- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07649720
NaviCam Patency Capsule to Verify Gastrointestinal Patency (PATENCY)
A Prospective, Single Center Clinical Trial Assessing the Efficacy and Safety of the NaviCam Patency Capsule to Verify Gastrointestinal Patency
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
If the X-ray scan indicates that the capsule is not in the body or shows that the patency capsule is in the colonic area or if an intact patency capsule is found in the bowel movement, it proves that the intestine is patent, and the patient can undergo an examination using capsule endoscopy. If the X-ray scan shows that the capsule is still in the small bowel area, it indicates that there may be stricture(s) in the intestines, and then small bowel capsule endoscopy may not be performed.
The patency capsule is a disposable medical device composed of medicinal excipients in the shape of a dissolvable passive capsule and will dissolve over time if not excreted.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Tim Thomas, RAC
- Numéro de téléphone: 770-480-2911
- E-mail: tim.thomas@anxrobotics.com
Lieux d'étude
-
-
Illinois
-
Downers Grove, Illinois, États-Unis, 60515
- Digestive Health Services
-
Contact:
- Rockford G Yapp, MD
- Numéro de téléphone: 630-297-9474
- E-mail: rockford.g.yapp3@gmail.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Patients with suspected or known intestinal stricture (with medical history records, physical examination records, and imaging evidence within the last 6 months.
- Patients suffering from Crohn's Disease
- Patients with long-term use of non-steroidal anti-inflammatory drugs.
- Patients with abdominal symptoms related to intestinal stricture.
- Patients with chronic inflammatory diseases.
- Patients with difficulty with balloon-assisted endoscopy (BAE).
- Patients with a history of small bowel obstruction.
- Patients with a history of intestinal resection surgery.
Exclusion Criteria:
- Patients with esophageal obstruction or swallowing disorder diseases.
- Patients who are ineligible for surgery or refuse to undergo any abdominal surgery.
- Patients with known allergies or other contraindications or intolerance to the medications used in this study.
- Patients with pacemakers or other implanted electronic devices such as cochlear implants, magnetic metal drug infusion pumps, neurostimulators.
- Pregnant women
- Patients currently enrolled in another drug or device clinical trial.
- Other conditions deemed unsuitable for inclusion by the investigator.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Dépistage
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Single arm patency capsule evaluation
Participants will first swallow a patency capsule and then undergo an abdominal X-ray scan within 30 hours after swallowing the capsule to confirm whether the capsule is still in the body.
|
The NaviCam Patency Capsule is an accessory to the NaviCam capsule and is intended to verify adequate patency of the gastrointestinal tract prior to administration of the NaviCam capsule in patients with known or suspected strictures.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Safety of patency capsule
Délai: 30 hours
|
The number of patients successfully passing the Patency Capsule within 30 hours compared to the number of patients where the Patency Capsule dissolves in patients with strictures.
|
30 hours
|
|
Efficacy of patency capsule
Délai: 30 hours
|
The percentage of patients that successfully pass the Patency capsule within 30 hours.
|
30 hours
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Rockford G Yapp, MD, Digestive Health Services
Publications et liens utiles
Publications générales
- Herrerias JM, Leighton JA, Costamagna G, Infantolino A, Eliakim R, Fischer D, Rubin DT, Manten HD, Scapa E, Morgan DR, Bergwerk AJ, Koslowsky B, Adler SN. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy. Gastrointest Endosc. 2008 May;67(6):902-9. doi: 10.1016/j.gie.2007.10.063. Epub 2008 Mar 19.
- Takeda K, Tashimo H, Miyakawa K, Shimada M, Ohshima N, Tamura A, Nagai H, Matsui H. Patency Capsule Aspiration. Intern Med. 2020 Apr 15;59(8):1071-1073. doi: 10.2169/internalmedicine.4012-19. Epub 2020 Jan 9.
- Okoli A, Ammannagari N, Mazumder M, Nakkala K. When the dissolvable does not dissolve: an agile patency capsule mystery. Am J Gastroenterol. 2014 Apr;109(4):605-7. doi: 10.1038/ajg.2013.435. No abstract available.
- Mitselos IV, Katsanos K, Tsianos EV, Eliakim R, Christodoulou D. Clinical Use of Patency Capsule: A Comprehensive Review of the Literature. Inflamm Bowel Dis. 2018 Oct 12;24(11):2339-2347. doi: 10.1093/ibd/izy152.
- Spada C, Shah SK, Riccioni ME, Spera G, Marchese M, Iacopini F, Familiari P, Costamagna G. Video capsule endoscopy in patients with known or suspected small bowel stricture previously tested with the dissolving patency capsule. J Clin Gastroenterol. 2007 Jul;41(6):576-82. doi: 10.1097/01.mcg.0000225633.14663.64.
- Kopylov U, Nemeth A, Cebrian A, Wurm Johansson G, Thorlacius H, Fernandez-Urien Sainz I, Koulaouzidis A, Eliakim R, Toth E. Symptomatic retention of the patency capsule: a multicenter real life case series. Endosc Int Open. 2016 Sep;4(9):E964-9. doi: 10.1055/s-0042-112588. Epub 2016 Aug 8.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- La douleur
- Manifestations neurologiques
- Signes et symptômes digestifs
- Maladies intestinales
- Maladies du système digestif
- Maladies gastro-intestinales
- Gastro-entérite
- Maladies intestinales inflammatoires
- Conditions pathologiques, signes et symptômes
- Signes et symptômes
- Douleur abdominale
- Maladie de Crohn
Autres numéros d'identification d'étude
- P11_CEP-0001
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .