Pilot Study on the Feasibility of High-energy Collimation With Optimized Geometry on a VERITON™ CZT Camera (HELIOS)
Functional imaging using scintigraphy plays a major role in the diagnosis and monitoring of many diseases, particularly thanks to its ability to perform whole-body examinations with high contrast. The indications and use of scintigraphy have increased in recent years, particularly in connection with the development of internal vectorized radiotherapy. This therapeutic approach is based on the administration of radiotracers that enable targeted irradiation of tumor cells, whose biodistribution throughout the body can be analyzed and quantified using scintigraphy, particularly with iodine-131 and lutetium-177.
The recent boom in scintigraphy is also linked to the development of new 360° geometry CZT-SPECT cameras, which enable rapid tomographic acquisitions of the entire body with significantly improved image quality compared to conventional cameras. These systems use mobile CZT semiconductor detectors that dynamically scan the anatomical regions of interest.
CZT detectors are combined with a collimation system consisting of tungsten septa, which are essential for the directional filtering of gamma photons. Unlike conventional scintigraphic cameras, where collimators can be changed or adjusted according to the energy of the detected photons, CZT-SPECT 360° cameras generally rely on fixed collimation, which cannot be changed.
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Functional imaging using scintigraphy plays a major role in the diagnosis and monitoring of many diseases, particularly thanks to its ability to perform whole-body examinations with high contrast. The indications and use of scintigraphy have increased in recent years, particularly in connection with the development of internal vectorized radiotherapy. This therapeutic approach is based on the administration of radiotracers that enable targeted irradiation of tumor cells, whose biodistribution throughout the body can be analyzed and quantified using scintigraphy, particularly with iodine-131 and lutetium-177.
The recent boom in scintigraphy is also linked to the development of new 360° geometry CZT-SPECT cameras, which enable rapid tomographic acquisitions of the entire body with significantly improved image quality compared to conventional cameras. These systems use mobile CZT semiconductor detectors that dynamically scan the anatomical regions of interest.
CZT detectors are combined with a collimation system consisting of tungsten septa, which are essential for the directional filtering of gamma photons. Unlike conventional scintigraphic cameras, where collimators can be changed or adjusted according to the energy of the detected photons, CZT-SPECT 360° cameras generally rely on fixed collimation, which cannot be changed.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Anne-Sophie Hue Project Manager, MSc
- Numéro de téléphone: +33.3.83.15.34.75
- E-mail: a.hue@chru-nancy.fr
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- patients with multiple known lesions (≥ 2 metastases or lesions of other types) who, as part of their clinical management, require either (i) a 99mTc-HDP bone scan, or (ii) a post-therapeutic 177Lu-PSMA scan, or (iii) a post-therapeutic 131I scintigraphy.
- Person who has undergone a preliminary clinical examination appropriate for clinical research.
- Adult subject who has received complete information about the research and has signed the informed consent form.
- General condition, WHO ≤ 2, and ability to remain lying down without moving for nearly an hour.
Exclusion Criteria:
- Subjects with a contraindication, according to the target examination group, to injection of 99mTc-HDP (Technescan HDP, Curium Pharma), 177Lu-PSMA (Pluvicto®, Novartis), or 131I (131I sodium iodide for therapy, Curium Pharma) .
- Subjects covered by Articles L. 1121-5, L. 1121-7, and L1121-8 of the Public Health Code.
- Pregnant women, women in labor, or breastfeeding mothers.
- Subjects subject to legal protection measures (guardianship, curatorship, judicial protection).
- Subjects unable to give their consent.
- Subjects deprived of their liberty by a judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L.3213-1.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: VERITON-CT New
Optimized collimators for the CZT detectors of the VERITON™ 400 wide-field camera (Spectrum Dynamics Medical) enabling better selection of incident photons
|
- Whole-body 3D recording on the VERITON™ 400 camera equipped with conventional collimators for technetium-99m and lutetium-177.
|
|
Comparateur actif: Référence
|
Full-body 3D recording on the VERITON™ 400 camera
Whole-body 2D and cervicothoracic 3D recordings using an Anger camera (SYMBIA camera, Siemens Healthineers) for iodine-131 images.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Feasability of whole-body SPECT/CT imaging with iodine-131 using the optimized collimator
Délai: 1 month
|
Data analysis obtained with optimized collimator and with conventional collimator
|
1 month
|
|
Perform quantitative analysis of technetium-99m and lutetium-177 with feasability results
Délai: 1 month
|
Image sharpness improvment
|
1 month
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Overall quality of whole-body CZT acquisitions with iodine-131
Délai: 1 month
|
For iodine-131, the overall quality of images acquired using the CZT-SPECT camera with the new collimator will be described based on an ordinal score for stellar artifacts (absent, present but not interfering, present and interfering), assessed independently by two experienced readers.
The frequency and severity of artifacts will be reported, as well as their association with the interpretable or non-interpretable nature of the examinations defined in the primary endpoint.
Inter-reader agreement will also be described.
|
1 month
|
|
Quantify the detectability and contrast of lesions visualized on whole-body CZT imaging with iodine-131.
Délai: 1 month
|
Sharpness, defined as the maximum slope of the intensity profile at the edge of the lesions and the contrast-to-noise ratio
|
1 month
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 2026-A00456-45
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .