- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT04621422
Contribution of New Generation Oxford Nanopore-type High-throughput Sequencing in the Diagnostic Strategy of Neurogenetic Diseases. (NEURONGS3)
Since 2012, NGS sequencing of long fragments or long reads has developed in various fields of research and today presents itself as a very promising alternative solution in the analysis of repeat amplifications. The Oxford Nanopore NGS automaton offers the prospect of bringing together 1st and 2nd line analyzes of all loci potentially indicated in neurogenetics at the same time. The project aims to compare the use of this new technology with methods currently used in reference laboratories.
The main objective is to evaluate the ability of next-generation high-throughput Oxford Nanopore-type sequencing (NEURONGS3) to diagnose 9 neurogenetic diseases compared to reference protocols via PCR (+/- Southern blot).
The secondary objective is to evaluate the repeatability of the NGS (intra-sample reproducibility) analysis in the diagnosis of 8 neurogenetic diseases.
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Since 2012, NGS sequencing of long fragments or long reads has developed in various fields of research and today presents itself as a very promising alternative solution in the analysis of repeat amplifications. The Oxford Nanopore NGS automaton offers the prospect of bringing together 1st and 2nd line analyzes of all loci potentially indicated in neurogenetics at the same time. The project aims to compare the use of this new technology with methods currently used in reference laboratories.
Multicenter cross-sectional early phase diagnostic study on already existing biological collections. Analyzes with the new technique (NGS) will be carried out blinded to the results obtained with the current reference algorithm based on the sequential performance of PCRs The main objective is to evaluate the ability of next-generation high-throughput Oxford Nanopore-type sequencing (NEURONGS3) to diagnose 9 neurogenetic diseases compared to reference protocols via PCR (+/- Southern blot).
The secondary objective is to evaluate the repeatability of the NGS (intra-sample reproducibility) analysis in the diagnosis of 8 neurogenetic diseases.
Studietype
Inschrijving (Verwacht)
Contacten en locaties
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- minors, adults and protected adults.
- Subject carrying an amplification of nucleotide repeats in one of the following 9 genes FMR1, DMPK, ZNF9, SCA2, JPH3, HD, FXN, C9ORF72, RFC1
- DNA available in sufficient quantity (5 to 10 µg)
Exclusion Criteria:
- DNA degraded or of medium size <30kb,
- Patient objection to research - This patient objection must be reached to the center's investigator within 1 maximum period of 1 month after sending the information note.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Proportion of patients tested positive by Next Generation Sequencing among all the patients tested positive by the current algorithm based on PCRs
Tijdsspanne: through study completion, an average of 2 years
|
For each of the 9 considered diseases, the proportion will be established as well as its 95% confidence interval.
|
through study completion, an average of 2 years
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Difference between the number of repetition amplifications found by the Next Generation Sequencing method and the number of repetition amplifications found by the PCR diagnosis method
Tijdsspanne: through study completion, an average of 2 years
|
For each of the 9 considered diseases, the number of repetition amplifications found by the Next Generation Sequencing method will be compared to the number of repetition amplifications found by the PCR diagnosis method using the Bland et Altman graphs.
The average and standard deviation of the difference will be calculated.
|
through study completion, an average of 2 years
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Cyril GOIZET, University Hospital, Bordeaux
Studie record data
Bestudeer belangrijke data
Studie start (Verwacht)
Primaire voltooiing (Verwacht)
Studie voltooiing (Verwacht)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- CHUBX 2019/51
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .