- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07589426
Horizontal Ridge Augmentation in Maxillary Esthetic Zone Using Bovine Bone Graft Versus Extended Sticky Bone With Simultaneous Implant Placement
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Patient selection This study will involve sixteen implants inserted in patients with missing upper tooth / teeth in the esthetic zone accompanied by horizontal alveolar ridge resorption, seeking future tooth replacement. The patients will be selected from the Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Mansoura University
Inclusion Criteria:
- Patient aged 18-45 years.
- Cooperative patient with high motivation and acceptable oral hygiene.
- Maxillary narrow ridge in the esthetic zone that needed horizontal bone augmentation. (Class I Siebert classification). (22)
- No deep undercut at the ridge in the buccal aspect.
- The presence of enough keratinized gingiva(≥3mm).(23)
- Sufficient inter-arch space to accommodate the future prosthesis. (24)
- Patients able to comply with the required recall visits.
Exclusion criteria:
- Local and / or systemic conditions that contraindicate the placement of dental implant or surgery
- Smokers
- Pregnancy.
- Parafunctional habits, including bruxism and clenching.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Al Mansurah, Egypte
- Mansoura University
-
Al Mansurah, Egypte
- Amira Attia
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
Accepte les volontaires sains
La description
Inclusion Criteria:
- Patient aged 18-45 years, Cooperative patient with high motivation and acceptable oral hygiene, maxillary narrow ridge in the esthetic zone that needed horizontal bone augmentation. (Class I Siebert classification) (24),No deep undercut at the ridge in the buccal aspect, The presence of enough keratinized gingiva(≥3mm).(25), sufficient inter-arch space to accommodate the future prosthesis. (26) , and Patients able to comply with the required recall visits.
Exclusion Criteria:
- Local and / or systemic conditions that contraindicate the placement of dental implant or surgery, smokers, pregnancy and parafunctional habits, including bruxism and clenching.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Eight dental implants were inserted simultaneously with horizontal ridge augmentation using Medpark
For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site.
For group II, extended sticky bone (ESB) was prepared by centrifugation of autologous blood followed by preparation of ALB-PRF and mixing with bone particulates (50:50 allograft: xenograft) to obtain the final graft materia
|
The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. (Fig.1B & Fig.2B) Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b |
|
Expérimental: Eight dental implants were inserted simultaneously with horizontal ridge augmentation using extended
|
The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. (Fig.1B & Fig.2B) Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Implant Stability Quotient (ISQ) Values Assessed by Resonance Frequency Analysis
Délai: Baseline and 6 months after implant placement
|
Implant stability was assessed using resonance frequency analysis (RFA) with the Osstell device and expressed as Implant Stability Quotient (ISQ) values. ISQ scores range from 1 to 100, with higher scores indicating greater implant stability and osseointegration. High stability: ISQ > 70 Medium stability: ISQ 60-69 Low stability: ISQ < 60 Measurements were recorded immediately after implant placement and at the 6-month follow-up. |
Baseline and 6 months after implant placement
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- Ms.25.04.21
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .