Effect of Head Turn on Double-Lumen Tube Alignment
The Efficacy of Right Displacement of Trachea on Double Lumen Tube Intubation Under Fiberscope
This study evaluated how simple external airway maneuvers affect the alignment of the left main bronchus during placement of a left-sided double-lumen endotracheal tube. Adults undergoing elective thoracic surgery requiring one-lung ventilation were enrolled.
During double-lumen tube placement, a fiberoptic bronchoscope was used to continuously view the airway. Each participant underwent three sequential maneuvers: rightward displacement of the trachea, turning the head 45 degrees to the right, and turning the head 45 degrees to the left. The investigators measured how far the opening of the left main bronchus moved on the bronchoscopic image and whether it crossed the center of the image.
The purpose of the study was to determine how these maneuvers change airway alignment and whether they may help guide a left-sided double-lumen tube toward the left main bronchus.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Taipei, Taiwan, 11217
- Taipei Veterans General Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Patients scheduled for elective thoracic surgery requiring lung isolation with a left-sided double-lumen endotracheal tube
- American Society of Anesthesiologists (ASA) physical status I-III
- Provided written informed consent
Exclusion Criteria:
- Known severe cervical spine pathology or cervical instability
- History of cervical spine surgery
- Significant anatomical abnormalities of the upper airway
- Head or neck malignancy or obstructing airway neoplasm
- Presence of a tracheostomy
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Scienza basilare
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Airway Maneuver Group
Participants underwent three airway maneuvers in a predefined sequence during left-sided double-lumen tube placement: right tracheal displacement, 45° right head turn, and 45° left head turn.
The airway and head position were returned to neutral between maneuvers.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during each maneuver.
|
A lateral force was applied externally at the left cricothyroid level to displace the trachea toward the right.
The force was increased until maximal bronchoscopic displacement was observed.
Peak applied force was recorded using a digital force gauge.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The participant's head was rotated 45° to the right from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
The participant's head was rotated 45° to the left from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Midline Crossing of the Left Main Bronchus
Lasso di tempo: During the airway maneuver, immediately after each maneuver was applied
|
Midline crossing was defined as a change in the position of the left main bronchus from the left side to the right side of the midline of the bronchoscopic image following each airway maneuver.
The position of the left main bronchus was assessed using real-time fiberoptic bronchoscopy with the bronchoscope maintained 2 cm proximal to the carina.
Midline crossing was recorded as a binary outcome (yes/no) for each maneuver.
|
During the airway maneuver, immediately after each maneuver was applied
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Relative Horizontal Displacement of the Left Main Bronchus
Lasso di tempo: During the airway maneuver, immediately after each maneuver was applied
|
Relative horizontal displacement was defined as the difference in the horizontal position of the left main bronchus before and during each airway maneuver, expressed as a percentage (Δ%) of the total width of the bronchoscopic image.
The right edge of the left main bronchus was used as the reference point.
Positive values indicated rightward displacement and negative values indicated leftward displacement.
Measurements were obtained from bronchoscopic images with the bronchoscope maintained 2 cm proximal to the carina.
|
During the airway maneuver, immediately after each maneuver was applied
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Chien-Kun Ting, MD, PhD, Taipei Veterans General Hospital, Taiwan
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- 2023-12-003BCF
- V115C-038 (Altro numero di sovvenzione/finanziamento: Taipei Veterans General Hospital)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Periodo di condivisione IPD
Criteri di accesso alla condivisione IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .