MD, University of Michigan
Publications et liens utiles
Publications générales
- Mendiratta-Lala M, Wiggermann P, Pech M, Serres-Creixams X, White SB, Davis C, Ahmed O, Parikh ND, Planert M, Thormann M, Xu Z, Collins Z, Narayanan G, Torzilli G, Cho C, Littler P, Wah TM, Solbiati L, Ziemlewicz TJ. The #HOPE4LIVER Single-Arm Pivotal Trial for Histotripsy of Primary and Metastatic Liver Tumors. Radiology. 2024 Sep;312(3):e233051. doi: 10.1148/radiol.233051.
- Ziemlewicz TJ, Critchfield JJ, Mendiratta-Lala M, Wiggermann P, Pech M, Serres-Creixams X, Lubner M, Wah TM, Littler P, Davis CR, Narayanan G, White SB, Ahmed O, Collins ZS, Parikh ND, Planert M, Thormann M, Torzilli G, Solbiati LA, Cho CS. The #HOPE4LIVER Single-arm Pivotal Trial for Histotripsy of Primary and Metastatic Liver Tumors: One-year Update of Clinical Outcomes. Ann Surg. 2025 Dec 1;282(6):908-916. doi: 10.1097/SLA.0000000000006720. Epub 2025 Apr 9.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- CSP1427
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .