- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07755722
Effect of Head Turn on Double-Lumen Tube Alignment
The Efficacy of Right Displacement of Trachea on Double Lumen Tube Intubation Under Fiberscope
This study evaluated how simple external airway maneuvers affect the alignment of the left main bronchus during placement of a left-sided double-lumen endotracheal tube. Adults undergoing elective thoracic surgery requiring one-lung ventilation were enrolled.
During double-lumen tube placement, a fiberoptic bronchoscope was used to continuously view the airway. Each participant underwent three sequential maneuvers: rightward displacement of the trachea, turning the head 45 degrees to the right, and turning the head 45 degrees to the left. The investigators measured how far the opening of the left main bronchus moved on the bronchoscopic image and whether it crossed the center of the image.
The purpose of the study was to determine how these maneuvers change airway alignment and whether they may help guide a left-sided double-lumen tube toward the left main bronchus.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Taipei, Taïwan, 11217
- Taipei Veterans General Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Patients scheduled for elective thoracic surgery requiring lung isolation with a left-sided double-lumen endotracheal tube
- American Society of Anesthesiologists (ASA) physical status I-III
- Provided written informed consent
Exclusion Criteria:
- Known severe cervical spine pathology or cervical instability
- History of cervical spine surgery
- Significant anatomical abnormalities of the upper airway
- Head or neck malignancy or obstructing airway neoplasm
- Presence of a tracheostomy
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Science basique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Airway Maneuver Group
Participants underwent three airway maneuvers in a predefined sequence during left-sided double-lumen tube placement: right tracheal displacement, 45° right head turn, and 45° left head turn.
The airway and head position were returned to neutral between maneuvers.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during each maneuver.
|
A lateral force was applied externally at the left cricothyroid level to displace the trachea toward the right.
The force was increased until maximal bronchoscopic displacement was observed.
Peak applied force was recorded using a digital force gauge.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The participant's head was rotated 45° to the right from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
The participant's head was rotated 45° to the left from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Midline Crossing of the Left Main Bronchus
Délai: During the airway maneuver, immediately after each maneuver was applied
|
Midline crossing was defined as a change in the position of the left main bronchus from the left side to the right side of the midline of the bronchoscopic image following each airway maneuver.
The position of the left main bronchus was assessed using real-time fiberoptic bronchoscopy with the bronchoscope maintained 2 cm proximal to the carina.
Midline crossing was recorded as a binary outcome (yes/no) for each maneuver.
|
During the airway maneuver, immediately after each maneuver was applied
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Relative Horizontal Displacement of the Left Main Bronchus
Délai: During the airway maneuver, immediately after each maneuver was applied
|
Relative horizontal displacement was defined as the difference in the horizontal position of the left main bronchus before and during each airway maneuver, expressed as a percentage (Δ%) of the total width of the bronchoscopic image.
The right edge of the left main bronchus was used as the reference point.
Positive values indicated rightward displacement and negative values indicated leftward displacement.
Measurements were obtained from bronchoscopic images with the bronchoscope maintained 2 cm proximal to the carina.
|
During the airway maneuver, immediately after each maneuver was applied
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Chien-Kun Ting, MD, PhD, Taipei Veterans General Hospital, Taiwan
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- 2023-12-003BCF
- V115C-038 (Autre subvention/numéro de financement: Taipei Veterans General Hospital)
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Délai de partage IPD
Critères d'accès au partage IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .