- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07755722
Effect of Head Turn on Double-Lumen Tube Alignment
The Efficacy of Right Displacement of Trachea on Double Lumen Tube Intubation Under Fiberscope
This study evaluated how simple external airway maneuvers affect the alignment of the left main bronchus during placement of a left-sided double-lumen endotracheal tube. Adults undergoing elective thoracic surgery requiring one-lung ventilation were enrolled.
During double-lumen tube placement, a fiberoptic bronchoscope was used to continuously view the airway. Each participant underwent three sequential maneuvers: rightward displacement of the trachea, turning the head 45 degrees to the right, and turning the head 45 degrees to the left. The investigators measured how far the opening of the left main bronchus moved on the bronchoscopic image and whether it crossed the center of the image.
The purpose of the study was to determine how these maneuvers change airway alignment and whether they may help guide a left-sided double-lumen tube toward the left main bronchus.
Studie Overzicht
Toestand
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Taipei, Taiwan, 11217
- Taipei Veterans General Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Patients scheduled for elective thoracic surgery requiring lung isolation with a left-sided double-lumen endotracheal tube
- American Society of Anesthesiologists (ASA) physical status I-III
- Provided written informed consent
Exclusion Criteria:
- Known severe cervical spine pathology or cervical instability
- History of cervical spine surgery
- Significant anatomical abnormalities of the upper airway
- Head or neck malignancy or obstructing airway neoplasm
- Presence of a tracheostomy
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Fundamentele wetenschap
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Airway Maneuver Group
Participants underwent three airway maneuvers in a predefined sequence during left-sided double-lumen tube placement: right tracheal displacement, 45° right head turn, and 45° left head turn.
The airway and head position were returned to neutral between maneuvers.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during each maneuver.
|
A lateral force was applied externally at the left cricothyroid level to displace the trachea toward the right.
The force was increased until maximal bronchoscopic displacement was observed.
Peak applied force was recorded using a digital force gauge.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The participant's head was rotated 45° to the right from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
The participant's head was rotated 45° to the left from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Midline Crossing of the Left Main Bronchus
Tijdsspanne: During the airway maneuver, immediately after each maneuver was applied
|
Midline crossing was defined as a change in the position of the left main bronchus from the left side to the right side of the midline of the bronchoscopic image following each airway maneuver.
The position of the left main bronchus was assessed using real-time fiberoptic bronchoscopy with the bronchoscope maintained 2 cm proximal to the carina.
Midline crossing was recorded as a binary outcome (yes/no) for each maneuver.
|
During the airway maneuver, immediately after each maneuver was applied
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Relative Horizontal Displacement of the Left Main Bronchus
Tijdsspanne: During the airway maneuver, immediately after each maneuver was applied
|
Relative horizontal displacement was defined as the difference in the horizontal position of the left main bronchus before and during each airway maneuver, expressed as a percentage (Δ%) of the total width of the bronchoscopic image.
The right edge of the left main bronchus was used as the reference point.
Positive values indicated rightward displacement and negative values indicated leftward displacement.
Measurements were obtained from bronchoscopic images with the bronchoscope maintained 2 cm proximal to the carina.
|
During the airway maneuver, immediately after each maneuver was applied
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Chien-Kun Ting, MD, PhD, Taipei Veterans General Hospital, Taiwan
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- 2023-12-003BCF
- V115C-038 (Ander subsidie-/financieringsnummer: Taipei Veterans General Hospital)
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
IPD-tijdsbestek voor delen
IPD-toegangscriteria voor delen
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .