- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07589426
Horizontal Ridge Augmentation in Maxillary Esthetic Zone Using Bovine Bone Graft Versus Extended Sticky Bone With Simultaneous Implant Placement
Studieoversikt
Status
Intervensjon / Behandling
Detaljert beskrivelse
Patient selection This study will involve sixteen implants inserted in patients with missing upper tooth / teeth in the esthetic zone accompanied by horizontal alveolar ridge resorption, seeking future tooth replacement. The patients will be selected from the Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Mansoura University
Inclusion Criteria:
- Patient aged 18-45 years.
- Cooperative patient with high motivation and acceptable oral hygiene.
- Maxillary narrow ridge in the esthetic zone that needed horizontal bone augmentation. (Class I Siebert classification). (22)
- No deep undercut at the ridge in the buccal aspect.
- The presence of enough keratinized gingiva(≥3mm).(23)
- Sufficient inter-arch space to accommodate the future prosthesis. (24)
- Patients able to comply with the required recall visits.
Exclusion criteria:
- Local and / or systemic conditions that contraindicate the placement of dental implant or surgery
- Smokers
- Pregnancy.
- Parafunctional habits, including bruxism and clenching.
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Al Mansurah, Egypt
- Mansoura University
-
Al Mansurah, Egypt
- Amira Attia
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Voksen
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- Patient aged 18-45 years, Cooperative patient with high motivation and acceptable oral hygiene, maxillary narrow ridge in the esthetic zone that needed horizontal bone augmentation. (Class I Siebert classification) (24),No deep undercut at the ridge in the buccal aspect, The presence of enough keratinized gingiva(≥3mm).(25), sufficient inter-arch space to accommodate the future prosthesis. (26) , and Patients able to comply with the required recall visits.
Exclusion Criteria:
- Local and / or systemic conditions that contraindicate the placement of dental implant or surgery, smokers, pregnancy and parafunctional habits, including bruxism and clenching.
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Eight dental implants were inserted simultaneously with horizontal ridge augmentation using Medpark
For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site.
For group II, extended sticky bone (ESB) was prepared by centrifugation of autologous blood followed by preparation of ALB-PRF and mixing with bone particulates (50:50 allograft: xenograft) to obtain the final graft materia
|
The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. (Fig.1B & Fig.2B) Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b |
|
Eksperimentell: Eight dental implants were inserted simultaneously with horizontal ridge augmentation using extended
|
The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b The oral cavity was prepared using 0.12% chlorhexidine mouth rinse for one minute. Local anesthesia was administered using articaine 4% with 1:100,000 epinephrine. A full-thickness mucoperiosteal flap was reflected using a crestal horizontal incision with vertical releasing incisions to expose the surgical site. Osteotomy preparation was performed using a pilot drill to the planned depth at 800-850 rpm under copious sterile saline irrigation, followed by sequential drilling according to the manufacturer's protocol until the final implant size was achieved. The sterile implant was then inserted using a ratchet wrench. (Fig.1B & Fig.2B) Implant stability was immediately assessed using resonance frequency analysis (Osstell device), and cover screws were subsequently placed. For group I, Medpark bone graft was prepared by hydration with sterile saline, gentle mixing, and allowed to partially set before application to the defect site. For group II, extended sticky bone (ESB) was prepared b |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Implant Stability Quotient (ISQ) Values Assessed by Resonance Frequency Analysis
Tidsramme: Baseline and 6 months after implant placement
|
Implant stability was assessed using resonance frequency analysis (RFA) with the Osstell device and expressed as Implant Stability Quotient (ISQ) values. ISQ scores range from 1 to 100, with higher scores indicating greater implant stability and osseointegration. High stability: ISQ > 70 Medium stability: ISQ 60-69 Low stability: ISQ < 60 Measurements were recorded immediately after implant placement and at the 6-month follow-up. |
Baseline and 6 months after implant placement
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- Ms.25.04.21
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .