- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07564258
Estimation of P0.1 Using Ultrasound Indexes of Diaphragm Function (PoccUS)
Estimation of Airway Occlusion Pressure at 100 ms Using Ultrasound Indexes of Diaphragm Function
Occlusion pressure at 100 ms (P0.1) is a reliable and non-invasive index of inspiratory drive that can be measured easily on most ventilator. Unfortunately, P0.1 cannot be measured reliably in non-intubated patients. In those receiving non-invasive ventilation, the measurement of P0.1 might be inaccurate due to leaks. P0.1 cannot be measured at all in patients receiving high-flow nasal canulae (HFNC).
Ultrasound indices of diaphragm contractile function, namely diaphragm excursion, velocity and thickening fraction, could be reliable and non-invasive proxies of respiratory drive in non-intubated patient.
Our hypothesis is that ultrasound indices of diaphragm function may reliably estimate P0.1. To validate this hypothesis, theses indices will be measured simultaneously with P0.1 in intubated patients, during diaphragm loading conditions similar to spontaneous breathing: the spontaneous breathing trial (SBT). The SBT is used to evaluate if patients can breathe without the assistance provided by the ventilator, and thus, be weaned from mechanical ventilation.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- - Age ≥ 18 years old
- Patient intubated or tracheostomized
- Decision by the clinician in charge to initiate a SBT
- After information, the patient or next of kind did not refuse to participate (according to the French law, written informed consent is waived)
Exclusion Criteria:
- - Suspicion of diaphragmatic nerves injury
- Preexisting neuromuscular disease
- Spinal cord injury above C5
- Neuromuscular blockade within last 24 hours
- Body mass index > 40 kg/m2
- Pregnancy or breast feeding
- Patient under legal protection
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
P0.1 and Peak contraction velocity 5 minutes after the initiation of the SBT
Délai: 5 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to peak contraction velocity of the diaphragm, measured by subcostal ultrasound in TDI-mode
|
5 minutes after the initiation of the SBT
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
P0.1 and EXdi
Délai: Immediately after the initiation of the SBT then 5, 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to maximal excursion of the diaphragm, measured by subcostal ultrasound in M-mode
|
Immediately after the initiation of the SBT then 5, 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and Peak contraction velocity
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to peak contraction velocity of the diaphragm, measured by subcostal ultrasound in TDI-mode
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and EXdi,0.1
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to excursion of the diaphragm measured 100 ms after the beginning of the inspiration, measured by subcostal ultrasound in M-mode
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and Velocity Time Integral
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to velocity time integral of the diaphragm, measured by subcostal ultrasound in TDI-mode
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and Peak relaxation velocity
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to peak relaxation velocity of the diaphragm, measured by subcostal ultrasound in TDI-mode
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and Peak relaxation rate
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to peak relaxation rate of the diaphragm, measured by subcostal ultrasound in TDI-mode
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and TFdi
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to thickening fraction of the diaphragm, measured by intercostal ultrasound in M-mode.
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
|
P0.1 and mean thickening velocity
Délai: Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Airway occlusion pressure measured 100 ms after the initiation of the inspiration, compared to mean thickening velocity of the diaphragm, measured by intercostal ultrasound in M-mode.
|
Immediately after the initiation of the SBT then 10, 15, 20, 25 and 30 minutes after the initiation of the SBT
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- APHP260589
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
The procedures carried out with the French data privacy authority (CNIL, Commission nationale de l'informatique et des libertés) do not provide for the transmission of the database, nor do the information and consent documents signed by the patients.
Consultation by the editorial board or interested researchers of individual participant data that underlie the results reported in the article after deidentification may nevertheless be considered, subject to prior determination of the terms and conditions of such consultation and in respect for compliance with the applicable regulations.
Délai de partage IPD
Critères d'accès au partage IPD
Type d'informations de prise en charge du partage d'IPD
- PROTOCOLE D'ÉTUDE
- CIF
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .