Contribution of New Generation Oxford Nanopore-type High-throughput Sequencing in the Diagnostic Strategy of Neurogenetic Diseases. (NEURONGS3)
Since 2012, NGS sequencing of long fragments or long reads has developed in various fields of research and today presents itself as a very promising alternative solution in the analysis of repeat amplifications. The Oxford Nanopore NGS automaton offers the prospect of bringing together 1st and 2nd line analyzes of all loci potentially indicated in neurogenetics at the same time. The project aims to compare the use of this new technology with methods currently used in reference laboratories.
The main objective is to evaluate the ability of next-generation high-throughput Oxford Nanopore-type sequencing (NEURONGS3) to diagnose 9 neurogenetic diseases compared to reference protocols via PCR (+/- Southern blot).
The secondary objective is to evaluate the repeatability of the NGS (intra-sample reproducibility) analysis in the diagnosis of 8 neurogenetic diseases.
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Since 2012, NGS sequencing of long fragments or long reads has developed in various fields of research and today presents itself as a very promising alternative solution in the analysis of repeat amplifications. The Oxford Nanopore NGS automaton offers the prospect of bringing together 1st and 2nd line analyzes of all loci potentially indicated in neurogenetics at the same time. The project aims to compare the use of this new technology with methods currently used in reference laboratories.
Multicenter cross-sectional early phase diagnostic study on already existing biological collections. Analyzes with the new technique (NGS) will be carried out blinded to the results obtained with the current reference algorithm based on the sequential performance of PCRs The main objective is to evaluate the ability of next-generation high-throughput Oxford Nanopore-type sequencing (NEURONGS3) to diagnose 9 neurogenetic diseases compared to reference protocols via PCR (+/- Southern blot).
The secondary objective is to evaluate the repeatability of the NGS (intra-sample reproducibility) analysis in the diagnosis of 8 neurogenetic diseases.
Type d'étude
Inscription (Anticipé)
Contacts et emplacements
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- minors, adults and protected adults.
- Subject carrying an amplification of nucleotide repeats in one of the following 9 genes FMR1, DMPK, ZNF9, SCA2, JPH3, HD, FXN, C9ORF72, RFC1
- DNA available in sufficient quantity (5 to 10 µg)
Exclusion Criteria:
- DNA degraded or of medium size <30kb,
- Patient objection to research - This patient objection must be reached to the center's investigator within 1 maximum period of 1 month after sending the information note.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Proportion of patients tested positive by Next Generation Sequencing among all the patients tested positive by the current algorithm based on PCRs
Délai: through study completion, an average of 2 years
|
For each of the 9 considered diseases, the proportion will be established as well as its 95% confidence interval.
|
through study completion, an average of 2 years
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Difference between the number of repetition amplifications found by the Next Generation Sequencing method and the number of repetition amplifications found by the PCR diagnosis method
Délai: through study completion, an average of 2 years
|
For each of the 9 considered diseases, the number of repetition amplifications found by the Next Generation Sequencing method will be compared to the number of repetition amplifications found by the PCR diagnosis method using the Bland et Altman graphs.
The average and standard deviation of the difference will be calculated.
|
through study completion, an average of 2 years
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Cyril GOIZET, University Hospital, Bordeaux
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Anticipé)
Achèvement primaire (Anticipé)
Achèvement de l'étude (Anticipé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- CHUBX 2019/51
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .