- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT07589426
Horizontal Ridge Augmentation in Maxillary Esthetic Zone Using Bovine Bone Graft Versus Extended Sticky Bone With Simultaneous Implant Placement
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
Patient selection This study will involve sixteen implants inserted in patients with missing upper tooth / teeth in the esthetic zone accompanied by horizontal alveolar ridge resorption, seeking future tooth replacement. The patients will be selected from the Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Mansoura University
Inclusion Criteria:
- Patient aged 18-45 years.
- Cooperative patient with high motivation and acceptable oral hygiene.
- Maxillary narrow ridge in the esthetic zone that needed horizontal bone augmentation. (Class I Siebert classification). (22)
- No deep undercut at the ridge in the buccal aspect.
- The presence of enough keratinized gingiva(≥3mm).(23)
- Sufficient inter-arch space to accommodate the future prosthesis. (24)
- Patients able to comply with the required recall visits.
Exclusion criteria:
- Local and / or systemic conditions that contraindicate the placement of dental implant or surgery
- Smokers
- Pregnancy.
- Parafunctional habits, including bruxism and clenching.
Tanulmány típusa
Beiratkozás (Tényleges)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
-
Al Mansurah, Egyiptom
- Mansoura University
-
Al Mansurah, Egyiptom
- Amira Attia
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
- Felnőtt
Egészséges önkénteseket fogad
Leírás
Inclusion Criteria:
- Patient aged 18-45 years, Cooperative patient with high motivation and acceptable oral hygiene, maxillary narrow ridge in the esthetic zone that needed horizontal bone augmentation. (Class I Siebert classification) (24),No deep undercut at the ridge in the buccal aspect, The presence of enough keratinized gingiva(≥3mm).(25), sufficient inter-arch space to accommodate the future prosthesis. (26) , and Patients able to comply with the required recall visits.
Exclusion Criteria:
- Local and / or systemic conditions that contraindicate the placement of dental implant or surgery, smokers, pregnancy and parafunctional habits, including bruxism and clenching.
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Kezelés
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Egyetlen
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: Eight dental implants were inserted simultaneously with horizontal ridge augmentation using Medpark
For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site.
For group II, extended sticky bone (ESB) was prepared by centrifugation of autologous blood followed by preparation of ALB-PRF and mixing with bone particulates (50:50 allograft: xenograft) to obtain the final graft materia
|
The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. (Fig.1B & Fig.2B) Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b |
|
Kísérleti: Eight dental implants were inserted simultaneously with horizontal ridge augmentation using extended
|
The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. (Fig.1B & Fig.2B) Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b |
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Implant Stability Quotient (ISQ) Values Assessed by Resonance Frequency Analysis
Időkeret: Baseline and 6 months after implant placement
|
Implant stability was assessed using resonance frequency analysis (RFA) with the Osstell device and expressed as Implant Stability Quotient (ISQ) values. ISQ scores range from 1 to 100, with higher scores indicating greater implant stability and osseointegration. High stability: ISQ > 70 Medium stability: ISQ 60-69 Low stability: ISQ < 60 Measurements were recorded immediately after implant placement and at the 6-month follow-up. |
Baseline and 6 months after implant placement
|
Együttműködők és nyomozók
Szponzor
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- Ms.25.04.21
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .