Effect of Head Turn on Double-Lumen Tube Alignment
The Efficacy of Right Displacement of Trachea on Double Lumen Tube Intubation Under Fiberscope
This study evaluated how simple external airway maneuvers affect the alignment of the left main bronchus during placement of a left-sided double-lumen endotracheal tube. Adults undergoing elective thoracic surgery requiring one-lung ventilation were enrolled.
During double-lumen tube placement, a fiberoptic bronchoscope was used to continuously view the airway. Each participant underwent three sequential maneuvers: rightward displacement of the trachea, turning the head 45 degrees to the right, and turning the head 45 degrees to the left. The investigators measured how far the opening of the left main bronchus moved on the bronchoscopic image and whether it crossed the center of the image.
The purpose of the study was to determine how these maneuvers change airway alignment and whether they may help guide a left-sided double-lumen tube toward the left main bronchus.
Descripción general del estudio
Estado
Condiciones
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Taipei, Taiwán, 11217
- Taipei Veterans General Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Patients scheduled for elective thoracic surgery requiring lung isolation with a left-sided double-lumen endotracheal tube
- American Society of Anesthesiologists (ASA) physical status I-III
- Provided written informed consent
Exclusion Criteria:
- Known severe cervical spine pathology or cervical instability
- History of cervical spine surgery
- Significant anatomical abnormalities of the upper airway
- Head or neck malignancy or obstructing airway neoplasm
- Presence of a tracheostomy
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Airway Maneuver Group
Participants underwent three airway maneuvers in a predefined sequence during left-sided double-lumen tube placement: right tracheal displacement, 45° right head turn, and 45° left head turn.
The airway and head position were returned to neutral between maneuvers.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during each maneuver.
|
A lateral force was applied externally at the left cricothyroid level to displace the trachea toward the right.
The force was increased until maximal bronchoscopic displacement was observed.
Peak applied force was recorded using a digital force gauge.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The participant's head was rotated 45° to the right from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
The participant's head was rotated 45° to the left from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Midline Crossing of the Left Main Bronchus
Periodo de tiempo: During the airway maneuver, immediately after each maneuver was applied
|
Midline crossing was defined as a change in the position of the left main bronchus from the left side to the right side of the midline of the bronchoscopic image following each airway maneuver.
The position of the left main bronchus was assessed using real-time fiberoptic bronchoscopy with the bronchoscope maintained 2 cm proximal to the carina.
Midline crossing was recorded as a binary outcome (yes/no) for each maneuver.
|
During the airway maneuver, immediately after each maneuver was applied
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Relative Horizontal Displacement of the Left Main Bronchus
Periodo de tiempo: During the airway maneuver, immediately after each maneuver was applied
|
Relative horizontal displacement was defined as the difference in the horizontal position of the left main bronchus before and during each airway maneuver, expressed as a percentage (Δ%) of the total width of the bronchoscopic image.
The right edge of the left main bronchus was used as the reference point.
Positive values indicated rightward displacement and negative values indicated leftward displacement.
Measurements were obtained from bronchoscopic images with the bronchoscope maintained 2 cm proximal to the carina.
|
During the airway maneuver, immediately after each maneuver was applied
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Chien-Kun Ting, MD, PhD, Taipei Veterans General Hospital, Taiwan
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 2023-12-003BCF
- V115C-038 (Otro número de subvención/financiamiento: Taipei Veterans General Hospital)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Marco de tiempo para compartir IPD
Criterios de acceso compartido de IPD
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .