- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07755722
Effect of Head Turn on Double-Lumen Tube Alignment
The Efficacy of Right Displacement of Trachea on Double Lumen Tube Intubation Under Fiberscope
This study evaluated how simple external airway maneuvers affect the alignment of the left main bronchus during placement of a left-sided double-lumen endotracheal tube. Adults undergoing elective thoracic surgery requiring one-lung ventilation were enrolled.
During double-lumen tube placement, a fiberoptic bronchoscope was used to continuously view the airway. Each participant underwent three sequential maneuvers: rightward displacement of the trachea, turning the head 45 degrees to the right, and turning the head 45 degrees to the left. The investigators measured how far the opening of the left main bronchus moved on the bronchoscopic image and whether it crossed the center of the image.
The purpose of the study was to determine how these maneuvers change airway alignment and whether they may help guide a left-sided double-lumen tube toward the left main bronchus.
Visão geral do estudo
Status
Condições
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Taipei, Taiwan, 11217
- Taipei Veterans General Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Patients scheduled for elective thoracic surgery requiring lung isolation with a left-sided double-lumen endotracheal tube
- American Society of Anesthesiologists (ASA) physical status I-III
- Provided written informed consent
Exclusion Criteria:
- Known severe cervical spine pathology or cervical instability
- History of cervical spine surgery
- Significant anatomical abnormalities of the upper airway
- Head or neck malignancy or obstructing airway neoplasm
- Presence of a tracheostomy
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Ciência básica
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Airway Maneuver Group
Participants underwent three airway maneuvers in a predefined sequence during left-sided double-lumen tube placement: right tracheal displacement, 45° right head turn, and 45° left head turn.
The airway and head position were returned to neutral between maneuvers.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during each maneuver.
|
A lateral force was applied externally at the left cricothyroid level to displace the trachea toward the right.
The force was increased until maximal bronchoscopic displacement was observed.
Peak applied force was recorded using a digital force gauge.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The participant's head was rotated 45° to the right from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
The participant's head was rotated 45° to the left from the neutral position.
Bronchoscopic alignment and horizontal displacement of the left main bronchus were assessed during the maneuver.
The head was subsequently returned to the neutral position.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Midline Crossing of the Left Main Bronchus
Prazo: During the airway maneuver, immediately after each maneuver was applied
|
Midline crossing was defined as a change in the position of the left main bronchus from the left side to the right side of the midline of the bronchoscopic image following each airway maneuver.
The position of the left main bronchus was assessed using real-time fiberoptic bronchoscopy with the bronchoscope maintained 2 cm proximal to the carina.
Midline crossing was recorded as a binary outcome (yes/no) for each maneuver.
|
During the airway maneuver, immediately after each maneuver was applied
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Relative Horizontal Displacement of the Left Main Bronchus
Prazo: During the airway maneuver, immediately after each maneuver was applied
|
Relative horizontal displacement was defined as the difference in the horizontal position of the left main bronchus before and during each airway maneuver, expressed as a percentage (Δ%) of the total width of the bronchoscopic image.
The right edge of the left main bronchus was used as the reference point.
Positive values indicated rightward displacement and negative values indicated leftward displacement.
Measurements were obtained from bronchoscopic images with the bronchoscope maintained 2 cm proximal to the carina.
|
During the airway maneuver, immediately after each maneuver was applied
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Chien-Kun Ting, MD, PhD, Taipei Veterans General Hospital, Taiwan
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- 2023-12-003BCF
- V115C-038 (Número de outro subsídio/financiamento: Taipei Veterans General Hospital)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Prazo de Compartilhamento de IPD
Critérios de acesso de compartilhamento IPD
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .